Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Oral Maxillofac Pathol ; 24(2): 368-373, 2020.
Article in English | MEDLINE | ID: mdl-33456249

ABSTRACT

Embryonic stem cells provide their major contribution to embryogenesis through formation of germ layers as they have pluripotency potential and capacity for self-renewal. Retention of pluripotency of these stem cells depends on expression/level of transcription factors, i.e., SOX2, OCT4 and NANOG. During organogenesis, the altered expression of the molecules also influences these stem cells to lose their pluripotency and turn toward the lineage selection. As the differentiation progresses, the maintenance of the somatic cells including the oral squamous cells also depends on differential expression of the transcription factors to some extent. Recently, many experimental and observational studies documented the significant contribution in carcinogenesis of various human cancers. In this review, we have attempted to summarize the evidences indicating about the putative role of these master pluripotency regulators in various phases of oral carcinogenesis i.e. initiation , progression and prognosis of oral squamous cell carcinoma.

2.
Rev Sci Instrum ; 87(7): 074708, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27475582

ABSTRACT

The wireless drive of an automated implantable electronic sensor has been explored for health monitoring applications. The proposed system comprises of an automated biomedical sensing system which is energized through resonant inductive coupling. The implantable sensor unit is able to monitor the body temperature parameter and sends back the corresponding telemetry data wirelessly to the data recoding unit. It has been observed that the wireless power delivery system is capable of energizing the automated biomedical implantable electronic sensor placed over a distance of 3 cm from the power transmitter with an energy transfer efficiency of 26% at the operating resonant frequency of 562 kHz. This proposed method ensures real-time monitoring of different human body temperatures around the clock. The monitored temperature data have been compared with a calibrated temperature measurement system to ascertain the accuracy of the proposed system. The investigated technique can also be useful for monitoring other body parameters such as blood pressure, bladder pressure, and physiological signals of the patient in vivo using various implantable sensors.


Subject(s)
Electrodes, Implanted , Models, Theoretical , Monitoring, Physiologic , Wireless Technology/instrumentation , Humans , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...