Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
J Glaucoma ; 33(1): 24-27, 2024 01 01.
Article in English | MEDLINE | ID: mdl-37671557

ABSTRACT

PRCIS: Drive-through intraocular pressure (IOP) measurement using iCare tonometry is a promising method of low-contact, high-throughput IOP monitoring. However, owing to its vulnerability to variable measurement technique and local air currents, the iCare may overestimate IOPs. PURPOSE: During the COVID-19 pandemic, a drive-through IOP measurement protocol using the iCare tonometer was established to facilitate low-contact monitoring of select glaucoma patients. As the iCare may be prone to error due to variable measurement technique and local air currents, we endeavored to assess the reliability of drive-through IOP measurements by comparing them with recent measurements taken in clinic settings. METHODS: Inclusion criteria were patients with drive-through IOP measurements performed from April 28 to October 11, 2020; exclusion criteria were pre-drive-through IOPs >21 mmHg. Drive-through IOP measurements were compared with the closest previous and/or subsequent in-clinic IOP measurements. Data were gathered using the Sight Outcomes Research Collaborative (SOURCE) data repository. RESULTS: The post-exclusion study group consisted of 314 patients receiving a total of 868 drive-through IOP measurements, all of whom had prior in-clinic measurements, and 56.8% of whom had subsequent in-clinic measurements. Drive-through IOPs were, on average, +2.4 mmHg (+14.5%; SD 4.9) higher than in-clinic IOPs. Further sub-analysis of the data showed a difference of +2.1 mmHg OD and +2.6 mmHg OS. Compared with the closest previous in-clinic visit, the difference was +2.4 mmHg OU (+2.1 mmHg OD, +2.7 mmHg OS); compared with the closest subsequent in-clinic visit, the difference was +2.3 mmHg OU (+2.1 mmHg OD, +2.5 mmHg OS). 68.6% of all drive-through IOPs were higher than corresponding in-clinic IOPs; 21.1% were lower. 25.9% of drive-through IOPs were higher by more than 5 mmHg, whereas 3.9% of drive-through IOPs were lower by more than 5 mmHg. DISCUSSION: As teleophthalmology becomes an ever more important tool in glaucoma patient care, drive-through or walk-through IOP monitoring methods are likely to play an increasing role. However, our data reveals potential inaccuracies in drive-through iCare IOP measurements which tended to overestimate IOP. It is advisable to confirm large changes in IOP with in-clinic measurement before making management decisions. CONCLUSION: With better optimization of accuracy and reliability of measurements, drive-through tonometry is a promising, high-throughput, low-contact method of measuring IOP.


Subject(s)
Glaucoma , Ocular Hypertension , Ophthalmology , Telemedicine , Humans , Intraocular Pressure , Ocular Hypertension/diagnosis , Reproducibility of Results , Pandemics , Glaucoma/diagnosis , Tonometry, Ocular/methods , Manometry
2.
Am J Ophthalmol Case Rep ; 32: 101910, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37663999

ABSTRACT

Purpose: To report a highly unusual and fulminant case of infectious fungal panophthalmitis that initially presented as angle closure in the setting of posterior scleritis, culminating in the loss of the affected eye. Observations: A 57-year-old woman with a history of poorly controlled diabetes mellitus and autoimmune disease presented with a unilateral flat anterior chamber, highly elevated intraocular pressure (50-65 mmHg) and severe chemosis of the right eye. Initial VA was NLP in the affected eye. An ultrasound B-scan revealed a very pronounced T-sign and severely thickened posterior sclera and choroid indicative of posterior scleritis. Bloodwork showed elevation of WBC count to 18 K/µL and broad spectrum antibiotics were initiated. However, a comprehensive infectious workup including fungal cultures were persistently negative. After three days of IV NSAIDs and antibiotics, WBC count normalized and pain had mildly improved. After consultation with a multidisciplinary team that included the Glaucoma, Retina/Uveitis, Infectious Disease, Rheumatology and Internal Medicine services, high dose IV methylprednisolone was started. Despite the initial improvement, corneoscleral decompensation and paralimbal perforation of the globe occurred. The eye was enucleated, and pathologic examination revealed a dense focus of budding yeast in the vitreous cavity. Conclusions and importance: Scleritis is a rare entity, with posterior scleritis, infectious scleritis, and fungal scleritis representing increasingly rare subtypes. However, fungal scleritis may be underdiagnosed due to a number of factors including culture negativity, a lack of clinical suspicion, as well as the disease's propensity to masquerade as other pathologies such as angle closure or malignant glaucoma. Fungal scleritis should be considered in cases that present with possible infectious etiology, worsen with systemic corticosteroid treatment, or worsen despite broad-spectrum antibiotic coverage. When treating patients with underlying risk factors such as uncontrolled diabetes mellitus, recent antibiotic use, use of total parenteral nutrition, or immunosuppression, a higher level of suspicion for fungal etiology is also appropriate. In the outpatient setting, fungal eye infections do not always present with critical systemic illness or culture positivity. If there is suspicion for fungal involvement, early aqueous or vitreous tap may improve diagnostic yield.

5.
JAMA Ophthalmol ; 137(5): 552-556, 2019 05 01.
Article in English | MEDLINE | ID: mdl-30946427

ABSTRACT

Importance: Clinical trial registries are intended to increase clinical research transparency by nonselectively identifying and documenting clinical trial designs and outcomes. Inconsistencies in reported data undermine the utility of such registries and have previously been noted in general medical literature. Objective: To assess whether inconsistencies in reported data exist between ophthalmic literature and clinical trial registries. Design, Setting, and Participants: In this retrospective, cross-sectional study, interventional clinical trials published from January 1, 2014, to December 31, 2014, in the American Journal of Ophthalmology, JAMA Ophthalmology, and Ophthalmology were reviewed. Observational, retrospective, uncontrolled, and post hoc reports were excluded, yielding a sample size of 106 articles. Data collection was performed from January through September 2016. Data review and adjudication continued through January 2017. Main Outcomes and Measures: If possible, articles were matched to registry entries listed in the ClinicalTrials.gov database or in 1 of 16 international registries indexed by the World Health Organization International Clinical Trials Registry Platform version 3.2 search engine. Each article-registry pair was assessed for inconsistencies in design, results, and funding (each of which was further divided into subcategories) by 2 reviewers and adjudicated by a third. Results: Of 106 trials that met the study criteria, matching registry entries were found for 68 (64.2%), whereas no matching registry entries were found for 38 (35.8%). Inconsistencies were identified in study design, study results, and funding sources, including specific interventions in 8 (11.8%), primary outcome measure (POM) designs in 32 (47.1%), and POM results in 48 (70.6%). In addition, numerous data pieces were unreported, including analysis methods in 52 (76.5%) and POM results in 38 (55.9%). Conclusions and Relevance: Clinical trial registries were underused in this sample of ophthalmology clinical trials. For studies with registry data, inconsistency rates between published and registered data were similar to those previously reported for general medical literature. In most cases, inconsistencies involved missing data, but explicit discrepancies in methods and/or data were also found. Transparency and credibility of published trials may be improved by closer attention to their registration and reporting.


Subject(s)
Clinical Trials as Topic , Ophthalmology , Registries/standards , Cross-Sectional Studies , Databases, Factual/standards , Humans , Peer Review , Publications , Research Design , Retrospective Studies
6.
Am J Ophthalmol Case Rep ; 8: 74-77, 2017 Dec.
Article in English | MEDLINE | ID: mdl-29260123

ABSTRACT

PURPOSE: To present ophthalmic imaging findings in the case of a 40-year-old male with sustained visual loss after a single episode of acute central serous retinopathy (CSR). OBSERVATIONS: A male subject presented with visual acuity decline to 20/50 OS and was diagnosed with acute CSR. The initial pigment epithelial detachment and subretinal fluid resolved within 6 weeks, but visual acuity remained impaired. Using directional optical coherence tomography (D-OCT) and confocal and split-detector adaptive optics scanning light ophthalmoscopy (AOSLO), we imaged pathologic alterations in the photoreceptor mosaic of the affected eye. A foveal region of intermittent missing cones, a temporal parafoveal region of confluent missing cones, and a nasal parafoveal region of misdirected cones were observed. CONCLUSIONS AND IMPORTANCE: Pathologic alterations in photoreceptor microanatomy underlie residual visual acuity deficits in this case of acute CSR. Observations of missing cones correlated well across all imaging modalities in the fovea and the temporal parafoveal region of missing cones. However, in the nasal parafovea where cones were present but misdirected, D-OCT and AOSLO may be able to identify and image photoreceptors with greater fidelity as compared to non-directional SDOCT (spectral domain OCT). D-OCT may thus have a clinical role in rapidly assessing photoreceptor mosaic integrity in pathology.

7.
PLoS One ; 11(12): e0167526, 2016.
Article in English | MEDLINE | ID: mdl-27936069

ABSTRACT

PURPOSE: Choroideremia is a progressive X-linked recessive dystrophy, characterized by degeneration of the retinal pigment epithelium (RPE), choroid, choriocapillaris, and photoreceptors. We examined photoreceptor structure in a series of subjects with choroideremia with particular attention to areas bordering atrophic lesions. METHODS: Twelve males with clinically-diagnosed choroideremia and confirmed hemizygous mutations in the CHM gene were examined. High-resolution images of the retina were obtained using spectral domain optical coherence tomography (SD-OCT) and both confocal and non-confocal split-detector adaptive optics scanning light ophthalmoscope (AOSLO) techniques. RESULTS: Eleven CHM gene mutations (3 novel) were identified; three subjects had the same mutation and one subject had two mutations. SD-OCT findings included interdigitation zone (IZ) attenuation or loss in 10/12 subjects, often in areas with intact ellipsoid zones; RPE thinning in all subjects; interlaminar bridges in the imaged areas of 10/12 subjects; and outer retinal tubulations (ORTs) in 10/12 subjects. Only split-detector AOSLO could reliably resolve cones near lesion borders, and such cones were abnormally heterogeneous in morphology, diameter and density. On split-detector imaging, the cone mosaic terminated sharply at lesion borders in 5/5 cases examined. Split-detector imaging detected remnant cone inner segments within ORTs, which were generally contiguous with a central patch of preserved retina. CONCLUSIONS: Early IZ dropout and RPE thinning on SD-OCT are consistent with previously published results. Evidence of remnant cone inner segments within ORTs and the continuity of the ORTs with preserved retina suggests that these may represent an intermediate state of retinal degeneration prior to complete atrophy. Taken together, these results supports a model of choroideremia in which the RPE degenerates before photoreceptors.


Subject(s)
Choroideremia/pathology , Multimodal Imaging/methods , Retina/diagnostic imaging , Retinal Degeneration/diagnostic imaging , Adaptor Proteins, Signal Transducing/genetics , Adult , Aged , Choroideremia/genetics , Humans , Male , Middle Aged , Mutation , Ophthalmoscopy/methods , Reproducibility of Results , Retina/pathology , Retinal Cone Photoreceptor Cells/pathology , Retinal Photoreceptor Cell Inner Segment/pathology , Sensitivity and Specificity , Tomography, Optical Coherence/methods , Young Adult
8.
Invest Ophthalmol Vis Sci ; 57(6): 2428-42, 2016 05 01.
Article in English | MEDLINE | ID: mdl-27145477

ABSTRACT

PURPOSE: The purpose of this study was to examine cone photoreceptor structure in retinitis pigmentosa (RP) and Usher syndrome using confocal and nonconfocal split-detector adaptive optics scanning light ophthalmoscopy (AOSLO). METHODS: Nineteen subjects (11 RP, 8 Usher syndrome) underwent ophthalmic and genetic testing, spectral-domain optical coherence tomography (SD-OCT), and AOSLO imaging. Split-detector images obtained in 11 subjects (7 RP, 4 Usher syndrome) were used to assess remnant cone structure in areas of altered cone reflectivity on confocal AOSLO. RESULTS: Despite normal interdigitation zone and ellipsoid zone appearance on OCT, foveal and parafoveal cone densities derived from confocal AOSLO images were significantly lower in Usher syndrome compared with RP. This was due in large part to an increased prevalence of non-waveguiding cones in the Usher syndrome retina. Although significantly correlated to best-corrected visual acuity and foveal sensitivity, cone density can decrease by nearly 38% before visual acuity becomes abnormal. Aberrantly waveguiding cones were noted within the transition zone of all eyes and corresponded to intact inner segment structures. These remnant cones decreased in density and increased in diameter across the transition zone and disappeared with external limiting membrane collapse. CONCLUSIONS: Foveal cone density can be decreased in RP and Usher syndrome before visible changes on OCT or a decline in visual function. Thus, AOSLO imaging may allow more sensitive monitoring of disease than current methods. However, confocal AOSLO is limited by dependence on cone waveguiding, whereas split-detector AOSLO offers unambiguous and quantifiable visualization of remnant cone inner segment structure. Confocal and split-detector thus offer complementary insights into retinal pathology.


Subject(s)
Fovea Centralis/pathology , Ophthalmoscopy/methods , Photoreceptor Cells, Vertebrate/pathology , Retinitis Pigmentosa/diagnosis , Tomography, Optical Coherence/methods , Usher Syndromes/diagnosis , Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Severity of Illness Index , Visual Acuity , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...