Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Am Heart Assoc ; 7(7)2018 03 26.
Article in English | MEDLINE | ID: mdl-29581222

ABSTRACT

BACKGROUND: Primary prevention implantable cardioverter-defibrillators (ICDs) reduce mortality in selected patients with left ventricular systolic dysfunction by delivering therapies (antitachycardia pacing or shocks) to terminate potentially lethal arrhythmias; inappropriate therapies also occur. We assessed device therapies among adults receiving primary prevention ICDs in 7 healthcare systems. METHODS AND RESULTS: We linked medical record data, adjudicated device therapies, and the National Cardiovascular Data Registry ICD Registry. Survival analysis evaluated therapy probability and predictors after ICD implant from 2006 to 2009, with attention to Centers for Medicare and Medicaid Services Coverage With Evidence Development subgroups: left ventricular ejection fraction, 31% to 35%; nonischemic cardiomyopathy <9 months' duration; and New York Heart Association class IV heart failure with cardiac resynchronization therapy defibrillator. Among 2540 patients, 35% were <65 years old, 26% were women, and 59% were white. During 27 (median) months, 738 (29%) received ≥1 therapy. Three-year therapy risk was 36% (appropriate, 24%; inappropriate, 12%). Appropriate therapy was more common in men (adjusted hazard ratio [HR], 1.84; 95% confidence interval [CI], 1.43-2.35). Inappropriate therapy was more common in patients with atrial fibrillation (adjusted HR, 2.20; 95% CI, 1.68-2.87), but less common among patients ≥65 years old versus younger (adjusted HR, 0.72; 95% CI, 0.54-0.95) and in recent implants (eg, in 2009 versus 2006; adjusted HR, 0.66; 95% CI, 0.46-0.95). In Centers for Medicare and Medicaid Services Coverage With Evidence Development analysis, inappropriate therapy was less common with cardiac resynchronization therapy defibrillator versus single chamber (adjusted HR, 0.55; 95% CI, 0.36-0.84); therapy risk did not otherwise differ for Centers for Medicare and Medicaid Services Coverage With Evidence Development subgroups. CONCLUSIONS: In this community cohort of primary prevention patients receiving ICD, therapy delivery varied across demographic and clinical characteristics, but did not differ meaningfully for Centers for Medicare and Medicaid Services Coverage With Evidence Development subgroups.


Subject(s)
Arrhythmias, Cardiac/prevention & control , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Electric Countershock/instrumentation , Primary Prevention/instrumentation , Ventricular Dysfunction, Left/therapy , Aged , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/mortality , Arrhythmias, Cardiac/physiopathology , Centers for Medicare and Medicaid Services, U.S. , Electric Countershock/adverse effects , Electric Countershock/mortality , Female , Heart Rate , Humans , Male , Middle Aged , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome , United States , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/mortality , Ventricular Dysfunction, Left/physiopathology , Ventricular Function, Left
2.
Circ Cardiovasc Qual Outcomes ; 5(6): e78-85, 2012 Nov.
Article in English | MEDLINE | ID: mdl-23170006

ABSTRACT

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) are increasingly used for primary prevention after randomized, controlled trials demonstrating that they reduce the risk of death in patients with left ventricular systolic dysfunction. The extent to which the clinical characteristics and long-term outcomes of unselected, community-based patients with left ventricular systolic dysfunction undergoing primary prevention ICD implantation in a real-world setting compare with those enrolled in the randomized, controlled trials is not well characterized. This study is being conducted to address these questions. METHODS AND RESULTS: The study cohort includes consecutive patients undergoing primary prevention ICD placement between January 1, 2006 and December 31, 2009 in 7 health plans. Baseline clinical characteristics were acquired from the National Cardiovascular Data Registry ICD Registry. Longitudinal data collection is underway, and will include hospitalization, mortality, and resource use from standardized health plan data archives. Data regarding ICD therapies will be obtained through chart abstraction and adjudicated by a panel of experts in device therapy. Compared with the populations of primary prevention ICD therapy randomized, controlled trials, the cohort (n=2621) is on average significantly older (by 2.5-6.5 years), more often female, more often from racial and ethnic minority groups, and has a higher burden of coexisting conditions. The cohort is similar, however, to a national population undergoing primary prevention ICD placement. CONCLUSIONS: Patients undergoing primary prevention ICD implantation in this study differ from those enrolled in the randomized, controlled trials that established the efficacy of ICDs. Understanding a broad range of health outcomes, including ICD therapies, will provide patients, clinicians, and policy makers with contemporary data to inform decision-making.


Subject(s)
Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Electric Countershock/instrumentation , Primary Prevention/methods , Ventricular Dysfunction, Left/therapy , Aged , Chi-Square Distribution , Death, Sudden, Cardiac/etiology , Electric Countershock/adverse effects , Electric Countershock/mortality , Female , Hospitalization , Humans , Longitudinal Studies , Male , Middle Aged , Registries , Research Design , Time Factors , Treatment Outcome , United States , Ventricular Dysfunction, Left/complications , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/mortality
SELECTION OF CITATIONS
SEARCH DETAIL
...