Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
J Vasc Access ; 22(3): 450-456, 2021 May.
Article in English | MEDLINE | ID: mdl-32648805

ABSTRACT

Cannulation is essential for haemodialysis with arteriovenous access, but also damages the arteriovenous access making it prone to failure, is associated with complications and affects patients' experiences of haemodialysis. Managing Access by Generating Improvements in Cannulation is a national UK quality improvement project, designed to improve cannulation practice in the United Kingdom, ensuring it reflects current needling recommendations. It uses a simple quality improvement method, the Model for Improvement, to structure improvement to cannulation practice. It assists units in the practical implementation of the British Renal Society and Vascular Access Society of Britain and Ireland needling recommendations, ensuring actual cannulation practice reflects what is defined as best practice in cannulation. An eLearning package and awareness materials have been developed, to assist units in changing their cannulation practice. The Kidney Quality Improvement Partnership provides a structure for Managing Access by Generating Improvements in Cannulation that promotes development and dissemination. It is hoped that Managing Access by Generating Improvements in Cannulation will raise an understanding about the cannulation of arteriovenous access and change behaviours and beliefs around correct cannulation practice, to ensure longevity of this lifeline.


Subject(s)
Arteriovenous Shunt, Surgical/standards , Blood Vessel Prosthesis Implantation/standards , Catheterization/standards , Outcome and Process Assessment, Health Care/standards , Quality Improvement/standards , Quality Indicators, Health Care/standards , Renal Dialysis/standards , Arteriovenous Shunt, Surgical/adverse effects , Attitude of Health Personnel , Benchmarking/standards , Blood Vessel Prosthesis Implantation/adverse effects , Catheterization/adverse effects , Clinical Competence/standards , Health Knowledge, Attitudes, Practice , Humans , Inservice Training/standards , Program Evaluation , Time Factors , Treatment Outcome , United Kingdom
2.
BMJ ; 339: b2655, 2009 Jul 28.
Article in English | MEDLINE | ID: mdl-19638650

ABSTRACT

OBJECTIVE: To evaluate the performance of a rapid test for chlamydia with first void male urine samples as a potential tool for diagnosis and screening of chlamydial infection in men. DESIGN: Evaluation of test performance in prospective cohort study. Settings A young people's sexual health centre (site 1) and a genitourinary medicine clinic (site 2) in the United Kingdom. PARTICIPANTS: 1211 men aged 16-73 attending either of the two sites. MAIN OUTCOME MEASURES: Sensitivity, specificity, positive predictive value, and negative predictive value of the Chlamydia Rapid Test versus polymerase chain reaction assay. Relation between the visual signal of the Chlamydia Rapid Test and organism load. RESULTS: Detection rates for Chlamydia trachomatis infection with polymerase chain reaction were 4.4% (20/454) at site 1 and 11.9% (90/757) at site 2. Compared with polymerase chain reaction assay, the resolved sensitivity, specificity, positive predictive value, and negative predictive value of the Chlamydia Rapid Test was 82.6% (90/109), 98.5% (1085/1102), 84.1% (90/107), and 98.3% (1085/1104), respectively. The organism load in first void urine samples that were positive for chlamydia ranged from 7.28x10(2) to 6.93x10(6) plasmids/ml and correlated significantly with the visual signal of the Chlamydia Rapid Test (r=0.7897, P<0.001). CONCLUSIONS: The performance of the new Chlamydia Rapid Test with first void male urine samples indicates that it would be an effective diagnostic tool for chlamydial infection in men. The availability of test results within an hour allows for immediate treatment and contact tracing, potentially reducing the risks of persistent infection and onward transmission. The test could also provide a simple and reliable alternative to nucleic acid amplification assays for testing of male urine in chlamydial screening programmes in high prevalence settings.


Subject(s)
Chlamydia Infections/diagnosis , Urinalysis/standards , Adolescent , Adult , Aged , Chlamydia Infections/psychology , Humans , Male , Middle Aged , Patient Satisfaction , Polymerase Chain Reaction , Prospective Studies , Reagent Strips , Sensitivity and Specificity , Urinalysis/psychology , Young Adult
3.
BMJ ; 335(7631): 1190-4, 2007 Dec 08.
Article in English | MEDLINE | ID: mdl-18055487

ABSTRACT

OBJECTIVE: To evaluate the performance of a new Chlamydia Rapid Test with vaginal swab specimens as a potential tool for chlamydia diagnosis and screening. DESIGN: Performance evaluation study. Settings A young people's sexual health centre (site 1) and two genitourinary medicine clinics (sites 2 and 3) in the United Kingdom. PARTICIPANTS: 1349 women aged between 16 and 54 attending one of the three clinics. MAIN OUTCOME MEASURES: Sensitivity, specificity, positive predictive value, and negative predictive value of the Chlamydia Rapid Test versus polymerase chain reaction and strand displacement amplification assays; correlation between the Chlamydia Rapid Test visual signal and organism load; acceptability to participants of self collected vaginal swabs as the specimen type for Chlamydia testing. RESULTS: Polymerase chain reaction positivity rates for Chlamydia trachomatis infection were 8.4% (56/663) at site 1, 9.4% (36/385) at site 2, and 6.0% (18/301) at site 3. Compared with polymerase chain reaction assay, the resolved sensitivity, specificity, positive predictive value, and negative predictive value of the Chlamydia Rapid Test were 83.5% (91/109), 98.9% (1224/1238), 86.7% (91/105), and 98.6% (1224/1242). Compared with strand displacement amplification assay, sensitivity and specificity of the Chlamydia Rapid Test were 81.6% (40/49) and 98.3% (578/588). Organism load of self collected vaginal swabs ranged from 5.97x10(2) to 1.09x10(9) Chlamydia plasmids per swab, which correlated well with the Chlamydia Rapid Test's visual signal (r=0.6435, P<0.0001). Most (95.9%) surveyed participants felt comfortable about collecting their own swabs. CONCLUSIONS: The performance of the Chlamydia Rapid Test with self collected vaginal swabs indicates that it would be an effective same day diagnostic and screening tool for Chlamydia infection in women. The availability of Chlamydia Rapid Test results within 30 minutes allows for immediate treatment and contact tracing, potentially reducing the risks of persistent infection and onward transmission. It could also provide a simple and reliable alternative to nucleic acid amplification tests in chlamydia screening programmes.


Subject(s)
Chlamydia Infections/diagnosis , Point-of-Care Systems/standards , Adolescent , Adult , Chlamydia Infections/prevention & control , DNA, Bacterial/analysis , Female , Humans , Microbiological Techniques/standards , Middle Aged , Patient Satisfaction , Polymerase Chain Reaction , Specimen Handling , Vaginal Smears/standards
SELECTION OF CITATIONS