Eur J Radiol ; 177: 111557, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38954912

ABSTRACT

PURPOSE: When treating Lung Cancer, it is necessary to identify early treatment failure to enable timely therapeutic adjustments. The Aim of this study was to investigate whether changes in tumor diffusion during treatment with chemotherapy and bevacizumab could serve as a predictor of treatment failure. MATERIAL AND METHODS: A prospective single-arm, open-label, clinical trial was conducted between September 2014 and December 2020, enrolling patients with stage IV non-small cell lung cancer (NSCLC). The patients were treated with chemotherapy-antiangiogenic combination. Diffusion weighted magnetic resonance imaging (DW-MRI) was performed at baseline, two, four, and sixteen weeks after initiating treatment. The differences in apparent diffusion coefficient (ADC) values between pre- and post-treatment MRIs were recorded as Delta values (ΔADC). We assessed whether ΔADC could serve as a prognostic biomarker for overall survival (OS), with a five year follow up. RESULTS: 18 patients were included in the final analysis. Patients with a ΔADC value ≥ -3 demonstrated a significantly longer OS with an HR of 0.12 (95 % CI; 0.03- 0.61; p = 0.003) The median OS in patients with a ΔADC value ≥ -3 was 18 months, (95 % C.I; 7-46) compared to 7 months (95 % C.I; 5-9) in those with a ΔADC value < -3. CONCLUSION: Our findings suggest that early changes in tumor ADC values, may be indicative of a longer OS. Therefore, DW-MRI could serve as an early biomarker for assessing treatment response in patients receiving chemotherapy combined with antiangiogenic therapy.


Subject(s)
Angiogenesis Inhibitors , Bevacizumab , Carcinoma, Non-Small-Cell Lung , Diffusion Magnetic Resonance Imaging , Lung Neoplasms , Humans , Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Carcinoma, Non-Small-Cell Lung/drug therapy , Diffusion Magnetic Resonance Imaging/methods , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/drug therapy , Female , Male , Prospective Studies , Middle Aged , Aged , Prognosis , Bevacizumab/therapeutic use , Angiogenesis Inhibitors/therapeutic use , Neoplasm Staging , Antineoplastic Combined Chemotherapy Protocols/therapeutic use
2.
Eur J Radiol Open ; 5: 189-193, 2018.
Article in English | MEDLINE | ID: mdl-30450371

ABSTRACT

PURPOSE: The aim of this study was to compare respiratory-triggered (RT) and free breathing (FB) diffusion weighted imaging (DWI) techniques regarding apparent diffusion coefficient (ADC) measurements and repeatability in non-squamous non-small cell lung cancer (NSCLC) measuring the total tumor volume. MATERIAL AND METHODS: A total of 57 magnetic resonance imaging (MRI) examinations were analyzed. DWI was obtained by a single-shot spin-echo echo-planar imaging sequence, and for each MRI examination 2 consecutive RT and 2 consecutive FB DWI sequences were performed. Two radiologists independently read the images and made measurements. For each tumor the mean ADC value of the whole tumor volume was calculated. The difference in mean ADCs between FB and RT DWI was evaluated using the paired-sample t-test. The repeatability of ADC measurements related to imaging method was evaluated by intra class correlations (ICC) for each of the FB and RT DWI pairs. RESULTS: There were no significant differences in mean ADCs between FB and RT (Reader 1 p = 0.346, Reader 2 p = 0.583). The overall repeatability of ADC measurement was good for both acquisition methods, with ICCs > 0.9. Subgroup analysis showed somewhat poorer repeatability in small tumors (50 ml or less) and tumors in the lower lung zones for the RT acquisition, with ICC as low as 0.72. CONCLUSIONS: No difference in ADC measurement or repeatability between FB and RT DWI in whole lesion ADC measurements of adenocarcinomas in the lung was demonstrated. The results imply that in this setting the FB acquisition method is accurate and possibly more robust than the RT acquisition technique.

SELECTION OF CITATIONS
SEARCH DETAIL
...