Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 25(25): 32074-32079, 2017 Dec 11.
Article in English | MEDLINE | ID: mdl-29245872

ABSTRACT

An all-optical framing camera has been developed which measures the spatial profile of photons flux by utilizing a laser beam to probe the refractive index change in an indium phosphide semiconductor. This framing camera acquires two frames with the time resolution of about 1.5 ns and the inter frame separation time of about 13 ns by angularly multiplexing the probe beam on to the semiconductor. The spatial resolution of this camera has been estimated to be about 140 µm and the spectral response of this camera has also been theoretically investigated in 5 eV-100 KeV range. This camera has been applied in investigating the imploding dynamics of the molybdenum planar wire array Z-pinch on the 1-MA "QiangGuang-1" facility. This framing camera can provide an alternative scheme for high energy density physics experiments.

2.
Rev Sci Instrum ; 87(9): 093508, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27782584

ABSTRACT

A kind of fast shutter for protecting the diagnosis devices in Z pinch experiments is introduced in this paper. The shutter is composed of a pulling rod, a magnetic core, and a solenoid. Different from the traditional coils which were used at the voltage of 220 V, the solenoid we used must endure the high voltage of 5-10 kV and the deformation which maybe caused by the 5-10 T intense magnetic field. A creative configuration for the solenoid is developed including the winding guide, insulating sleeve, and stainless-steel sleeve. The experimental results show that the configuration of the solenoid is effective. The velocity of the valve is nearly 19 m/s and the time jitter of the shutdown is within 75 µs.

3.
Rev Sci Instrum ; 86(10): 106109, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26521006

ABSTRACT

In this article, we describe a rectangular pulse generator, consisting of a polymer-film switch, a tri-plate transmission line, and parallel post-shaped ceramic resistor load, for 50-kV voltage, 0.8-ns rise time, and 10-ns width. The switch and resistors are arranged in atmospheric air and the transmission line can work in atmospheric air or in transformer oil to change the pulse width from 6.7 ns to 10 ns. The fast switching and low-inductance characteristics of the polymer-film switch ensure the fast rising wavefront of <1 ns. This generator can be applied in the calibration of nanosecond voltage dividers and used for electromagnetic pulse tests as a fast-rising current injection source.

4.
Rev Sci Instrum ; 84(3): 033504, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23556818

ABSTRACT

A capacitive divider was arranged on Qiangguang pulsed power generator during a series of wire-array Z-pinch experiments. This divider was designed to measure the voltage acted on the gap of the cathode and anode boards. The probe has a compact construction and is conveniently assembled on the facility. It is also a cheap voltage probe and easy to build by research groups. The probe can monitor a 1 MV high voltage with a 100 ns rise time. The calibration results showed that the probe had an attenuation ratio of 3.3 × 10(5) and a response time less than 5 ns. The uncertainty was estimated to be 3%.