Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
J Pediatr ; 262: 113563, 2023 11.
Article in English | MEDLINE | ID: mdl-37329979

ABSTRACT

OBJECTIVE: To determine whether transcutaneous auricular vagus nerve stimulation (taVNS) paired with twice daily bottle feeding increases the volume of oral feeds and white matter neuroplasticity in term-age-equivalent infants failing oral feeds and determined to need a gastrostomy tube. STUDY DESIGN: In this prospective, open-label study, 21 infants received taVNS paired with 2 bottle feeds for 2 - 3 weeks (2x). We compared 1) increase oral feeding volumes with 2x taVNS and previously reported once daily taVNS (1x) to determine a dose response, 2) number of infants who attained full oral feeding volumes, and 3) diffusional kurtosis imaging and magnetic resonance spectroscopy before and after treatment by paired t tests. RESULTS: All 2x taVNS treated infants significantly increased their feeding volumes compared with 10 days before treatment. Over 50% of 2x taVNS infants achieved full oral feeds but in a shorter time than 1x cohort (median 7 days [2x], 12.5 days [1x], P < .05). Infants attaining full oral feeds showed greater increase in radial kurtosis in the right corticospinal tract at the cerebellar peduncle and external capsule. Notably, 75% of infants of diabetic mothers failed full oral feeds, and their glutathione concentrations in the basal ganglia, a measure of central nervous system oxidative stress, were significantly associated with feeding outcome. CONCLUSIONS: In infants with feeding difficulty, increasing the number of daily taVNS-paired feeding sessions to twice-daily significantly accelerates response time but not the overall response rate of treatment. taVNS was associated with white matter motor tract plasticity in infants able to attain full oral feeds. TRIAL REGISTRATION: Clinicaltrials.gov (NCT04643808).


Subject(s)
Transcutaneous Electric Nerve Stimulation , Vagus Nerve Stimulation , White Matter , Female , Humans , Infant , White Matter/diagnostic imaging , Vagus Nerve Stimulation/methods , Gastrostomy , Prospective Studies , Transcutaneous Electric Nerve Stimulation/methods , Vagus Nerve/physiology
3.
NPJ Microgravity ; 6: 26, 2020.
Article in English | MEDLINE | ID: mdl-33024819

ABSTRACT

We are just beginning to understand how spaceflight may impact brain function. As NASA proceeds with plans to send astronauts to the Moon and commercial space travel interest increases, it is critical to understand how the human brain and peripheral nervous system respond to zero gravity. Here, we developed and refined head-worn transcranial magnetic stimulation (TMS) systems capable of reliably and quickly determining the amount of electromagnetism each individual needs to detect electromyographic (EMG) threshold levels in the thumb (called the resting motor threshold (rMT)). We then collected rMTs in 10 healthy adult participants in the laboratory at baseline, and subsequently at three time points onboard an airplane: (T1) pre-flight at Earth gravity, (T2) during zero gravity periods induced by parabolic flight and (T3) post-flight at Earth gravity. Overall, the subjects required 12.6% less electromagnetism applied to the brain to cause thumb muscle activation during weightlessness compared to Earth gravity, suggesting neurophysiological changes occur during brief periods of zero gravity. We discuss several candidate explanations for this finding, including upward shift of the brain within the skull, acute increases in cortical excitability, changes in intracranial pressure, and diffuse spinal or neuromuscular system effects. All of these possible explanations warrant further study. In summary, we documented neurophysiological changes during brief episodes of zero gravity and thus highlighting the need for further studies of human brain function in altered gravity conditions to optimally prepare for prolonged microgravity exposure during spaceflight.

4.
Brain Stimul ; 13(6): 1805-1812, 2020.
Article in English | MEDLINE | ID: mdl-33127579

ABSTRACT

BACKGROUND: Transcranial focused ultrasound (tFUS) is a noninvasive brain stimulation method that may modulate deep brain structures. This study investigates whether sonication of the right anterior thalamus would modulate thermal pain thresholds in healthy individuals. METHODS: We enrolled 19 healthy individuals in this three-visit, double-blind, sham-controlled, crossover trial. Participants first underwent a structural MRI scan used solely for tFUS targeting. They then attended two identical experimental tFUS visits (counterbalanced by condition) at least one week apart. Within the MRI scanner, participants received two, 10-min sessions of either active or sham tFUS spread 10 min apart targeting the right anterior thalamus [fundamental frequency: 650 kHz, Pulse repetition frequency: 10 Hz, Pulse Width: 5 ms, Duty Cycle: 5%, Sonication Duration: 30s, Inter-Sonication Interval: 30 s, Number of Sonications: 10, ISPTA.0 995 mW/cm2, ISPTA.3 719 mW/cm2, Peak rarefactional pressure 0.72 MPa]. The primary outcome measure was quantitative sensory thresholding (QST), measuring sensory, pain, and tolerance thresholds to a thermal stimulus applied to the left forearm before and after right anterior thalamic tFUS. RESULTS: The right anterior thalamus was accurately sonicated in 17 of the 19 subjects. Thermal pain sensitivity was significantly attenuated after active tFUS. The pre-post x active-sham interaction was significant (F(1,245.95) = 4.03, p = .046). This interaction indicates that in the sham stimulation condition, thermal pain thresholds decreased 1.08 °C (SE = 0.28) pre-post session, but only decreased .51 °C (SE = 0.30) pre-post session in the active stimulation group. CONCLUSIONS: Two 10-min sessions of anterior thalamic tFUS induces antinociceptive effects in healthy individuals. Future studies should optimize the parameter space, dose and duration of this effect which may lead to multi-session tFUS interventions for pain disorders.


Subject(s)
Anterior Thalamic Nuclei/diagnostic imaging , Anterior Thalamic Nuclei/physiology , Magnetic Resonance Imaging/methods , Pain Threshold/physiology , Pain/diagnostic imaging , Sonication/methods , Adult , Cross-Over Studies , Double-Blind Method , Female , Humans , Male , Pain/physiopathology
5.
Brain Stimul ; 13(4): 961-969, 2020.
Article in English | MEDLINE | ID: mdl-32330607

ABSTRACT

BACKGROUND: Unique amongst brain stimulation tools, transcranial direct current stimulation (tDCS) currently lacks an easy or widely implemented method for individualizing dosage. OBJECTIVE: We developed a method of reverse-calculating electric-field (E-field) models based on Magnetic Resonance Imaging (MRI) scans that can estimate individualized tDCS dose. We also evaluated an MRI-free method of individualizing tDCS dose by measuring transcranial magnetic stimulation (TMS) motor threshold (MT) and single pulse, suprathreshold transcranial electrical stimulation (TES) MT and regressing it against E-field modeling. Key assumptions of reverse-calculation E-field modeling, including the size of region of interest (ROI) analysis and the linearity of multiple E-field models were also tested. METHODS: In 29 healthy adults, we acquired TMS MT, TES MT, and anatomical T1-weighted MPRAGE MRI scans with a fiducial marking the motor hotspot. We then computed a "reverse-calculated tDCS dose" of tDCS applied at the scalp needed to cause a 1.00 V/m E-field at the cortex. Finally, we examined whether the predicted E-field values correlated with each participant's measured TMS MT or TES MT. RESULTS: We were able to determine a reverse-calculated tDCS dose for each participant using a 5 × 5 x 5 voxel grid region of interest (ROI) approach (average = 6.03 mA, SD = 1.44 mA, range = 3.75-9.74 mA). The Transcranial Electrical Stimulation MT, but not the Transcranial Magnetic Stimulation MT, significantly correlated with the ROI-based reverse-calculated tDCS dose determined by E-field modeling (R2 = 0.45, p < 0.001). CONCLUSIONS: Reverse-calculation E-field modeling, alone or regressed against TES MT, shows promise as a method to individualize tDCS dose. The large range of the reverse-calculated tDCS doses between subjects underscores the likely need to individualize tDCS dose. Future research should further examine the use of TES MT to individually dose tDCS as an MRI-free method of dosing tDCS.


Subject(s)
Cerebral Cortex/physiology , Transcranial Direct Current Stimulation/methods , Transcranial Magnetic Stimulation/methods , Adult , Female , Humans , Magnetic Resonance Imaging/methods , Male , Models, Neurological , Patient-Specific Modeling
6.
Front Hum Neurosci ; 14: 77, 2020.
Article in English | MEDLINE | ID: mdl-32256328

ABSTRACT

Neonates born premature or who suffer brain injury at birth often have oral feeding dysfunction and do not meet oral intake requirements needed for discharge. Low oral intake volumes result in extended stays in the hospital (>2 months) and can lead to surgical implant and explant of a gastrostomy tube (G-tube). Prior work suggests pairing vagus nerve stimulation (VNS) with motor activity accelerates functional improvements after stroke, and transcutaneous auricular VNS (taVNS) has emerged as promising noninvasive form of VNS. Pairing taVNS with bottle-feeding rehabilitation may improve oromotor coordination and lead to improved oral intake volumes, ultimately avoiding the need for G-tube placement. We investigated whether taVNS paired with oromotor rehabilitation is tolerable and safe and facilitates motor learning in infants who have failed oral feeding. We enrolled 14 infants [11 premature and 3 hypoxic-ischemic encephalopathy (HIE)] who were slated for G-tube placement in a prospective, open-label study of taVNS-paired rehabilitation to increase feeding volumes. Once-daily taVNS was delivered to the left tragus during bottle feeding for 2 weeks, with optional extension. The primary outcome was attainment of oral feeding volumes and weight gain adequate for discharge without G-tube while also monitoring discomfort and heart rate (HR) as safety outcomes. We observed no adverse events related to stimulation, and stimulation-induced HR reductions were transient and safe and likely confirmed vagal engagement. Eight of 14 participants (57%) achieved adequate feeding volumes for discharge without G-tube (mean treatment length: 16 ± 6 days). We observed significant increases in feeding volume trajectories in responders compared with pre-stimulation (p < 0.05). taVNS-paired feeding rehabilitation appears safe and may improve oral feeding in infants with oromotor dyscoordination, increasing the rate of discharge without G-tube, warranting larger controlled trials.

7.
Autism Res ; 13(3): 346-351, 2020 03.
Article in English | MEDLINE | ID: mdl-31944611

ABSTRACT

Patients with autism spectrum disorder (ASD) are at high risk for comorbid major depressive disorder (MDD), which can severely impair functioning and quality of life. Repetitive transcranial magnetic stimulation (rTMS) is a noninvasive brain stimulation technique, which is Food and Drug Administration (FDA) cleared for the treatment of MDD in adults. Despite demonstrated efficacy in the treatment of depression, there are limited data on the use of rTMS in patients with ASD and comorbid MDD. We hypothesized that a standard rTMS protocol for MDD would reduce depressive symptoms for adults with ASD and MDD. Secondarily, we investigated whether this treatment would also reduce core ASD symptoms. Participants of 18-65 years old with ASD and MDD without any medication changes in the last month were eligible for this open-label trial. Participants underwent 25 sessions of rTMS (figure-of-eight coil, 100-120% resting motor threshold, 10 Hz, 3,000 pulses per session) applied to the left dorsolateral prefrontal cortex. Thirteen participants enrolled in the study, with two withdrawing due to tolerability, and one excluded from analysis. Overall, side effects were mild and rTMS was well tolerated. The Hamilton rating scale for depression (HAM-D17 ) improved 13.5 points (IQR 5-15), and 40% of participants achieved remission (HAM-D17 ≤ 7) after rTMS treatment. Informant clinical scales of core symptoms of autism also suggested improvement with rTMS, though no change was observed by the participants themselves. Thus, this open-label trial suggests that high-frequency rTMS is well tolerated by adults with autism and MDD, with improvement in depressive symptoms and possible effects on core autism symptoms. Autism Res 2020, 13: 346-351. © 2020 International Society for Autism Research,Wiley Periodicals, Inc. LAY SUMMARY: This study evaluated the safety and effects of repetitive transcranial magnetic stimulation (rTMS) on depression and autism symptoms in individuals with both major depressive disorder and autism spectrum disorder. rTMS was well tolerated by the participants, depression improved with treatment, and family members' assessment of autism symptoms improved as well. This study supports the need for further work to evaluate rTMS in individuals who have both autism and depression.


Subject(s)
Autism Spectrum Disorder/complications , Autism Spectrum Disorder/therapy , Depressive Disorder, Major/complications , Depressive Disorder, Major/therapy , Transcranial Magnetic Stimulation/methods , Adult , Feasibility Studies , Female , Humans , Male , Pilot Projects , Prospective Studies , Quality of Life , Treatment Outcome , Young Adult
9.
Brain Stimul ; 11(4): 699-708, 2018.
Article in English | MEDLINE | ID: mdl-29716843

ABSTRACT

BACKGROUND: Optimal parameters of transcutaneous auricular vagus nerve stimulation (taVNS) are still undetermined. Given the vagus nerve's role in regulating heart rate (HR), it is important to determine safety and HR effects of various taVNS parameters. OBJECTIVE: We conducted two sequential trials to systematically test the effects of various taVNS parameters on HR. METHODS: 15 healthy individuals participated in the initial two-visit, crossover exploratory trial, receiving either tragus (active) or earlobe (control) stimulation each visit. Nine stimulation blocks of varying parameters (pulse width: 100 µs, 200 µs, 500 µs; frequency: 1 Hz, 10 Hz, 25 Hz) were administered each visit. HR was recorded and analyzed for stimulation-induced changes. Using similar methods and the two best parameters from trial 1 (500µs 10 Hz and 500µs 25 Hz), 20 healthy individuals then participated in a follow-up confirmatory study. RESULTS: Trial 1- There was no overall effect of the nine conditions on HR during stimulation. However multivariate analysis revealed two parameters that significantly decreased HR during active stimulation compared to control (500µs 10 Hz and 500µs 25 Hz; p < 0.01). Additionally, active taVNS significantly attenuated overall sympathetic HR rebound (post-stimulation) compared to control (p < 0.001). Trial 2-For these two conditions, active taVNS significantly decreased HR compared to control (p = 0.02), with the strongest effects at 500µs 10 Hz (p = 0.032). CONCLUSION: These studies suggest that 60s blocks of tragus stimulation are safe, and some specific parameters modulate HR. Of the nine parameters studied, 500µs 10 Hz induced the greatest HR effects.


Subject(s)
Heart Rate , Transcutaneous Electric Nerve Stimulation/adverse effects , Vagus Nerve Stimulation/adverse effects , Adult , Humans , Male , Transcutaneous Electric Nerve Stimulation/methods , Vagus Nerve/physiology , Vagus Nerve Stimulation/methods
11.
J Cereb Blood Flow Metab ; 37(11): 3599-3614, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28090802

ABSTRACT

Clinical studies have revealed a strong link between increased burden of cerebral microinfarcts and risk for cognitive impairment. Since the sum of tissue damage incurred by microinfarcts is a miniscule percentage of total brain volume, we hypothesized that microinfarcts disrupt brain function beyond the injury site visible to histological or radiological examination. We tested this idea using a mouse model of microinfarcts, where single penetrating vessels that supply mouse cortex were occluded by targeted photothrombosis. We found that in vivo structural and diffusion MRI reliably reported the acute microinfarct core, based on spatial co-registrations with post-mortem stains of neuronal viability. Consistent with our hypothesis, c-Fos assays for neuronal activity and in vivo imaging of single vessel hemodynamics both reported functional deficits in viable peri-lesional tissues beyond the microinfarct core. We estimated that the volume of tissue with functional deficit in cortex was at least 12-fold greater than the volume of the microinfarct core. Impaired hemodynamic responses in peri-lesional tissues persisted at least 14 days, and were attributed to lasting deficits in neuronal circuitry or neurovascular coupling. These data show how individually miniscule microinfarcts could contribute to broader brain dysfunction during vascular cognitive impairment and dementia.


Subject(s)
Cerebral Infarction/psychology , Cognition Disorders/etiology , Cognition Disorders/psychology , Animals , Cerebral Cortex/diagnostic imaging , Cerebral Infarction/diagnostic imaging , Cerebrovascular Circulation , Cognition Disorders/diagnostic imaging , Immunohistochemistry , Intracranial Thrombosis/complications , Intracranial Thrombosis/diagnostic imaging , Intracranial Thrombosis/psychology , Magnetic Resonance Imaging , Mice , Mice, Inbred C57BL , Neurons/pathology , Physical Stimulation , Proto-Oncogene Proteins c-fos/biosynthesis , Synapses/pathology , Vibrissae
SELECTION OF CITATIONS
SEARCH DETAIL
...