2.
J Synchrotron Radiat ; 29(Pt 2): 581-590, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-35254323

ABSTRACT

ID23-2 is a fixed-energy (14.2 keV) microfocus beamline at the European Synchrotron Radiation Facility (ESRF) dedicated to macromolecular crystallography. The optics and sample environment have recently been redesigned and rebuilt to take full advantage of the upgrade of the ESRF to the fourth generation Extremely Brilliant Source (ESRF-EBS). The upgraded beamline now makes use of two sets of compound refractive lenses and multilayer mirrors to obtain a highly intense (>1013 photons s-1) focused microbeam (minimum size 1.5 µm × 3 µm full width at half-maximum). The sample environment now includes a FLEX-HCD sample changer/storage system, as well as a state-of-the-art MD3Up high-precision multi-axis diffractometer. Automatic data reduction and analysis are also provided for more advanced protocols such as synchrotron serial crystallographic experiments.


Subject(s)
Lenses , Synchrotrons , Crystallography, X-Ray , Data Collection , Macromolecular Substances/chemistry
3.
J Synchrotron Radiat ; 27(Pt 3): 844-851, 2020 May 01.
Article in English | MEDLINE | ID: mdl-32381789

ABSTRACT

ID30A-3 (or MASSIF-3) is a mini-focus (beam size 18 µm × 14 µm) highly intense (2.0 × 1013 photons s-1), fixed-energy (12.81 keV) beamline for macromolecular crystallography (MX) experiments at the European Synchrotron Radiation Facility (ESRF). MASSIF-3 is one of two fixed-energy beamlines sited on the first branch of the canted undulator setup on the ESRF ID30 port and is equipped with a MD2 micro-diffractometer, a Flex HCD sample changer, and an Eiger X 4M fast hybrid photon-counting detector. MASSIF-3 is recommended for collecting diffraction data from single small crystals (≤15 µm in one dimension) or for experiments using serial methods. The end-station has been in full user operation since December 2014, and here its current characteristics and capabilities are described.

4.
J Synchrotron Radiat ; 25(Pt 4): 1249-1260, 2018 Jul 01.
Article in English | MEDLINE | ID: mdl-29979188

ABSTRACT

ID30B is an undulator-based high-intensity, energy-tuneable (6.0-20 keV) and variable-focus (20-200 µm in diameter) macromolecular crystallography (MX) beamline at the ESRF. It was the last of the ESRF Structural Biology Group's beamlines to be constructed and commissioned as part of the ESRF's Phase I Upgrade Program and has been in user operation since June 2015. Both a modified microdiffractometer (MD2S) incorporating an in situ plate screening capability and a new flexible sample changer (the FlexHCD) were specifically developed for ID30B. Here, the authors provide the current beamline characteristics and detail how different types of MX experiments can be performed on ID30B (http://www.esrf.eu/id30b).

5.
Acta Crystallogr D Struct Biol ; 72(Pt 8): 966-75, 2016 08.
Article in English | MEDLINE | ID: mdl-27487827

ABSTRACT

Automation of the mounting of cryocooled samples is now a feature of the majority of beamlines dedicated to macromolecular crystallography (MX). Robotic sample changers have been developed over many years, with the latest designs increasing capacity, reliability and speed. Here, the development of a new sample changer deployed at the ESRF beamline MASSIF-1 (ID30A-1), based on an industrial six-axis robot, is described. The device, named RoboDiff, includes a high-capacity dewar, acts as both a sample changer and a high-accuracy goniometer, and has been designed for completely unattended sample mounting and diffraction data collection. This aim has been achieved using a high level of diagnostics at all steps of the process from mounting and characterization to data collection. The RoboDiff has been in service on the fully automated endstation MASSIF-1 at the ESRF since September 2014 and, at the time of writing, has processed more than 20 000 samples completely automatically.


Subject(s)
Crystallography, X-Ray/instrumentation , Proteins/chemistry , Animals , Bacillus/chemistry , Bacterial Proteins/chemistry , Cattle , Crystallography, X-Ray/economics , Crystallography, X-Ray/methods , Equipment Design , Robotics , Software , Thermolysin/chemistry , Trypsin/chemistry
6.
J Synchrotron Radiat ; 22(6): 1540-7, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26524320

ABSTRACT

MASSIF-1 (ID30A-1) is an ESRF undulator beamline operating at a fixed wavelength of 0.969 Å (12.8 keV) that is dedicated to the completely automatic characterization of and data collection from crystals of biological macromolecules. The first of the ESRF Upgrade MASSIF beamlines to be commissioned, it has been open since September 2014, providing a unique automated data collection service to academic and industrial users. Here, the beamline characteristics and details of the new service are outlined.


Subject(s)
Crystallization/instrumentation , Crystallography, X-Ray/instrumentation , Information Storage and Retrieval/methods , Multiprotein Complexes/chemistry , Multiprotein Complexes/ultrastructure , Synchrotrons/instrumentation , Algorithms , Biopolymers/chemistry , Equipment Design , Equipment Failure Analysis , Robotics/instrumentation
7.
J Synchrotron Radiat ; 20(Pt 4): 660-4, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23765312

ABSTRACT

Small-angle X-ray scattering (SAXS) measurements of proteins in solution are becoming increasingly popular with biochemists and structural biologists owing to the presence of dedicated high-throughput beamlines at synchrotron sources. As part of the ESRF Upgrade program a dedicated instrument for performing SAXS from biological macromolecules in solution (BioSAXS) has been installed at the renovated BM29 location. The optics hutch has been equipped with new optical components of which the two principal elements are a fixed-exit double multilayer monochromator and a 1.1 m-long toroidal mirror. These new dedicated optics give improved beam characteristics (compared with the previous set-up on ID14-3) regarding the energy tunability, flux and focusing at the detector plane leading to reduced parasitic scattering and an extended s-range. User experiments on the beamline have been successfully carried out since June 2012. A description of the new BioSAXS beamline and the set-up characteristics are presented together with examples of obtained data.


Subject(s)
Proteins/chemistry , Scattering, Small Angle , Solutions
8.
J Synchrotron Radiat ; 19(Pt 3): 455-61, 2012 May.
Article in English | MEDLINE | ID: mdl-22514185

ABSTRACT

ID29 is an ESRF undulator beamline with a routinely accessible energy range of between 20.0 keV and 6.0 keV (λ = 0.62 Što 2.07 Å) dedicated to the use of anomalous dispersion techniques in macromolecular crystallography. Since the beamline was first commissioned in 2001, ID29 has, in order to provide an improved service to both its academic and proprietary users, been the subject of almost continuous upgrade and refurbishment. It is now also the home to the ESRF Cryobench facility, ID29S. Here, the current status of the beamline is described and plans for its future are briefly outlined.


Subject(s)