Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Knee Surg Sports Traumatol Arthrosc ; 23(4): 1206-14, 2015 Apr.
Article in English | MEDLINE | ID: mdl-24651978

ABSTRACT

PURPOSE: Anatomic placement of anterior cruciate ligament (ACL) grafts at arthroscopic reconstruction can be challenging. Localising ACL attachments on magnetic resonance imaging (MRI) sequences pre-operatively could aid with planning for anatomic graft placement. Though ACL attachments can be identified on two-dimensional (2D) MRI, slice thickness theoretically limits out-of-plane accuracy and a 3D MRI base sequence with smaller isotropic voxels may improve observer reliability in localising ACL attachment locations. The purpose of this study was to test whether a high-resolution 3D sequence improved inter- and intra-observer reliability of ACL attachment localisation compared with conventional 2D MRI for this application. METHODS: Twenty paediatric knees were retrospectively scanned at 1.5 Tesla with multi-planar 2D proton density (slice thickness 3-4 mm) and T2-weighted 3D multiple-echo data image combination gradient echo (isotropic 0.8 mm voxels) sequences. Two observers blinded to each others' findings identified ACL attachments on MRI slices, and 3D reconstructions showing ACL attachments were produced. ACL attachment centre locations and areas were calculated, and reliability assessed. RESULTS: Inter-observer variation of centre locations of ACL attachments identified on 3D versus 2D sequences was not significantly different (mean ± SD): 1.8 ± 0.6 versus 1.5 ± 0.7 mm at femoral attachments, 1.7 ± 0.7 versus 1.5 ± 0.8 mm at tibial attachments (p > 0.05). The 95 % confidence interval for centre locations was <4.0 mm in all cases. Inter-observer reliability of attachment areas was not higher for 3D sequences. CONCLUSIONS: ACL attachment centres were localised with high and similar inter- and intra-observer reliability on a high-resolution 3D and multi-planar conventional 2D sequences. Using this technique, MRI could potentially be used for planning and intra-operative guidance of anatomic ACL reconstruction, whether from 2D or 3D base sequences. Surgeons in clinical practice need not order a lengthy dedicated 3D MRI to localise ligament attachments, but can confidently use a standard 2D MRI for this application. LEVEL OF EVIDENCE: III.


Subject(s)
Anterior Cruciate Ligament Reconstruction , Anterior Cruciate Ligament/pathology , Imaging, Three-Dimensional/methods , Knee Injuries/diagnosis , Magnetic Resonance Imaging/methods , Adolescent , Anterior Cruciate Ligament/surgery , Anterior Cruciate Ligament Injuries , Child , Humans , Knee Injuries/surgery , ROC Curve , Reproducibility of Results , Retrospective Studies
2.
Am J Sports Med ; 42(7): 1644-51, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24755252

ABSTRACT

BACKGROUND: To aid in performing anatomic physeal-sparing anterior cruciate ligament (ACL) reconstruction, it is important for surgeons to have reference data for the native ACL attachment positions and epiphyseal anatomy in skeletally immature knees. PURPOSE: To characterize anatomic parameters of the ACL tibial insertion and proximal tibial epiphysis at magnetic resonance imaging (MRI) in a large population of skeletally immature knees. STUDY DESIGN: Cross-sectional study; Level of evidence, 3. METHODS: The ACL tibial attachment site and proximal epiphysis were examined in 570 skeletally immature knees with an intact ACL (age, 6-15 years) using 1.5-T proton density-weighted sagittal MRI; also measured were the tibial anteroposterior diameter; anterior, central, and posterior ACL attachment positions; vertical height of the epiphysis; and maximum oblique epiphyseal depth extending from the ACL tibial attachment center to the tibial tuberosity. RESULTS: In adolescents (11-15 years of age), the center of the ACL's tibial attachment was 51.5% ± 5.7% of the anteroposterior diameter of the tibia, with no significant differences between sexes or age groups (P > .05 in all cases). Mean vertical epiphyseal height was 15.9 ± 1.7 mm in the adolescent group, with significant differences between 11-year-olds (15.2 ± 1.5 mm) and 15-year-olds (16.6 ± 1.6 mm), P < .001, and between males (16.6 ± 1.5 mm) and females (14.8 ± 1.4), P < .001. Mean maximum oblique depth was 30.0 ± 5.3 mm, with a significant difference between 11-year-olds (26.7 ± 4.9 mm) and 15-year-olds (32.7 ± 5.1 mm), P < .001, and between males (29.7 ± 6.4 mm) and females (27.8 ± 5.2 mm), P < .001. The maximum oblique depth occurred at a mean angle of ~50°, and this angle did not change with age or sex. There was a significant moderate correlation (r = 0.39, P < .001) between epiphyseal vertical height and maximum oblique depth. CONCLUSION: The center of the ACL tibial attachment was consistently near 51% of the anteroposterior diameter, regardless of age or sex. The vertical depth of the tibial epiphysis was ~16 mm in adolescents. Maximum oblique depth from ACL attachment was ~30 mm, occurring at a mean angle ~50° regardless of age or sex. The normative values for tibial ACL attachment and epiphyseal anatomy presented here may be helpful in selecting candidates for surgery and in planning surgical approaches for pediatric ACL reconstruction.


Subject(s)
Anterior Cruciate Ligament Reconstruction/methods , Anterior Cruciate Ligament/anatomy & histology , Femur/anatomy & histology , Knee Joint/anatomy & histology , Adolescent , Anterior Cruciate Ligament/growth & development , Child , Cross-Sectional Studies , Epiphyses/anatomy & histology , Female , Femur/growth & development , Humans , Knee Joint/growth & development , Magnetic Resonance Imaging , Male , Reference Values , Tibia/anatomy & histology , Tibia/growth & development
3.
Arthroscopy ; 29(12): 1954-62, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24286795

ABSTRACT

PURPOSE: To determine whether 3-dimensional notch volume, measured with magnetic resonance imaging (MRI), differs significantly between knees with torn and intact anterior cruciate ligaments (ACLs) after sports injury in a skeletally immature pediatric population. METHODS: MRI studies of 50 pediatric patients (age range, 10 to 17 years) with ACL tears were compared with 50 age- and sex-matched intact-ACL control patients. All patients had open physes and underwent MRI after a sports injury. Notch volume was calculated through manual segmentation of notch boundaries seen on axial 1.5-T proton density-weighted images. Two-dimensional (2D) measurements (notch width and notch width index) were made on coronal proton density-weighted MRI studies. Notch volume was compared between groups by use of the Mann-Whitney U test. Pearson correlation coefficients were also calculated between indices. RESULTS: Notch volume was significantly lower in knees with ACL tears than in control knees (5.5 ± 1.1 cm(3)v 6.4 ± 1.5 cm(3), P = .002), whereas 2D notch width and notch width index did not differ significantly between these groups. Girls had significantly smaller notch volumes than boys (5.4 ± 1.2 cm(3)v 6.5 ± 1.3 cm(3), P < .001). Notch volume was not correlated with age but was moderately correlated with 2D notch width (r = 0.485, P < .001). CONCLUSIONS: In adolescent patients with sports injuries, the 3-dimensional notch volume was significantly smaller in knees with ACL tears than in intact-ACL control knees. Notch volume was also significantly smaller in girls than in boys and did not vary significantly with age. LEVEL OF EVIDENCE: Level III, case-control study.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament/pathology , Athletic Injuries/pathology , Knee Injuries/diagnosis , Knee Joint/pathology , Magnetic Resonance Imaging/methods , Adolescent , Case-Control Studies , Child , Female , Femur/growth & development , Femur/pathology , Humans , Imaging, Three-Dimensional , Knee Joint/growth & development , Male , Organ Size , Reproducibility of Results
4.
Am J Sports Med ; 41(6): 1319-29, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23576685

ABSTRACT

BACKGROUND: Current techniques of anterior cruciate ligament (ACL) reconstruction focus on the placement of femoral and tibial tunnels at anatomic ACL attachments, which can be difficult to identify intraoperatively. PURPOSE: To determine whether the 3-dimensional (3D) center of ACL attachments can be reliably detected from routine magnetic resonance imaging (MRI) in patients with intact ACLs and whether the reliability of this technique changes if the ACL is torn. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 3. METHODS: A computer technique was developed in which users identify points along ACL attachments on routine clinical MRI of preoperative knees. These attachments are then displayed on a 3D MRI reconstruction, which can be used as a visual guide for the surgeon during arthroscopic surgery. Thirty-seven pediatric patients (age range, 10-17 years) with ACL tears and 37 controls with intact ACLs were examined. Two blinded observers identified cruciate ligament attachments on routine clinical 1.5-T MRI of knees. From the resulting 3D model, the location of the center of each ligament attachment site and its area were calculated and reliability assessed. RESULTS: Mean interobserver variation of the centers of ACL attachments for the intact versus torn ACL was 1.7 ± 0.9 mm versus 1.8 ± 1.1 mm (femoral) and 1.4 ± 0.9 mm versus 1.7 ± 1.0 mm (tibial), respectively (P > .05). The 95% confidence interval for the center location was at most 4 mm. The identified ACL attachment areas were more variable, with interobserver reliability ranging from fair to excellent by the intraclass correlation coefficient. Overlap of ligament areas between observers for the intact versus torn ACL was 70% ± 15% versus 73% ± 12% (femoral) and 79% ± 9% versus 78% ± 10% (tibial), respectively (P > .05). In all cases, intraobserver reliability was superior to interobserver reliability. CONCLUSION: The 3D locations of ACL tibial and femoral attachment centers were identified from routine clinical MRI with variability averaging less than 2 mm between 2 observers. The margin of error was at most 4 mm, representing the thickness of a single axial MRI slice, whether the ACL was intact or torn. Remnant tissue at attachments allows a reliable assessment even of torn ligaments. Identification of the ligament attachment areas was more user dependent than was identification of the attachment centers.


Subject(s)
Anterior Cruciate Ligament Reconstruction , Anterior Cruciate Ligament/anatomy & histology , Magnetic Resonance Imaging , Software , Adolescent , Anterior Cruciate Ligament/surgery , Anterior Cruciate Ligament Injuries , Arthroscopy , Child , Female , Femur/anatomy & histology , Humans , Imaging, Three-Dimensional , Male , Observer Variation , Single-Blind Method , Tibia/anatomy & histology , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...