Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 17(3)2017 Mar 07.
Article in English | MEDLINE | ID: mdl-28272330

ABSTRACT

A novel micro-electro-mechanical systems (MEMS) inertial microswitch with a flexible contact-enhanced structure to extend the contact duration has been proposed in the present work. In order to investigate the stiffness k of the stationary electrodes, the stationary electrodes with different shapes, thickness h, width b, and length l were designed, analyzed, and simulated using ANSYS software. Both the analytical and the simulated results indicate that the stiffness k increases with thickness h and width b, while decreasing with an increase of length l, and it is related to the shape. The inertial micro-switches with different kinds of stationary electrodes were simulated using ANSYS software and fabricated using surface micromachining technology. The dynamic simulation indicates that the contact time will decrease with the increase of thickness h and width b, but increase with the length l, and it is related to the shape. As a result, the contact time decreases with the stiffness k of the stationary electrode. Furthermore, the simulated results reveal that the stiffness k changes more rapidly with h and l compared to b. However, overlarge dimension of the whole microswitch is contradicted with small footprint area expectation in the structure design. Therefore, it is unreasonable to extend the contact duration by increasing the length l excessively. Thus, the best and most convenient way to prolong the contact time is to reduce the thickness h of the stationary electrode while keeping the plane geometric structure of the inertial micro-switch unchanged. Finally, the fabricated micro-switches with different shapes of stationary electrodes have been evaluated by a standard dropping hammer system. The test maximum contact time under 288 g acceleration can reach 125 µs. It is shown that the test results are in accordance with the simulated results. The conclusions obtained in this work can provide guidance for the future design and fabrication of inertial microswitches.

2.
J Digit Imaging ; 25(6): 729-37, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22535192

ABSTRACT

The development cycle of an image-guided surgery navigation system is too long to meet current clinical needs. This paper presents an integrated system developed by the integration of two open-source software (IGSTK and MITK) to shorten the development cycle of the image-guided surgery navigation system and save human resources simultaneously. An image-guided surgery navigation system was established by connecting the two aforementioned open-source software libraries. It used the Medical Imaging Interaction Toolkit (MITK) as a framework providing image processing tools for the image-guided surgery navigation system of medical imaging software with a high degree of interaction and used the Image-Guided Surgery Toolkit (IGSTK) as a library that provided the basic components of the system for location, tracking, and registration. The electromagnetic tracking device was used to measure the real-time position of surgical tools and fiducials attached to the patient's anatomy. IGSTK was integrated into MITK; at the same time, the compatibility and the stability of this system were emphasized. Experiments showed that an integrated system of the image-guided surgery navigation system could be developed in 2 months. The integration of IGSTK into MITK is feasible. Several techniques for 3D reconstruction, geometric analysis, mesh generation, and surface data analysis for medical image analysis of MITK can connect with the techniques for location, tracking, and registration of IGSTK. This integration of advanced modalities can decrease software development time and emphasize the precision, safety, and robustness of the image-guided surgery navigation system.


Subject(s)
Diagnostic Imaging , Image Processing, Computer-Assisted/methods , Software , Surgery, Computer-Assisted , Systems Integration , Calibration , Computer Systems , Data Display , Database Management Systems , Humans , Information Storage and Retrieval , Phantoms, Imaging , Software Design , Software Validation , User-Computer Interface
SELECTION OF CITATIONS
SEARCH DETAIL
...