1.
Article in English | MEDLINE | ID: mdl-38795093

ABSTRACT

BACKGROUND: Left atrial appendage occlusion (LAAO) provides mechanical cardioembolic protection for atrial fibrillation (AF) patients who cannot use oral anticoagulation therapy (OAT). Patients with a thrombotic event despite OAT are at high risk for recurrence and may also benefit from LAAO. OBJECTIVES: This study sought to investigate the efficacy of LAAO in AF patients with a thrombotic event on OAT compared to: 1) LAAO in AF patients with a contraindication for OAT; and 2) historical data. METHODS: The international LAAO after stroke despite oral anticoagulation (STR-OAC LAAO) collaboration included patients who underwent LAAO because of thrombotic events on OAT. This cohort underwent propensity score matching and was compared to the EWOLUTION (Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology) registry, which represents patients who underwent LAAO because of OAT contraindications. The primary outcome was ischemic stroke. Event rates were compared between cohorts and with historical data without OAT, yielding relative risk reductions based on risk scores. RESULTS: Analysis of 438 matched pairs revealed no significant difference in the ischemic stroke rate between the STR-OAC LAAO and EWOLUTION cohorts (2.5% vs 1.9%; HR: 1.37; 95% CI: 0.72-2.61). STR-OAC LAAO patients exhibited a higher thromboembolic risk (HR: 1.71; 95% CI: 1.04-2.83) but lower bleeding risk (HR: 0.39; 95% CI: 0.18-0.88) compared to EWOLUTION patients. The mortality rate was slightly higher in EWOLUTION (4.3% vs 6.9%; log-rank P = 0.028). Relative risk reductions for ischemic stroke were 70% and 78% in STR-OAC LAAO and EWOLUTION, respectively, compared to historical data without OAT. CONCLUSIONS: LAAO in patients with a thrombotic event on OAT demonstrated comparable stroke rates to the OAT contraindicated population in EWOLUTION. The thromboembolic event rate was higher and the bleeding rate lower, reflecting the intrinsically different risk profile of both populations. Until randomized trials are available, LAAO may be considered in patients with an ischemic event on OAT.

3.
JACC Cardiovasc Interv ; 17(3): 374-387, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38180419

ABSTRACT

BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Pandemics , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/epidemiology , Treatment Outcome , COVID-19/epidemiology , Registries , Risk Factors
4.
Am Heart J ; 269: 158-166, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38163616

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment option for patients with severe aortic valve stenosis, but is still associated with relatively high rates of pacemaker implantation and paravalvular regurgitation. Routine preoperative computed tomography (CT) combined with patient-specific computer modelling can predict the interaction between the TAVI device and the patient's unique anatomy, allowing physicians to assess the risk for paravalvular regurgitation and conduction disorders in advance to the procedure. The aim of this trial is to assess potential improvement in the procedural outcome of TAVI by applying CT-based patient-specific computer simulations in patients with suitable anatomy for TAVI. METHODS: The GUIDE-TAVI trial is an international multicenter randomized controlled trial including patients accepted for TAVI by the Heart Team. Patients enrolled in the study will be randomized into 2 arms of each 227 patients. In patients randomized to the use of FEops HEARTGuide (FHG), patient-specific computer simulation with FHG is performed in addition to routine preoperative CT imaging and results of the FHG are available to the operator(s) prior to the scheduled intervention. In patients randomized to no use of FHG, only routine preoperative CT imaging is performed. The primary objective is to evaluate whether the use of FHG will reduce the incidence of mild to severe PVR, according to the Valve Academic Research Consortium 3. Secondary endpoints include the incidence of new conduction disorders requiring permanent pacemaker implantation, the difference between preoperative and final selected valve size, the difference between target and final implantation depth, change of preoperative decision, failure to implant valve, early safety composite endpoint and quality of life. CONCLUSIONS: The GUIDE-TAVI trial is the first multicenter randomized controlled trial to evaluate the value of 3-dimensional computer simulations in addition to standard preprocedural planning in TAVI procedures.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Computer Simulation , Quality of Life , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Tomography, X-Ray Computed/adverse effects , Treatment Outcome , Heart Valve Prosthesis/adverse effects
5.
Curr Probl Cardiol ; 49(1 Pt C): 102134, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37852558

ABSTRACT

This study evaluates the early and long-term clinical and echocardiographic outcome of edge-to-edge (E2E) mitral valve repair (MVr) concomitant to septal myectomy (SM) in patients with symptomatic hypertrophic obstructive cardiomyopathy (HOCM). A retrospective single-center analysis was performed of patients who underwent isolated SM or SM with E2E MVr from 2011 to 2022. Exclusion criteria were primary mitral valve (MV) disease or concomitant valve surgery. Early and long-term safety, functional and echocardiographic outcomes were compared between groups. Between January 2011 and April 2022, 76 consecutive patients underwent SM for HOCM: 42 patients (55%) underwent SM without additional E2E MVr (Group 1) and 34 patients (45%) underwent SM with additional E2E MVr (Group 2). At latest follow-up, 87% of patients were in New York Heart Association (NYHA) class I-II with no significant differences in NYHA class between groups. Incidence of safety events was comparable between groups. Echocardiographic relief of left ventricular outflow tract (LVOT) obstruction was comparable at early follow-up (P = 0.68), with a significant but small difference in maximum LVOT pressure gradient at latest follow-up in favor of E2E MVr (P = 0.04). Furthermore, patients who underwent SM with E2E MVr showed less residual systolic anterior motion at early and latest follow-up (P = 0.020; P = 0.178). Reintervention on the MV was absent in both groups at 1 year and equally low at follow-up (P = 0.27). This study demonstrates that adding E2E MVr to septal myectomy is as safe as isolated myectomy for the treatment of HOCM. Moreover, the addition of E2E MVr is associated with similar excellent functional improvement and freedom from MV reintervention.


Subject(s)
Cardiomyopathy, Hypertrophic , Heart Valve Diseases , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Retrospective Studies , Heart Septum/diagnostic imaging , Heart Septum/surgery , Treatment Outcome , Echocardiography , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cardiomyopathy, Hypertrophic/surgery
6.
J Cardiovasc Dev Dis ; 10(12)2023 Nov 24.
Article in English | MEDLINE | ID: mdl-38132642

ABSTRACT

BACKGROUND: Regional functional left ventricular (LV) assessment using current imaging techniques remains limited. Inward displacement (InD) has been developed as a novel technique to assess regional LV function via measurement of the regional displacement of the LV endocardial border across each of the 17 LV segments. Currently, normal ranges for InD are not available for clinical use. The aim of this study was to validate the normal reference limits of InD in healthy adults across all LV segments. METHODS: InD was analyzed in 120 healthy subjects with a normal LV ejection fraction, using the three standard long-axis views obtained during cardiac MRI that quantified the degree of inward endocardial wall motion towards the true LV center of contraction. For all LV segments, InD was measured in mm and expressed as a percentage of the theoretical degree of maximal segment contraction towards the true LV centerline. The arithmetic average InD was obtained for each of the 17 segments. The LV was divided into three regions, obtaining average InD at the LV base (segments 1-6), mid-cavity (segments 7-12) and apex (segments 13-17). RESULTS: Average InD was 33.4 ± 4.3%. InD was higher in basal and mid-cavity LV segments (32.8 ± 4.1% and 38.1 ± 5.8%) compared to apical LV segments (28.6 ± 7.7%). Interobserver variability correlations for InD were strong (R = 0.80, p < 0.0001). CONCLUSIONS: We provide clinically meaningful reference ranges for InD in subjects with normal LV function, which will emerge as an important screening and assessment imaging tool for a range of HFrEF therapies.

8.
Front Cardiovasc Med ; 10: 1227217, 2023.
Article in English | MEDLINE | ID: mdl-37645516

ABSTRACT

Background: A steep rise in the use of transcatheter aortic valve implantation (TAVI) for the management of symptomatic severe aortic stenosis occurred. Minimalist TAVI procedures and streamlined patient pathways within experienced Heart Valve Centres are designed to overcome the challenges of ever-increasing procedural volume. Aims: The 2022 European TAVI Pathway Survey aims to describe contemporary TAVI practice across Europe. Materials and methods: Between October and December 2022, TAVI operators from 32 European countries were invited to complete an online questionnaire regarding their current practice. Results: Responses were available from 147 TAVI centres in 26 countries. In 2021, the participating centres performed a total number of 27,223 TAVI procedures, with a mean of 185 TAVI cases per centre (median 138; IQR 77-194). Treatment strategies are usually (87%) discussed at a dedicated Heart Team meeting. Transfemoral TAVI is performed with local anaesthesia only (33%), with associated conscious sedation (60%), or under general anaesthesia (7%). Primary vascular access is percutaneous transfemoral (99%) with secondary radial access (52%). After uncomplicated TAVI, patients are transferred to a high-, medium-, or low-care unit in 28%, 52%, and 20% of cases, respectively. Time to discharge is day 1 (12%), day 2 (31%), day 3 (29%), or day 4 or more (28%). Conclusion: Reported adoption of minimalist TAVI techniques is common among European TAVI centres, but rates of next-day discharge remain low. This survey highlights the significant progress made in refining TAVI treatment and pathways in recent years and identifies possible areas for further improvement.

9.
JACC Cardiovasc Interv ; 16(15): 1889-1898, 2023 08 14.
Article in English | MEDLINE | ID: mdl-37587597

ABSTRACT

BACKGROUND: Left atrial appendage occlusion (LAAO) procedures are widely guided by standard transesophageal echocardiography (TEE) probes, requiring general anesthesia in most patients. The use of miniaturized TEE probes allows for LAAO guidance under local anesthesia and offers an attractive imaging alternative to standard TEE probes. OBJECTIVES: The aim of this study was to assess the safety and efficacy of miniaturized TEE probes for procedural guidance of LAAO. METHODS: Multicenter retrospective observational study of LAAO procedures performed under miniaturized TEE guidance and conscious sedation. The primary efficacy endpoint was technical success. The secondary efficacy endpoint was procedural success (technical success without major periprocedural complications). The safety outcome was a composite of major periprocedural complications. RESULTS: A total of 546 consecutive LAAO procedures were performed in 5 European centers. Technical success was achieved in 534 (98.0%) patients. Sixteen major periprocedural complications occurred in 15 (2.9%) patients, yielding a procedural success rate of 97.0%. Conversion to general anesthesia was required in 4 (0.7%) patients. Short-term imaging follow-up was available in 422 patients with an incidence of major (>5 mm) TEE-detected residual leaks of 0.7%, complete LAA occlusion of 82.2% on cardiac computed tomography, and device-related thrombus of 5%. As compared with procedural 2-dimensional imaging for device sizing, preprocedural assessment by 3-dimensional imaging resulted in improved technical success (100% vs 95.0%; P < 0.001). CONCLUSIONS: LAAO under conscious sedation and miniaturized TEE guidance is safe and feasible with a high rate of technical success and a low rate of periprocedural complications.


Subject(s)
Atrial Appendage , Echocardiography, Transesophageal , Humans , Conscious Sedation/adverse effects , Atrial Appendage/diagnostic imaging , Treatment Outcome , Anesthesia, General
10.
EuroIntervention ; 19(9): 766-771, 2023 Nov 17.
Article in English | MEDLINE | ID: mdl-37605804

ABSTRACT

About one-third of patients undergoing transcatheter aortic valve implantation (TAVI) use oral anticoagulants (OAC), mainly due to atrial fibrillation. General guidelines advise interrupting OAC in patients with a high risk of bleeding undergoing interventions. However, preliminary observational data suggest that the continuation of OAC during TAVI is safe and may reduce the risk of periprocedural thromboembolic events. The Periprocedural Continuation Versus Interruption of Oral Anticoagulant Drugs During Transcatheter Aortic Valve Implantation (POPular PAUSE TAVI) is a multicentre, randomised clinical trial with open-label treatment and blinded endpoint assessment. Patients are randomised 1:1 to periprocedural continuation versus interruption of OAC and are stratified for vitamin K antagonist or direct oral anticoagulant use. The primary endpoint is a composite of cardiovascular mortality, all stroke, myocardial infarction, major vascular complications and type 2-4 bleeding within 30 days after TAVI, according to the Valve Academic Research Consortium-3 criteria. Secondary endpoints include separate individual and composite outcomes, quality of life and cost-effectiveness. Since continuation of OAC is associated with the ancillary benefit that it simplifies periprocedural management, the primary outcome is first analysed for non-inferiority; if non-inferiority is proven, superiority will be tested. Recruitment started in November 2020, and the trial will continue until a total of 858 patients have been included and followed for 90 days. In summary, POPular PAUSE TAVI is the first randomised clinical trial to assess the safety and efficacy of periprocedural continuation versus interruption of OAC in patients undergoing TAVI.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Quality of Life , Anticoagulants/therapeutic use , Hemorrhage , Treatment Outcome , Aortic Valve/surgery , Risk Factors
11.
Heart Rhythm O2 ; 4(5): 298-308, 2023 May.
Article in English | MEDLINE | ID: mdl-37323993

ABSTRACT

Background: Percutaneous left atrial appendage occlusion (LAAO) is an alternative to anticoagulation in the prevention of stroke in patients with nonvalvular atrial fibrillation, especially in patients with a contraindication for oral anticoagulation therapy (OAT). Objective: The study sought to obtain long-term patient outcomes after successful LAAO in everyday clinical practice. Methods: In this single-center registry spanning over 10 years, data of all consecutive patients that underwent percutaneous LAAO were collected. Observed thromboembolic and major bleeding event rates after successful LAAO during follow-up were compared with expected event rates based on CHA2DS2-VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category) and HAS-BLED (hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol) scores. Furthermore, anticoagulation and antiplatelet use during follow-up was evaluated. Results: Of 230 patients scheduled for LAAO (38% women, 69.5 ± 8.2 years of age, CHA2DS2-VASc score 3.9 ± 1.6, HAS-BLED score 2.9 ± 1.0), 218 patients had a successful implantation (95%) with a follow-up duration of 5.2 ± 3.1 years. The procedure was combined with catheter ablation in 52% of the patients. Fifty thromboembolic complications (24 ischemic stroke, 26 transient ischemic attack) were observed during follow-up in 40 (18%) of 218 patients. Ischemic strokes occurred with a rate of 2.1 per 100 patient-years, accounting for a 66% relative risk reduction compared with the CHA2DS2-VASc predicted event rate. Device-related thrombus was observed in 5 (2%) patients. Sixty-five nonprocedural major bleeding complications occurred in 24 (11%) of 218 patients with a rate of 5.7 per 100-patient years, which is comparable to estimated HAS-BLED-bleeding rates under OAT use. At end of follow-up 71% of all patients were on single antiplatelet or no antiplatelet or anticoagulation treatment, while 29% were on OAT. Conclusion: Thromboembolic event rates during long-term follow-up after successful LAAO remained consistently lower than expected supporting the efficacy of LAAO.

12.
Neth Heart J ; 31(10): 383-389, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37256540

ABSTRACT

BACKGROUND: Postsurgical thoracic aortic pseudoaneurysms (PTAPs) are a potentially lethal complication after cardiac or aortic surgery. Surgical management can pose a challenge with high in-hospital mortality rates. Transcatheter closure is a less-invasive alternative treatment option for selected patients, although current experience is limited. AIMS: We aimed to evaluate procedural and imaging outcomes of our first 11 cases of transcatheter PTAP closure with the use of closure devices. METHODS: Patients with a high operative risk who underwent transcatheter PTAP closure at our centre from 2019 to 2021 were retrospectively included. Suitability was evaluated on preprocedural computed tomography (CT) scans and three-dimensional (3D) reconstructions. All procedures were performed in the catheterisation laboratory. Intraprocedural aortography and postprocedural CT scans with 3D reconstructions were used to evaluate PTAP occlusion. RESULTS: Eleven consecutive patients with a high operative risk and a history of cardiac/aortic surgery who underwent transcatheter PTAP closure were included. PTAPs were predominantly located at the proximal or distal anastomosis of a supracoronary ascending aortic vascular graft or Bentall prosthesis (82%). Implanted closure devices included Amplatzer Valvular Plug III (82%), Amplatzer septal occluder (9%) and Occlutech atrial septal defect occluder (9%). No periprocedural complications occurred. After device deployment, residual flow was absent on aortography in 64% and minimal residual flow was present in 36% of patients. Subtotal or total occlusion of the PTAP on follow-up CT ranged between 45% and 73%. CONCLUSIONS: Although subtotal or total occlusion of the PTAP was found at follow-up in only 45-73% of cases, transcatheter PTAP closure guided by preprocedural 3D reconstructions can offer a valuable minimally invasive primary treatment option for patients who otherwise would face a high-risk reoperation.

13.
Curr Med Sci ; 43(3): 423-433, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37055655

ABSTRACT

New non- and less-invasive techniques have been developed to overcome the procedural and operator related burden of the fractional flow reserve (FFR) for the assessment of potentially significant stenosis in the coronary arteries. Virtual FFR-techniques can obviate the need for the additional flow or pressure wires as used for FFR measurements. This review provides an overview of the developments and validation of the virtual FFR-algorithms, states the challenges, discusses the upcoming clinical trials, and postulates the future role of virtual FFR in the clinical practice.


Subject(s)
Coronary Stenosis , Fractional Flow Reserve, Myocardial , Humans , Coronary Stenosis/diagnostic imaging , Coronary Angiography/methods , Predictive Value of Tests , Coronary Vessels/diagnostic imaging
14.
Eur Radiol ; 33(8): 5465-5475, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36920521

ABSTRACT

OBJECTIVES: The addition of CT-derived fractional flow reserve (FFR-CT) increases the diagnostic accuracy of coronary CT angiography (CCTA). We assessed the impact of FFR-CT in routine clinical practice on clinical decision-making and patient prognosis in patients suspected of stable coronary artery disease (CAD). METHODS: This retrospective, single-center study compared a cohort that received CCTA with FFR-CT to a historical cohort that received CCTA before FFR-CT was available. We assessed the clinical management decisions after FFR-CT and CCTA and the rate of major adverse cardiac events (MACEs) during the 1-year follow-up using chi-square tests for independence. Kaplan-Meier curves were used to visualize the occurrence of safety outcomes over time. RESULTS: A total of 360 patients at low to intermediate risk of CAD were included, 224 in the CCTA only group, and 136 in the FFR-CT group. During follow-up, 13 MACE occurred in 12 patients, 9 (4.0%) in the CCTA group, and three (2.2%) in the FFR-CT group. Clinical management decisions differed significantly between both groups. After CCTA, 60 patients (26.5%) received optimal medical therapy (OMT) only, 115 (51.3%) invasive coronary angiography (ICA), and 49 (21.9%) single positron emission CT (SPECT). After FFR-CT, 106 patients (77.9%) received OMT only, 27 (19.9%) ICA, and three (2.2%) SPECT (p < 0.001 for all three options). The revascularization rate after ICA was similar between groups (p = 0.15). However, patients in the CCTA group more often underwent revascularization (p = 0.007). CONCLUSION: Addition of FFR-CT to CCTA led to a reduction in (invasive) diagnostic testing and less revascularizations without observed difference in outcomes after 1 year. KEY POINTS: • Previous studies have shown that computed tomography-derived fractional flow reserve improves the accuracy of coronary computed tomography angiography without changes in acquisition protocols. • This study shows that use of computed tomography-derived fractional flow reserve as gatekeeper to invasive coronary angiography in patients suspected of stable coronary artery disease leads to less invasive testing and revascularization without observed difference in outcomes after 1 year. • This could lead to a significant reduction in costs, complications and (retrospectively unnecessary) usage of diagnostic testing capacity, and a significant increase in patient satisfaction.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Computed Tomography Angiography/methods , Retrospective Studies , Coronary Stenosis/diagnosis , Coronary Angiography/methods , Tomography, X-Ray Computed , Prognosis , Clinical Decision-Making , Predictive Value of Tests
15.
J Clin Med ; 12(5)2023 Mar 02.
Article in English | MEDLINE | ID: mdl-36902783

ABSTRACT

BACKGROUND: Hybrid minimally invasive left ventricular reconstruction is used to treat patients with ischemic heart failure with reduced ejection fraction (HFrEF) and antero-apical scar. Pre- and post-procedural regional functional left ventricular assessment with current imaging techniques remains limited. We evaluated 'inward displacement' as a novel technique of assessing regional left ventricular function in an ischemic HFrEF population who underwent left ventricular reconstruction with the Revivent System. METHODS: Inward displacement adopts three standard long-axis views obtained during cardiac MRI or CT and assesses the degree of inward endocardial wall motion towards the true left ventricular center of contraction. For each of the standard 17 left ventricular segments, regional inward displacement is measured in mm and expressed as a percentage of the maximal theoretical distance each segment can contract towards the centerline. The left ventricle was divided into three regions, obtaining the arithmetic average of inward displacement or speckle tracking echocardiographic strain at the left ventricular base (segments 1-6), mid-cavity (segments 7-12) and apex (segments 13-17). Inward displacement was measured using computed tomography or cardiac magnetic resonance imaging and compared pre- and post-procedurally in ischemic HFrEF patients who underwent left ventricular reconstruction with the Revivent System (n = 36). In a subset of patients who underwent baseline speckle tracking echocardiography, pre-procedural inward displacement was compared with left ventricular regional echocardiographic strain (n = 15). RESULTS: Inward displacement of basal and mid-cavity left ventricular segments increased by 27% (p < 0.001) and 37% (p < 0.001), respectively, following left ventricular reconstruction. A significant overall decrease in both the left ventricular end systolic volume index and end diastolic volume index of 31% (p < 0.001) and 26% (p < 0.001), respectively, was detected, along with a 20% increase in left ventricular ejection fraction (p = 0.005). A significant correlation between inward displacement and speckle tracking echocardiographic strain was noted within the basal (R = -0.77, p < 0.001) and mid-cavity left ventricular segments (R = -0.65, p = 0.004), respectively. Inward displacement resulted in relatively larger measurement values compared to speckle tracking echocardiography, with a mean difference of absolute values of -3.33 and -7.41 for the left ventricular base and mid-cavity, respectively. CONCLUSIONS: Obviating the limitations of echocardiography, inward displacement was found to highly correlate with speckle tracking echocardiographic strain to evaluate regional segmental left ventricular function. Significant improvements in basal and mid-cavity left ventricular contractility were demonstrated in ischemic HFrEF patients following left ventricular reconstruction of large antero-apical scars, consistent with the concept of reverse left ventricular remodeling at a distance. Inward displacement holds significant promise in the HFrEF population being evaluated pre- and post-left ventriculoplasty procedures.

16.
EuroIntervention ; 18(12): 957-976, 2023 Jan 23.
Article in English | MEDLINE | ID: mdl-36688459

ABSTRACT

Mitral regurgitation (MR) is the most prevalent valvular heart disease and, when left untreated, results in reduced quality of life, heart failure, and increased mortality. Mitral valve transcatheter edge-to-edge repair (M-TEER) has matured considerably as a non-surgical treatment option since its commercial introduction in Europe in 2008. As a result of major device and interventional improvements, as well as the accumulation of experience by the interventional cardiologists, M-TEER has emerged as an important therapeutic strategy for patients with severe and symptomatic MR in the current European and American guidelines. Herein, we provide a comprehensive up-do-date overview of M-TEER. We define preprocedural patient evaluation and highlight key aspects for decision-making. We describe the currently available M-TEER systems and summarise the evidence for M-TEER in both primary mitral regurgitation (PMR) and secondary mitral regurgitation (SMR). In addition, we provide recommendations for device selection, intraprocedural imaging and guiding, M-TEER optimisation and management of recurrent MR. Finally, we provide information on major unsolved questions and "grey areas" in M-TEER.


Subject(s)
Cardiac Surgical Procedures , Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Quality of Life , Treatment Outcome
17.
Eur J Cardiothorac Surg ; 63(4)2023 04 03.
Article in English | MEDLINE | ID: mdl-36571500

ABSTRACT

Interventricular septum defects are a known complication after an aortic valve replacement, but not after mitral surgery. We present a case of a 65-year-old female who underwent unsuccessful mitral valvuloplasty through port-access surgery, followed by uneventful mechanical bioprosthesis replacement. Postoperatively, the patient experienced multiple arrhythmias and recovered poorly. A systolic murmur led to echocardiography, showing an interventricular septum rupture. This was closed with 2 polypropylene pledgeted mattress sutures, via the right atrium and tricuspid valve through midsternal access. The authors believe that the most likely cause is tearing of 2 deeply placed adjacent sutures in the septum, creating localized weakening of the septum susceptible to further rupture. We therefore underline the importance of adequate exposure, especially at the notorious anterior annulus.


Subject(s)
Heart Septal Defects, Ventricular , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Female , Humans , Aged , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/surgery , Echocardiography
18.
JACC Cardiovasc Interv ; 15(11): 1140-1149, 2022 06 13.
Article in English | MEDLINE | ID: mdl-35680194

ABSTRACT

BACKGROUND: The work-up for transcatheter aortic valve replacement (TAVR) currently uses computed tomography to evaluate the annulus diameter and peripheral vascular access plus invasive coronary angiography (ICA) to assess significant coronary artery disease (CAD). ICA might partially be redundant with the use of coronary computed tomography angiography (CCTA). Prior studies found an improvement of the diagnostic accuracy of CCTA with the use of computed tomography-derived fractional flow reserve (CT-FFR). OBJECTIVES: The aim of this study was to assess the diagnostic performance of CT-FFR for the diagnosis of CAD in the work-up for TAVR. METHODS: Consecutive patients with severe symptomatic aortic valve stenosis who underwent TAVR work-up between 2015 and 2019 were included in this retrospective cross-sectional study. All patients underwent CCTA and ICA within 3 months, and the diagnostic performance of both CCTA and CT-FFR was assessed using ICA as the reference. RESULTS: Seventy-six of the 338 patients included in the analysis had ≥1 significant coronary stenosis on ICA. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy per patient were 76.9%, 64.5%, 34.0%, 92.1%, and 66.9% for CCTA and 84.6%, 88.3%, 63.2%, 96.0%, and 87.6% for CT-FFR. The area under the receiver-operating characteristic curve was significantly different between CCTA and CT-FFR (0.84 vs 0.90, P = 0.02). A CT-FFR-guided approach could avoid ICA in 57.1% versus 43.6% of patients using CCTA. CONCLUSIONS: CT-FFR significantly improves the diagnostic accuracy of CCTA without additional testing and increases the proportion of patients in whom ICA could have been safely avoided. It has the potential to be integrated in the current clinical work-up for TAVR for diagnosing stable CAD requiring treatment.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Transcatheter Aortic Valve Replacement , Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Artery Disease/diagnosis , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/therapy , Cross-Sectional Studies , Humans , Predictive Value of Tests , Retrospective Studies , Tomography, X-Ray Computed , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
19.
Front Cardiovasc Med ; 9: 850700, 2022.
Article in English | MEDLINE | ID: mdl-35497995

ABSTRACT

Degenerative mitral regurgitation (DMR) based on posterior leaflet prolapse is the most frequent type of organic mitral valve disease and has proven to be durably repairable in most cases by chordal repair techniques either by conventional median sternotomy or by less invasive approaches both utilizing extracorporeal circulation and cardioplegic myocardial arrest. Recently, several novel transapical chordal repair techniques specifically targeting the posterior leaflet have been developed as a far less invasive and beating heart (off-pump) alternative to port-access mitral repair. In order to perform a safe and effective minimally invasive mitral chordal repair, thorough knowledge of the anatomy of the mitral valve apparatus and adequate use of multimodality imaging both pre- and intraoperatively are fundamental. In addition, comprehensive understanding of the available novel devices, their delivery systems and the individual procedural steps are required.

20.
Struct Heart ; 6(5): 100081, 2022 Oct.
Article in English | MEDLINE | ID: mdl-37288056

ABSTRACT

Background: Left ventricular (LV) remodeling after anterior myocardial infarction (AMI) can cause a pathological increase in LV volume, reduction in LV ejection fraction (EF), and symptomatic heart failure (HF). This study evaluates the midterm results of a hybrid transcatheter and minimally invasive surgical technique to reconstruct the negatively remodeled LV by myocardial scar plication and exclusion with microanchoring technology. Methods: Retrospective single-center analysis of patients who underwent hybrid LV reconstruction (LVR) with the Revivent TransCatheter System. Patients were accepted for the procedure when they presented with symptomatic HF (New York Heart Association class ≥ II, EF < 40%) after AMI, in the presence of a dilated LV with either akinetic or dyskinetic scar in the anteroseptal wall and/or apex of ≥50% transmurality. Results: Between October 2016 and November 2021, 30 consecutive patients were operated. Procedural success was 100%. Comparing echocardiographic data preoperatively and directly postoperatively, LVEF increased from 33 ± 8% to 44 ± 10% (p < 0.0001). LV end-systolic volume index decreased from 58 ± 24 mL/m2 to 34 ± 19 mL/m2 (p < 0.0001) and LV end-diastolic volume index decreased from 84 ± 32 mL/m2 to 58 ± 25 mL/m2 (p < 0.0001). Hospital mortality was 0%. After a mean follow-up of 3.4 ± 1.3 years, there was a significant improvement of New York Heart Association class (p = 0.001) with 76% of surviving patients in class I-II. Conclusions: Hybrid LVR for symptomatic HF after AMI is safe and results in significant improvement in EF, reduction in LV volumes, and sustained improvement in symptoms.