Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
IEEE Open J Eng Med Biol ; 5: 99-106, 2024.
Article in English | MEDLINE | ID: mdl-38445240

ABSTRACT

Hyperthermia treatment consists of elevating the temperature of the tumor to increase the effectiveness of radiotherapy and chemotherapy. Hyperthermia treatment planning (HTP) is an important tool to optimize treatment quality using pre-treatment temperature predictions. The accuracy of these predictions depends on modeling uncertainties such as tissue properties and positioning. In this study, we evaluated if HTP accuracy improves when the patient is imaged inside the applicator at the start of treatment. Because perfusion is a major uncertainty source, the importance of accurate treatment position and anatomy was evaluated using different perfusion values. Volunteers were scanned using MR imaging without ("planning setup") and with the MR-compatible hyperthermia device ("treatment setup"). Temperature-based quality indicators were used to assess the differences between the standard, apparent and the optimized hyperthermia dose. We conclude that pre-treatment imaging can improve HTP predictions accuracy but also, that tissue perfusion modelling is crucial if temperature-based optimization is applied.

2.
Int J Hyperthermia ; 39(1): 1213-1221, 2022.
Article in English | MEDLINE | ID: mdl-36104074

ABSTRACT

OBJECTIVE: The addition of hyperthermia in the treatment of intact breast cancer with the aim to improve local response is currently in a research phase. First, optimal hyperthermia devices need to be developed, for which a diverse, anatomically and pathologically accurate set of patient models is necessary. METHODS: To investigate the effects of inter-subject variations on hyperthermia treatment plans, we generated a repository of 22 anatomically and pathologically diverse patient models based on MR images of breast cancer patients. Hyperthermia treatment plans were generated for the 22 models using a generic theoretical phased array hyperthermia applicator. RESULTS: Good temperature coverage was achieved in the vast majority of the models, with median values for T10 = 43.5°C (41.9-43.8°C), T50 = 42.5°C (41.3-43.3°C), and T90 = 41.3°C (39.8-42.6°C) under the condition that the maximum temperature increase in the patient is limited to 44°C. CONCLUSIONS: For future development of hyperthermia devices and treatment methods, a repository with a sufficiently large number of representative patient models, such as the one provided in this study, should be used to ensure applicability to a wide variety of patients. This repository is therefore made publicly available.


Subject(s)
Breast Neoplasms , Hyperthermia, Induced , Breast , Breast Neoplasms/therapy , Female , Humans , Hyperthermia, Induced/methods
3.
Phys Med ; 101: 87-94, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35987024

ABSTRACT

PURPOSE: Hyperthermia is a cancer treatment in which the target region is heated to temperatures of 40-44 °C usually applying external electromagnetic field sources. The behavior of the hyperthermia applicators (antennas) in clinical practice should be periodically checked with phantom experiments to verify the applicator's performance over time. The purpose of this study was to investigate the application of photogrammetry reconstructions of 3D applicator position in these quality control procedure measurements. METHODS: Photogrammetry reconstruction was applied at superficial hyperthermia scenario using the Lucite cone applicator (LCA) and phased-array heating in the head and neck region using the HYPERcollar3D. Wire-frame models of the entire measurement setups were created from multiple-view images and used for recreation of the setup inside 3D electromagnetic field simulation software. We evaluated applicator relation (Ra) between measured and simulated absolute specific absorption rate (SAR) for manually created and photogrammetry reconstructed simulation setups. RESULTS: We found a displacement of 7.9 mm for the LCA and 8.2 mm for the HYPERcollar3D setups when comparing manually created and photogrammetry reconstructed applicator models placements. Ra improved from 1.24 to 1.18 for the LCA and from 1.17 to 1.07 for the HYPERcollar3D when using photogrammetry reconstructed simulation setups. CONCLUSION: Photogrammetry reconstruction technique holds promise to improve measurement setup reconstruction and agreement between measured and simulated absolute SAR.


Subject(s)
Hyperthermia, Induced , Phantoms, Imaging , Photogrammetry , Polymethyl Methacrylate , Quality Control
4.
Cancers (Basel) ; 13(23)2021 Dec 06.
Article in English | MEDLINE | ID: mdl-34885258

ABSTRACT

(1) Background: Head and neck cancer (HNC) patients with recurrent or second primary (SP) tumors in previously irradiated areas represent a clinical challenge. Definitive or postoperative reirradiation with or without sensitizing therapy, like chemotherapy, should be considered. As an alternative to chemotherapy, hyperthermia has shown to be a potent sensitizer of radiotherapy in clinical studies in the primary treatment of HNC. At our institution, we developed the Hypercollar3D, as the successor to the Hypercollar, to enable improved application of hyperthermia for deeply located HNC. In this study, we report on the feasibility and clinical outcome of patients treated with the Hypercollar3D as an adjuvant to reirradiation in recurrent or SP HNC patients; (2) Methods: We retrospectively analyzed all patients with a recurrent or SP HNC treated with reirradiation combined with hyperthermia using the Hypercollar3D between 2014 and 2018. Data on patients, tumors, and treatments were collected. Follow-up data on disease specific outcomes as well as acute and late toxicity were collected. Data were analyzed using Kaplan Meier analyses; (3) Results: Twenty-two patients with recurrent or SP HNC were included. The average mean estimated applied cfSAR to the tumor volume for the last 17 patients was 80.5 W/kg. Therefore, the novel Hypercollar3D deposits 55% more energy at the target than our previous Hypercollar applicator. In patients treated with definitive thermoradiotherapy a complete response rate of 81.8% (9/11) was observed at 12 weeks following radiotherapy. Two-year local control (LC) and overall survival (OS) were 36.4% (95% CI 17.4-55.7%) and 54.6% (95% CI 32.1-72.4%), respectively. Patients with an interval longer than 24 months from their previous radiotherapy course had an LC of 66.7% (95% CI 37.5-84.6%), whereas patients with a time interval shorter than 24 months had an LC of 14.3% (95% CI 0.7-46.5%) at 18 months (p = 0.01). Cumulative grade 3 or higher toxicity was 39.2% (95% CI 16.0-61.9%); (4) Conclusions: Reirradiation combined with deep hyperthermia in HNC patients using the novel Hypercollar3D is feasible and deposits an average cfSAR of 80.5 W/kg in the tumor volume. The treatment results in high complete response rates at 12 weeks post-treatment. Local control and local toxicity rates were comparable to those reported for recurrent or SP HNC. To further optimize the hyperthermia treatment in the future, temperature feedback is warranted to apply heat at the maximum tolerable dose without toxicity. These data support further research in hyperthermia as an adjuvant to radiotherapy, both in the recurrent as well as in the primary treatment of HNC patients.

5.
Cancers (Basel) ; 13(22)2021 Nov 10.
Article in English | MEDLINE | ID: mdl-34830773

ABSTRACT

Clinical effectiveness of hyperthermia treatments, in which tumor tissue is artificially heated to 40-44 °C for 60-90 min, can be hampered by a lack of accurate temperature monitoring. The need for noninvasive temperature monitoring in the head and neck region (H&N) and the potential of MR thermometry prompt us to design an MR compatible hyperthermia applicator: the MRcollar. In this work, we validate the design, numerical model, and MR performance of the MRcollar. The MRcollar antennas have low reflection coefficients (<-15 dB) and the intended low interaction between the individual antenna modules (<-32 dB). A 10 °C increase in 3 min was reached in a muscle-equivalent phantom, such that the specifications from the European Society for Hyperthermic Oncology were easily reached. The MRcollar had a minimal effect on MR image quality and a five-fold improvement in SNR was achieved using the integrated coils of the MRcollar, compared to the body coil. The feasibility of using the MRcollar in an MR environment was shown by a synchronous heating experiment. The match between the predicted SAR and measured SAR using MR thermometry satisfied the gamma criteria [distance-to-agreement = 5 mm, dose-difference = 7%]. All experiments combined show that the MRcollar delivers on the needs for MR-hyperthermia in the H&N and is ready for in vivo investigation.

6.
Int J Hyperthermia ; 38(1): 1425-1442, 2021.
Article in English | MEDLINE | ID: mdl-34581246

ABSTRACT

BACKGROUND: The success of cancer hyperthermia (HT) treatments is strongly dependent on the temperatures achieved in the tumor and healthy tissues as it correlates with treatment efficacy and safety, respectively. Hyperthermia treatment planning (HTP) simulations have become pivotal for treatment optimization due to the possibility for pretreatment planning, optimization and decision making, as well as real-time treatment guidance. MATERIALS AND METHODS: The same computational methods deployed in HTP are also used for in silico studies. These are of great relevance for the development of new HT devices and treatment approaches. To aid this work, 3 D patient models have been recently developed and made available for the HT community. Unfortunately, there is no consensus regarding tissue properties, simulation settings, and benchmark applicators, which significantly influence the clinical relevance of computational outcomes. RESULTS AND DISCUSSION: Herein, we propose a comprehensive set of applicator benchmarks, efficacy and safety optimization algorithms, simulation settings and clinical parameters, to establish benchmarks for method comparison and code verification, to provide guidance, and in view of the 2021 ESHO Grand Challenge (Details on the ESHO grand challenge on HTP will be provided at https://www.esho.info/). CONCLUSION: We aim to establish guidelines to promote standardization within the hyperthermia community such that novel approaches can quickly prove their benefit as quickly as possible in clinically relevant simulation scenarios. This paper is primarily focused on radiofrequency and microwave hyperthermia but, since 3 D simulation studies on heating with ultrasound are now a reality, guidance as well as a benchmark for ultrasound-based hyperthermia are also included.


Subject(s)
Hyperthermia, Induced , Neoplasms , Benchmarking , Computer Simulation , Humans , Hyperthermia , Neoplasms/therapy
7.
Int J Hyperthermia ; 38(1): 382-392, 2021.
Article in English | MEDLINE | ID: mdl-33682594

ABSTRACT

PURPOSE: To develop a head and neck hyperthermia phased array system compatible with a 1.5 T magnetic resonance (MR) scanner for noninvasive thermometry. METHODS: We designed a dielectric-parabolic-reflector antenna (DiPRA) based on a printed reflector backed dipole antenna and studied its predicted and measured performance in a flat configuration (30 mm thick water bolus and muscle equivalent layer). Thereafter, we designed a phased array applicator model ('MRcollar') consisting of 12 DiPRA modules placed on a radius of 180 mm. Theoretical heating performance of the MRcollar model was benchmarked against the current clinical applicator (HYPERcollar3D) using specific (3D) head and neck models of 28 treated patients. Lastly, we assessed the influence of the DiPRA modules on MR scanning quality. RESULTS: The predicted and measured reflection coefficients (S11) of the DiPRA module are below -20 dB. The maximum specific absorption rate (SAR) in the area under the antenna was 47% higher than for the antenna without encasing. Compared to the HYPERcollar3D, the MRcollar design incorporates 31% less demineralized water (-2.5 L), improves the predicted TC25 (target volume enclosed by 25% iso-SAR contour) by 4.1% and TC50 by 8.5%, while the target-to-hotspot quotient (THQ) is minimally affected (-1.6%). MR experiments showed that the DiPRA modules do not affect MR transmit/receive performance. CONCLUSION: Our results suggest that head and neck hyperthermia delivery quality with the MRcollar can be maintained, while facilitating simultaneous noninvasive MR thermometry for treatment monitoring and control.


Subject(s)
Heating , Hyperthermia, Induced , Head/diagnostic imaging , Humans , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Neck/diagnostic imaging
8.
IEEE Trans Biomed Eng ; 68(2): 712-717, 2021 02.
Article in English | MEDLINE | ID: mdl-32746075

ABSTRACT

Temperature monitoring plays a central role in improving clinical effectiveness of adjuvant hyperthermia. The potential of magnetic resonance thermometry for treatment monitoring purposes led to several MR-guided hyperthermia approaches. However, the proposed solutions were sub-optimal due to technological and intrinsic limitations. These hamper achieving target conformal heating possibilities (applicator limitations) and accurate thermometry (inadequate signal-to-noise-ratio (SNR)). In this work, we studied proof of principle of a dual-function hyperthermia approach based on a coil array (64 MHz, 1.5 T) that is integrated in-between a phased array for heating (434 MHz) for maximum signal receive in order to improve thermometry accuracy. Hereto, we designed and fabricated a superficial hyperthermia mimicking planar array setup to study the most challenging interactions of generic phased-array setups in order to validate the integrated approach. Experiments demonstrated that the setup complies with the superficial hyperthermia guidelines for heating and is able to improve SNR at 2-4 cm depth by 17%, as compared to imaging using the body coil. Hence, the results showed the feasibility of our dual-function MR-guided hyperthermia approach as basis for the development of application specific setups.


Subject(s)
Hyperthermia, Induced , Thermometry , Humans , Hyperthermia , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy
9.
Sensors (Basel) ; 20(16)2020 Aug 13.
Article in English | MEDLINE | ID: mdl-32823788

ABSTRACT

Tissue mimicking phantoms are frequently used in hyperthermia applications for device and protocol optimization. Unfortunately, a commonly experienced limitation is that their precise thermal properties are not available. Therefore, in this study, the thermal properties of three currently used QA phantoms for deep hyperthermia are measured with an "off-shelf" commercial thermal property analyzer. We have measured averaged values of thermal conductivity (k = 0.59 ± 0.07 Wm-1K-1), volumetric heat capacity (C = 3.85 ± 0.45 MJm-3K-1) and thermal diffusivity (D = 0.16 ± 0.02 mm2s-1). These values are comparable with reported values of internal organs, such as liver, kidney and muscle. In addition, a sensitivity study of the performance of the commercial sensor is conducted. To ensure correct thermal measurements, the sample under test should entirely cover the length of the sensor, and a minimum of 4 mm of material parallel to the sensor in all directions should be guaranteed.


Subject(s)
Hyperthermia, Induced , Monitoring, Physiologic , Hot Temperature , Humans , Hyperthermia , Phantoms, Imaging , Thermal Conductivity
10.
Int J Hyperthermia ; 37(1): 608-616, 2020.
Article in English | MEDLINE | ID: mdl-32515240

ABSTRACT

Purpose: Thermal dose-effect relations have demonstrated that clinical effectiveness of hyperthermia would benefit from more controlled heating of the tumor. Hyperthermia treatment planning (HTP) is a potent tool to study strategies enabling target conformal heating, but its accuracy is affected by patient modeling approximations. Homogeneous phantoms models are being used that do not match the body shape of patients in treatment position and often have unrealistic target volumes. As a consequence, simulation accuracy is affected, and performance comparisons are difficult. The aim of this study is to provide the first step toward standardization of HTP simulation studies in terms of patient modeling by introducing the Erasmus Virtual Patient Repository (EVPR): a virtual patient model database.Methods: Four patients with a tumor in the head and neck or the pelvis region were selected, and corresponding models were created using a clinical segmentation procedure. Using the Erasmus University Medical Center standard procedure, HTP was applied to these models and compared to HTP for commonly used surrogate models.Results: Although this study was aimed at presenting the EVPR database, our study illustrates that there is a non-negligible difference in the predicted SAR patterns between patient models and homogeneous phantom-based surrogate models. We further demonstrate the difference between actual and simplified target volumes being used today.Conclusion: Our study describes the EVPR for the research community as a first step toward standardization of hyperthermia simulation studies.


Subject(s)
Hyperthermia, Induced , Hyperthermia , Computer Simulation , Head , Humans , Reference Standards
11.
Sensors (Basel) ; 20(10)2020 May 22.
Article in English | MEDLINE | ID: mdl-32456027

ABSTRACT

The potential of MR thermometry (MRT) fostered the development of MRI compatible radiofrequency (RF) hyperthermia devices. Such device integration creates major technological challenges and a crucial point for image quality is the water bolus (WB). The WB is located between the patient body and external sources to both couple electromagnetic energy and to cool the patient skin. However, the WB causes MRT errors and unnecessarily large field of view. In this work, we studied making the WB MRI transparent by an optimal concentration of compounds capable of modifying T 2 * relaxation without an impact on the efficiency of RF heating. Three different T 2 * reducing compounds were investigated, namely CuSO 4 , MnCl 2 , and Fe 3 O 4 . First, electromagnetic properties and T 2 * relaxation rates at 1.5 T were measured. Next, through multi-physics simulations, the predicted effect on the RF-power deposition pattern was evaluated and MRT precision was experimentally assessed. Our results identified 5 mM Fe 3 O 4 solution as optimal since it does not alter the RF-power level needed and improved MRT precision from 0.39 ∘ C to 0.09 ∘ C. MnCl 2 showed a similar MRT improvement, but caused unacceptable RF-power losses. We conclude that adding Fe 3 O 4 has significant potential to improve RF hyperthermia treatment monitoring under MR guidance.


Subject(s)
Hyperthermia, Induced/methods , Magnetic Resonance Imaging , Radio Waves , Thermometry , Humans , Phantoms, Imaging , Water
12.
Int J Hyperthermia ; 37(1): 15-27, 2020.
Article in English | MEDLINE | ID: mdl-31918599

ABSTRACT

Clinical trials have demonstrated the therapeutic benefits of adding radiofrequency (RF) hyperthermia (HT) as an adjuvant to radio- and chemotherapy. However, maximum utilization of these benefits is hampered by the current inability to maintain the temperature within the desired range. RF HT treatment quality is usually monitored by invasive temperature sensors, which provide limited data sampling and are prone to infection risks. Magnetic resonance (MR) temperature imaging has been developed to overcome these hurdles by allowing noninvasive 3D temperature monitoring in the target and normal tissues. To exploit this feature, several approaches for inserting the RF heating devices into the MR scanner have been proposed over the years. In this review, we summarize the status quo in MR-guided RF HT devices and analyze trends in these hybrid hardware configurations. In addition, we discuss the various approaches, extract best practices and identify gaps regarding the experimental validation procedures for MR - RF HT, aimed at converging to a common standard in this process.


Subject(s)
Hyperthermia, Induced/methods , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy/methods , Radiofrequency Therapy/methods , Humans
13.
Int J Hyperthermia ; 36(1): 801-811, 2019.
Article in English | MEDLINE | ID: mdl-31450989

ABSTRACT

Purpose: To investigate the effect of patient specific vessel cooling on head and neck hyperthermia treatment planning (HTP). Methods and materials: Twelve patients undergoing radiotherapy were scanned using computed tomography (CT), magnetic resonance imaging (MRI) and contrast enhanced MR angiography (CEMRA). 3D patient models were constructed using the CT and MRI data. The arterial vessel tree was constructed from the MRA images using the 'graph-cut' method, combining information from Frangi vesselness filtering and region growing, and the results were validated against manually placed markers in/outside the vessels. Patient specific HTP was performed and the change in thermal distribution prediction caused by arterial cooling was evaluated by adding discrete vasculature (DIVA) modeling to the Pennes bioheat equation (PBHE). Results: Inclusion of arterial cooling showed a relevant impact, i.e., DIVA modeling predicts a decreased treatment quality by on average 0.19 °C (T90), 0.32 °C (T50) and 0.35 °C (T20) that is robust against variations in the inflow blood rate (|ΔT| < 0.01 °C). In three cases, where the major vessels transverse target volume, notable drops (|ΔT| > 0.5 °C) were observed. Conclusion: Addition of patient-specific DIVA into the thermal modeling can significantly change predicted treatment quality. In cases where clinically detectable vessels pass the heated region, we advise to perform DIVA modeling.


Subject(s)
Blood Vessels/diagnostic imaging , Head and Neck Neoplasms/blood supply , Hyperthermia, Induced , Patient-Specific Modeling , Blood Vessels/anatomy & histology , Feasibility Studies , Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/therapy , Humans , Magnetic Resonance Imaging , Temperature , Therapy, Computer-Assisted , Tomography, X-Ray Computed
14.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 614-7, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26736337

ABSTRACT

In this paper, recently proposed Induced Current Magnetic Resonance Current Density Imaging (ICMRCDI) is experimentally realized. The reconstructed current density images from the simulated measurements and from the physical measurements are in agreement. The proposed method is promising in reconstructing images of electrical conductivity as well as images of induced current density distribution within the body.


Subject(s)
Magnetic Resonance Imaging , Algorithms , Electric Conductivity , Electric Impedance , Magnetic Resonance Spectroscopy , Phantoms, Imaging , Tomography
SELECTION OF CITATIONS
SEARCH DETAIL
...