Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Toxicol ; 41(2): 89-98, 2022.
Article in English | MEDLINE | ID: mdl-35337210

ABSTRACT

Polysorbate 80 (PS80) functions as a dispersing agent or solubilizer in many pharmaceuticals, and as a stabilizer in biopharmaceuticals. Topical or parenteral administration of low doses of PS80 in biopharmaceuticals has been associated with mild allergic reactions, including local injection site reactions in humans. High doses of PS80, such as levels found in traditional Chinese herbal parenteral medicines, have been linked to systemic effects consistent with anaphylactoid-type reactions, which are characterized by the direct release of histamine from mast cells (degranulation). Nonclinical safety assessments of PS80 in vivo have mainly focused on canine model systems, a species established to be particularly sensitive to PS80. However, there is conflicting data about the dose and route of administration of PS80 required to elicit an anaphylactoid-type reaction in this model system. Therefore, studies using multiple dosing regimens in anesthetized and conscious dogs including a combination of cardiovascular data, clinical signs, and biomarkers of mast cell degranulation were conducted. An intravenous (IV) bolus of 1 mg/kg PS80 (0.25% w/v) elicited a positive anaphylactoid reaction including increased heart rate, hypotension, and clinical signs associated with anaphylactoid reactions (e.g., reddened muzzle). However, a full reaction was not observed with a subcutaneous (SC) injection of PS80 (0.25% w/v) up to 20 mg/kg and IV bolus or IV infusions up to 0.5 mg/kg. These data establish a threshold dose for eliciting an anaphylactoid reaction in canine which varies depending on the route of administration as well as the rate of PS80 infusion.


Subject(s)
Anaphylaxis , Anaphylaxis/chemically induced , Animals , Dogs , Histamine , Injections, Intravenous , Mast Cells , Polysorbates/toxicity
2.
Can J Neurol Sci ; 43(2): 254-60, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26864547

ABSTRACT

BACKGROUND: The StatNet electrode set is a system that can be applied by a non-electroencephalogram (EEG) technologist after minimal training. The primary objectives of this study are to assess the quality and reliability of the StatNet recordings in comparison to the conventional EEG. METHODS: Over 10 months, 19 patients with suspected nonconvulsive status epilepticus were included from university hospital emergency settings. Each patient received a StatNet EEG by a trained epilepsy fellow and a conventional EEG by registered technologists. We compared the studies in a blinded fashion, for the timeframe from EEG order to the setup time, start of acquisition, amount of artifact, and detection of abnormalities. The nonparametric Mann-Whitney two-sample t test was used for comparisons. The kappa score was used to assess reliability. RESULTS: Mean age of patients was 61±16.3 (25-93) years. The inter-observer agreement for detection of abnormal findings was 0.83 for StatNet and 0.75 for conventional EEG. Nonconvulsive status epilepticus was detected in 10% (2/19) in both studies. The delay from the time of EEG requisition to acquisition was shorter in the StatNet (22.4±2.5 minutes) than the conventional EEG (217.7±44.6 minutes; p<0.0001). The setup time was also shorter in the StatNet (9.9±0.8 minutes) compared with the conventional EEG (17.8±0.8 minutes; p<0.0001). There was no difference in the percentage of artifact duration between the two studies (p=0.89). CONCLUSION: This study demonstrates that StatNet EEG is a practical and reliable tool in the emergency setting, which reduces the delay of testing compared with conventional EEG, without significant compromise of study quality.


Subject(s)
Electroencephalography/methods , Status Epilepticus/diagnosis , Adult , Aged , Aged, 80 and over , Emergency Service, Hospital , Female , Humans , Male , Middle Aged , Reproducibility of Results , Signal Processing, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL
...