Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 22(10)2022 May 10.
Article in English | MEDLINE | ID: mdl-35632030

ABSTRACT

The article concerns the issue of non-invasive moisture sensing in building materials. Two techniques that enable evaluating the value of the relative permittivity of the material, being the measure of porous material moisture, have been utilized for the research. The first is the microwave technique that utilizes the non-contact measurement of velocity of microwave radiation across the tested material and the second is the time domain reflectometry (TDR) technique based on the measurement of electromagnetic pulse propagation time along the waveguides, being the elements of sensor design. The tested building material involved samples of red ceramic brick that differed in moisture, ranging between 0% and 14% moisture by weight. The main goal of the research was to present the measuring potential of both techniques for moisture evaluation as well as emphasize the advantages and disadvantages of each method. Within the research, it was stated that both methods provide similar measuring potential, with a slight advantage in favor of a microwave non-contact sensor over surface TDR sensor designs.


Subject(s)
Construction Materials , Microwaves , Porosity
2.
Sensors (Basel) ; 19(22)2019 Nov 06.
Article in English | MEDLINE | ID: mdl-31698878

ABSTRACT

Delay lines with a tunable length are used in a number of applications in the field of microwave techniques. The digitally-controlled analogue wideband delay line is particularly useful in noise radar applications as a precise detector of movement. In order to perform coherent reception in the noise radar, a delay line with a variable delay value is required. To address this issue, this paper comprises a new concept of a digitally-controlled delay line with a set of fine distance gates. In the paper, a solution for micro-movement detection is proposed, which is based on direct signal processing in the time domain with the use of a microwave analogue correlator. This concept assumes the use of a microwave analogue tapped delay line structure. It was found that the optimal solution for a noise radar with an analogue signal correlator is a combined delay line consisting of switched reference sections, a tapped delay line, and a precision phase shifter. The combined delay line presented in this paper is dedicated to serving as the adjustable reference delay for a noise radar intended for the detection of micro-movement. The paper contains the calculation results and delay line implementation for a given example. The new structure of the analogue tapped delay line with the calculation of optimal parameters is also presented. The precise detector of movement can be successfully used for the remote sensing of human vital signs (especially through-the-wall), e.g., breathing and heart beating, with the simultaneous determination of position.

3.
Sensors (Basel) ; 18(5)2018 May 06.
Article in English | MEDLINE | ID: mdl-29734772

ABSTRACT

Determination of the signal power-to-noise power ratio on the input and output of reception systems is essential to the estimation of their quality and signal reception capability. This issue is especially important in the case when both signal and noise have the same characteristic as Gaussian white noise. This article considers the problem of how a signal-to-noise ratio is changed as a result of signal processing in the correlation receiver of a noise radar in order to determine the ability to detect weak features in the presence of strong clutter-type interference. These studies concern both theoretical analysis and practical measurements of a noise radar with a digital correlation receiver for 9.2 GHz bandwidth. Firstly, signals participating individually in the correlation process are defined and the terms signal and interference are ascribed to them. Further studies show that it is possible to distinguish a signal and a noise on the input and output of a correlation receiver, respectively, when all the considered noises are in the form of white noise. Considering the above, a measurement system is designed in which it is possible to represent the actual conditions of noise radar operation and power measurement of a useful noise signal and interference noise signals—in particular the power of an internal leakage signal between a transmitter and a receiver of the noise radar. The proposed measurement stands and the obtained results show that it is possible to optimize with the use of the equipment and not with the complex processing of a noise signal. The radar parameters depend on its prospective application, such as short- and medium-range radar, ground-penetrating radar, and through-the-wall detection radar.

4.
IEEE Trans Biomed Eng ; 51(3): 548-51, 2004 Mar.
Article in English | MEDLINE | ID: mdl-15000388

ABSTRACT

This paper presents problems related to thermal radiation of human bodies in microwave range with respect to diagnosis of breast carcinoma. A mathematical model of thermal radiation transfer through tissues is introduced and methods of measurement of temperature, depth and size of a heat source, by means of multifrequency microwave thermograph are described. Theoretical considerations are supplemented by presentation of experimental results.


Subject(s)
Algorithms , Body Temperature/physiology , Diagnosis, Computer-Assisted/methods , Microwaves , Models, Biological , Radiometry/methods , Thermography/methods , Biomedical Engineering/methods , Computer Simulation , Diagnosis, Computer-Assisted/instrumentation , Radiometry/instrumentation , Thermography/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...