Hypertension ; 71(5): 937-945, 2018 05.
Article in English | MEDLINE | ID: mdl-29555666

ABSTRACT

Current distance measurement techniques for pulse wave velocity (PWV) calculation are susceptible to intercenter variability. The aim of this study was to derive and validate a formula for this distance measurement. Based on carotid femoral distance in 1183 whole-body magnetic resonance angiograms, a formula was derived for calculating distance. This was compared with distance measurements in 128 whole-body magnetic resonance angiograms from a second study. The effects of recalculation of PWV using the new formula on association with risk factors, disease discrimination, and prediction of major adverse cardiovascular events were examined within 1242 participants from the multicenter SUMMIT study (Surrogate Markers of Micro- and Macrovascular Hard End-Points for Innovative Diabetes Tools) and 825 participants from the Caerphilly Prospective Study. The distance formula yielded a mean error of 7.8 mm (limits of agreement =-41.1 to 56.7 mm; P<0.001) compared with the second whole-body magnetic resonance angiogram group. Compared with an external distance measurement, the distance formula did not change associations between PWV and age, blood pressure, or creatinine (P<0.01) but did remove significant associations between PWV and body mass index (BMI). After accounting for differences in age, sex, and mean arterial pressure, intercenter differences in PWV persisted using the external distance measurement (F=4.6; P=0.004), whereas there was a loss of between center difference using the distance formula (F=1.4; P=0.24). PWV odds ratios for cardiovascular mortality remained the same using both the external distance measurement (1.14; 95% confidence interval, 1.06-1.24; P=0.001) and the distance formula (1.17; 95% confidence interval, 1.08-1.28; P<0.001). A population-derived automatic distance calculation for PWV obtained from routinely collected clinical information is accurate and removes intercenter measurement variability without impacting the diagnostic utility of carotid-femoral PWV.


Subject(s)
Blood Flow Velocity/physiology , Blood Pressure/physiology , Magnetic Resonance Angiography/methods , Pulse Wave Analysis/methods , Vascular Stiffness , Adult , Age Factors , Aged , Analysis of Variance , Blood Pressure Determination/methods , Carotid Arteries/diagnostic imaging , Carotid Arteries/physiology , Cohort Studies , Female , Femoral Artery/diagnostic imaging , Femoral Artery/physiology , Humans , Logistic Models , Male , Middle Aged , Prospective Studies , Risk Assessment , Sex Factors , Whole Body Imaging
2.
BMC Cardiovasc Disord ; 17(1): 118, 2017 05 10.
Article in English | MEDLINE | ID: mdl-28486936

ABSTRACT

BACKGROUND: Carotid-femoral pulse wave velocity (cf-PWV) and aortic PWV measured using MRI (MRI-PWV) show good correlation, but with a significant and consistent bias across studies. The aim of the current study was to evaluate whether the differences between cf.-PWV and MRI-PWV can be accounted for by inaccuracies of currently used distance measurements. METHODS: One hundred fourteen study participants were recruited into one of 4 groups: Type 2 diabetes melltus (T2DM) with cardiovascular disease (CVD) (n = 23), T2DM without CVD (n = 41), CVD without T2DM (n = 25) and a control group (n = 25). All participants underwent cf.-PWV, cardiac MRI and whole body MR angiography(WB-MRA). 90 study participants also underwent aortic PWV using MRI. cf.-PWVEXT was performed using a SphygmoCor device (Atcor Medical, West Ryde, Australia). The true intra-arterial pathlength was measured using the WB-MRA and then used to recalculate the cf.-PWVEXT to give a cf.-PWVMRA. RESULTS: Distance measurements were significantly lower on WB-MRA than on external tape measure (mean diff = -85.4 ± 54.0 mm,p < 0.001). MRI-PWV was significantly lower than cf.-PWVEXT (MRI-PWV = 8.1 ± 2.9 vs. cf.-PWVEXT = 10.9 ± 2.7 ms-1,p < 0.001). When cf.-PWV was recalculated using the inter-arterial distance from WB-MRA, this difference was significantly reduced but not lost (MRI-PWV = 8.1 ± 2.9 ms-1 vs. cf.-PWVMRA 9.1 ± 2.1 ms-1, mean diff = -0.96 ± 2.52 ms-1,p = 0.001). Recalculation of the PWV increased correlation with age and pulse pressure. CONCLUSION: Differences in cf.-PWV and MRI PWV can be predominantly but not entirely explained by inaccuracies introduced by the use of simple surface measurements to represent the convoluted arterial path between the carotid and femoral arteries.


Subject(s)
Aorta/diagnostic imaging , Cardiovascular Diseases/diagnostic imaging , Carotid Arteries/diagnostic imaging , Diabetes Mellitus, Type 2/complications , Diabetic Angiopathies/diagnostic imaging , Femoral Artery/diagnostic imaging , Magnetic Resonance Angiography , Manometry , Pulse Wave Analysis/methods , Vascular Stiffness , Aged , Aorta/physiopathology , Cardiovascular Diseases/physiopathology , Carotid Arteries/physiopathology , Diabetes Mellitus, Type 2/diagnosis , Diabetic Angiopathies/etiology , Diabetic Angiopathies/physiopathology , Female , Femoral Artery/physiopathology , Humans , Male , Middle Aged , Predictive Value of Tests , Regional Blood Flow , Reproducibility of Results , Whole Body Imaging