Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
Europace ; 25(2): 586-590, 2023 02 16.
Article in English | MEDLINE | ID: mdl-36575941

ABSTRACT

AIMS: Same-day discharge (SDD) is safe for patients undergoing electrophysiology procedures. There is no existing data regarding SDD for patients undergoing transvenous lead extraction (TLE). We report our experience with SDD for patients undergoing TLE. METHODS AND RESULTS: The study group included patients undergoing TLE between February 2020 and July 2021 without an infectious indication. A modified SDD protocol for device implants/ablations was applied to TLE patients. Patient characteristics, extraction details, outcomes, and complications were reviewed. Of 239 patients undergoing TLE, 210 were excluded (94 infections and 116 did not meet SDD criteria). Of the remaining 29 patients, seven stayed due to patient preference and 22 were discharged home the same day. The SDD group had an average age of 65.9 ± 12 (47-84), 41% female, and LVEF of 52.2 ± 18% (10-80). The indication for TLE was malfunction (20), upgrade (4), advisory lead (2), and magnetic resonance imaging compatibility (1). Extractions included four implantable cardioverter-defibrillators (ICDs), 17 pacemakers (PPM), and one cardiac resynchronization therapy (CRT)-P system. The leads were 9.6 years (1.5-21.7) old, and 1.8 leads were removed per patient (1-3); the lead extraction difficulty (LED) score was 11.6 ± 7. Twenty underwent cardiovascular implantable electronic device (CIED) re-implantation (2 ICD, 3 CRT-D, 13 PPM, and 2 CRT-P). For CIED re-implants, patients sent a remote transmission the next day, and all patients received a next-day call. There were no procedure or device-related issues, morbidities, or mortalities in the 30 days after discharge. CONCLUSION: Same-day discharge after TLE for non-infectious aetiologies is safe and feasible in a select group of patients with early procedure completion who meet strict SDD criteria.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Pacemaker, Artificial , Humans , Female , Middle Aged , Aged , Male , Patient Discharge , Feasibility Studies , Device Removal/adverse effects , Device Removal/methods , Defibrillators, Implantable/adverse effects , Retrospective Studies , Pacemaker, Artificial/adverse effects , Treatment Outcome
3.
Eur J Heart Fail ; 23(8): 1404-1415, 2021 08.
Article in English | MEDLINE | ID: mdl-33964186

ABSTRACT

AIMS: Infections are common following left ventricular assist device (LVAD) implantation and predict adverse events. Infections are frequent prior to LVAD implantation although their impact on postoperative outcomes remains unknown. Gut and nasal microbial imbalance may predispose to mucosal colonization with pathogens. Herein, we investigated the predictive role of pre-LVAD infections, and explored the association of nasal Staphylococcus aureus (SA) colonization and gut microbiota, on postoperative outcomes. METHODS AND RESULTS: Overall, 254 LVAD patients were retrospectively categorized based on pre-LVAD infection status: Group 1, bacterial/fungal bloodstream infection (BSI); Group 2, other bacterial/fungal; Group 3, viral; and Group 4, no infection. In a subset of patients, nasal SA colonization (n = 140) and pre-LVAD stool (n = 25) were analysed using 16S rRNA sequencing. A total of 75 (29%) patients had a pre-LVAD infection [Group 1: 22 (29%); Group 2: 41 (55%); Group 3: 12 (16%)]. Pre-LVAD BSIs were independent predictors of 1-year postoperative mortality and infections [Group 1 vs. 4: hazard ratio (HR) 2.70, P = 0.036 vs. HR 1.8, P = 0.046]. In an unadjusted analysis, pre-LVAD infections other than BSIs, INTERMACS profile ≤2, higher serum creatinine, lower serum albumin and nasal SA colonization were also significantly associated with postoperative infections. Patients with early post-LVAD infections exhibited decreased microbial diversity (P < 0.05). CONCLUSIONS: Pre-LVAD infections are common. BSIs independently predict postoperative mortality and infections. Additional studies are needed to confirm our findings that pre-LVAD SA nasal colonization and gut microbial composition can help stratify patients' risk for infectious complications after LVAD implantation.


Subject(s)
Gastrointestinal Microbiome , Heart Failure , Heart-Assist Devices , Humans , RNA, Ribosomal, 16S , Retrospective Studies , Staphylococcus aureus , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...