Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Knee ; 48: 217-225, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38733872

ABSTRACT

BACKGROUND: Anterior knee pain (AKP) is one of the reasons for dissatisfaction after total knee replacement (TKR). It may result from patellofemoral joint dysfunction, caused by improper rotation of implant components. The aim of this study was to analyze patella positioning in patients after standard measured resection TKR and TKR with a use of a dynamic tensioner, and to assess the frequency of AKP, range of motion (ROM), and patient-reported outcome measures 6 weeks and 3 months postoperatively. METHODS: The study consisted of 127 patients who underwent TKR. Eighty-nine of them treated with use of the dynamic tensioner FUZION formed the study group; the remainder formed the control group. All participants received cemented PERSONA MC without patella resurfacing. All patients had a standard anteroposterior, lateral weight-bearing, long-leg view X-ray and computed tomography examination in 30° of knee flexion following the procedure. RESULTS: There were no significant differences between the study and the control groups regarding: posterior condylar axis (PCA)-patella angle, surgical transepicondylar axis (sTEA)-patella angle, PCA-sTEA angle, deviation from 90° in PCA-patella, sTEA-patella and PCA-sTEA angles. No significant difference was found in a ratio of obtaining PCA-patella angle deviation of more than 3°. Regarding clinical parameters, statistically and questionablly clinically significant difference in favor of the Study Group was found in Forgotten Joint Score 6 weeks and 3 months post-operativley and ROM 6 weeks post-operatively. However, such difference was not found by analyzing ROM 3 months post-operatively, AKP and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores. CONCLUSION: Compared with the standard 3° of femoral component external rotation, use of a dynamic tensioner does not allow for more accurate restoration of the patellar facet position with reference to the PCA.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Patella , Range of Motion, Articular , Humans , Arthroplasty, Replacement, Knee/methods , Male , Female , Case-Control Studies , Range of Motion, Articular/physiology , Aged , Patella/surgery , Middle Aged , Rotation , Osteoarthritis, Knee/surgery , Osteoarthritis, Knee/physiopathology , Femur/surgery , Prosthesis Design , Knee Joint/surgery , Knee Joint/physiopathology , Knee Joint/diagnostic imaging
2.
Medicina (Kaunas) ; 59(5)2023 May 04.
Article in English | MEDLINE | ID: mdl-37241112

ABSTRACT

Background and Objectives: Total knee arthroplasty (TKA) is the most effective treatment method for end-stage osteoarthritis. One of the most important aspects of this surgery is adequate implant positioning, as it guarantees the desired outcome of restoring limb biomechanics. Surgical technique is being continuously improved along with hardware development. There are two novel devices designed to help establish proper femoral component rotation: soft-tissue tensor and robotic-assisted TKA (RATKA). This study compared the femoral component rotation achieved with the use of three methods: RATKA, soft tissue tensioner and the conventional measured-resection technique, all of them utilizing anatomical design prosthesis components. Materials and Methods: A total of 139 patients diagnosed with end-stage osteoarthritis underwent total knee arthroplasty between December 2020 and June 2021. After the surgery, they were divided into three groups depending on procedure technique and implant type: Persona (Zimmer Biomet) + Fuzion Balancer, RATKA + Journey II BCS or conventional TKA + Persona/Journey. Postoperatively, a computed tomography examination was performed in order to measure femoral component rotation. All three groups were compared independently during statistical analysis. Fisher's exact, Kruskal-Wallis and Dwass-Steel-Crichtlow-Fligner tests were used for particular calculations. Results: Statistically significant differences in femoral component rotation between groups were noticed. However, in terms of values other than 0° in external rotation, no significant variance was revealed. Conclusions: Additional total knee arthroplasty instruments seem to improve the outcomes of the surgery, providing better component positioning than in the conventional measured-resection technique based only on bone landmarks.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Robotic Surgical Procedures , Humans , Knee Joint/surgery , Femur/surgery , Osteoarthritis, Knee/surgery , Prostheses and Implants
3.
Medicine (Baltimore) ; 101(42): e31107, 2022 Oct 21.
Article in English | MEDLINE | ID: mdl-36281192

ABSTRACT

In every surgical subspecialty surgical site infection (SSI) or implant infections, although occur seldom, pose a threat to patients' health. Risk factors of such states is diabetes mellitus (DM), considered one of the most widespread health-related problems of the 21st century. Orthopedists perform big joint replacements that usually concern older adults and therefore often deal with patients suffering from comorbidities. DM is frequently one of them and can furthermore often remain underdiagnosed. The other risk for complication is a rapid beginning of the rehabilitation which starts on the day following the surgery. To eliminate the debilitating impact of DM and hypoglycemia on surgical patients, we aim to investigate the relationship between the glycemia values and the postoperative outcomes in certain periods of time in patients undergoing orthopedic surgeries. Participants meeting inclusion criteria will have inserted a glycemia measuring device (Dexcom G5, Inc., San Diego, CA) in the periods of time. First time it will take place 14 days prior to the surgery and right after the surgery for the second time for the period of another 14 days. All patients will undergo standard total knee arthroplasty or total hip arthroplasty procedures. Patients will be assessed preoperatively and 14 days, 1, 3, 6, 12, and 24 months postoperatively. The assessment of the joint condition will consist of: patient-reported outcomes (The Knee injury and Osteoarthritis Outcome Score, Harris Hip Score, the Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC]); assessment of potential SSI and cardiovascular complications (the Finnish Diabetes Risk Score [FINDRISC], the Systematic Coronary Risk Evaluation [SCORE]) and the clinical examination. To investigate the influence of orthopedic surgery (anesthesia) on glycemia and the significance and safety of early patients mobilization after the big joints surgeries. To investigate changes of glycemia in patients with normal glycemia metabolism, potentially protecting them from hypoglycemia during hospital stay and increasing their awareness of potential development of DM in the future. Additionally, this study will correlate perioperative glycemic levels with risk of cardiovascular events in one year follow-up, and its influence on SSI and implant complications.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Hypoglycemia , Osteoarthritis , Aged , Humans , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Hypoglycemia/etiology , Observational Studies as Topic , Osteoarthritis/etiology , Postoperative Period , Surgical Wound Infection/etiology , Treatment Outcome
4.
Arthroplast Today ; 14: 29-35, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35128014

ABSTRACT

BACKGROUND: Total knee arthroplasty (TKA) is considered to be highly successful in treatment of end-stage osteoarthritis. There are multiple implant designs available on the market, and it is difficult to point which one is the best. The aim of this study was to compare the clinical and functional outcomes and gait pattern after TKA with the use of fixed-bearing medial pivot (K-Mod) vs multi-radius design (NexGen) implants and to compare them to norms for healthy patients with no osteoarthritis or arthroplasty procedure in anamnesis. METHODS: A group of 30 patients who received the medial pivot (MP) TKA and 33 patients who received the posterior-stabilized (PS) TKA between May and August of 2018 were included. All surgeries were performed in the level III academic hospital by a single surgeon. Every patient was asked to fulfill the The Western Ontario and McMaster Universities Arthritis Index (WOMAC) questionnaire preoperatively and 2 years postoperatively. Standard X-ray, biomechanical gait analysis using a motion capture system, and statistical analysis were performed at 2 years postoperatively. RESULTS: A total of 28 patients from either MP cohort (93%) or PS (85%) matched-control cohort completed the whole assessment at the final follow-up. There were statistically significant differences in a few gait parameters such as shorter mean step length both in operated and healthy limb, lower mean gait velocity, and lower mean walking cadence than the norm in both MP and PS groups. As to the WOMAC score, there was statistically significant improvement in both groups comparing preoperative and postoperative outcomes. Nevertheless, in the MP group, there was a significantly higher score, indicating worse outcomes, in the stiffness part of the WOMAC score than in the PS group. No significant differences were found between groups during radiological evaluation. CONCLUSIONS: There were satisfying and promising clinical, radiographic, and patient-reported outcomes in both MP and PS groups with very little difference in relation to norm values. However, both implants failed in fully restoring gait patterns similar to the healthy limb of the same patient.

5.
Arch Orthop Trauma Surg ; 142(12): 4015-4023, 2022 Dec.
Article in English | MEDLINE | ID: mdl-34837506

ABSTRACT

INTRODUCTION: Total hip replacement (THR) is considered one of the most effective medical procedures in treatment of osteoarthritis. Since its introduction, there has been a worldwide debate over proper implant selection in terms of size, bearing type and shape. Following study was designed to assess the importance of femoral head size in long-term follow-up. MATERIALS AND METHODS: A cohort of 30 patients with primary end stage osteoarthritis who underwent total hip replacement was analysed retrospectively. A homogenous group was chosen with no major differences in BMI. Patients' gait parameters were measured in a biomechanics laboratory using the 3D BTS Smart system. WOMAC and VAS questionnaires were used to assess patient reported outcome. RESULTS: The subgroup with larger implant head size had several outcomes significantly superior to the subgroup with standard head size and non-inferior to healthy hips. Following variables were measured during this study: time of support phase, time of swing phase, double support time, walking hip extension angle. CONCLUSIONS: Use of larger sized femoral heads during THR gives better results in terms of gait pattern. Since restoring the gait pattern is one of the aspects of rehabilitation and returning to daily activities it seems to be an important observation.


Subject(s)
Arthroplasty, Replacement, Hip , Osteoarthritis , Humans , Arthroplasty, Replacement, Hip/methods , Femur Head/surgery , Retrospective Studies , Cohort Studies , Gait , Osteoarthritis/surgery , Hip Joint/surgery
6.
Arthroplast Today ; 12: 62-67, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34765714

ABSTRACT

BACKGROUND: Total knee arthroplasty (TKA) is considered the most efficient treatment of end-stage osteoarthritis. There is an ongoing debate about proper implant designs and articulation types. One of the considered causes of unsatisfactory outcome and patients' dissatisfaction is femoral or tibial component overhanging, which can lead to chronic knee pain and restricted motion. The aim of this study is to compare radiological outcomes of TKA using an anatomic PERSONA Posterior-Stabilized (PS) knee design with its nonanatomic predecessor, the NexGen LPS. METHODS: A group of 39 patients who received the PERSONA PS system and 33 patients who received the NexGen LPS was included. PERSONA patients were matched to NexGen patients using a 0.1 propensity score threshold with priority given to exact matches. Anteroposterior, lateral, and long-leg radiographs were taken preoperatively and at 6 weeks postoperatively to perform radiological and statistical analysis. RESULTS: The PERSONA subgroup had statistically higher posterior condylar offset. There is no statistically significant difference in posterior condylar offset ratio. There were less cases of femoral notching, femoral overhang, and placing tibial baseplate in the medial overhang in the PERSONA PS subgroup than in the NexGen subgroup (each statistically significant). Occurrence of tibial underhang was not statistically significant. CONCLUSION: Radiological assessment in short-term follow-up showed excellent results for PERSONA knee design with better fit to native femur and tibia. In comparison to its predecessor, it also spares more bone tissue. As the aforementioned parameters are risk factors of lesser clinical outcomes, the PERSONA design gives high hopes for improvement of TKA satisfaction rate.

7.
BMC Endocr Disord ; 21(1): 143, 2021 Jul 03.
Article in English | MEDLINE | ID: mdl-34217288

ABSTRACT

BACKGROUND: Type 2 diabetes (T2D) is a cause of multiple complications, including retinopathy and peripheral neuropathy. These complications are well understood and believed to contribute to gait instability. Poor balance control and increased falling risk have also been reported in people with diabetic peripheral neuropathy (DPN). Patients with DPN have increased risk of falling due to decreased proprioceptive feedback. Effective balance training should improve postural control in patients with DPN. For this purpose further evaluation was conducted and balance training was designed. METHODS: The goal of our study was to determine values of proprioception, balance, muscle coordination and strength in patients with T2D and analyze whether biofeedback balance training with use of the Biodex Balance System could improve these parameters. To assess the fall risk the general stability index (GSI), the index of frontal-posterior (FPI) and medial-lateral (MLI) stability were evaluated. 37 patients with diagnosed type 2 diabetes mellitus were recruited to this study. Their results were compared with control group consisting of 41 healthy participants who were homogenic to the study group in terms of age and body mass index (BMI). RESULTS: There were statistically significant differences between patients with diabetes compared to healthy subjects in GSI (2.79 vs 1.1), FPI (1.66 vs 0.7), MLI (0.88 vs 0.52) and risk of falling (5.18 vs 2.72) p < 0.05. There were also statistically significant changes before and after training in all stability indices (GSI: 2.79 vs 1.26, FPI: 1.66 vs 0.77, MLI: 0.88 vs 0.54 accordingly) p < 0.05 and risk of falling (5.18 vs 3.87) p < 0.05 in the study group who had undergone training with biofeedback. CONCLUSIONS: This study found that there is a decreased balance and motor coordination and an increased risk of falling in patients with type 2 diabetes. These parameters improved in patients who have undergone training programme with biofeedback. Furthermore, an age-dependent deprivation of static balance was observed along with an increased risk of falling as a result of increasing BMI.


Subject(s)
Diabetes Mellitus, Type 2/complications , Diabetic Neuropathies/complications , Diabetic Neuropathies/therapy , Exercise Therapy/methods , Gait Disorders, Neurologic/rehabilitation , Postural Balance , Proprioception , Accidental Falls , Aged , Aged, 80 and over , Body Mass Index , Female , Gait Disorders, Neurologic/physiopathology , Humans , Male , Muscle Strength , Non-Randomized Controlled Trials as Topic
8.
J Clin Med ; 10(11)2021 May 21.
Article in English | MEDLINE | ID: mdl-34064295

ABSTRACT

Total hip arthroplasty (THA) is currently considered the most effective treatment for end-stage hip osteoarthritis (OA). The surgery can be performed via a number of different approaches, including direct anterior (DAA; Smith-Petersen; Hueter), anterolateral (ALA; Watson-Jones), direct lateral (LA; Bauer), posterior (PA; Kocher-Langenbeck), and posterolateral (PLA). There is still a dispute over the optimal technique. The aim of this systematic review was to assess how different surgical approaches toward a THA influence the prosthesis elements' positioning. We conducted a literature search of Scopus, ScienceDirect, PubMed, Embase, and The Cochrane Library. We evaluated studies in terms of the first author's name, country, publication year, type of surgical approach being compared to the direct anterior approach, any significant differences at baseline, sample size, and radiographic analysis. A subanalysis of each approach in comparison to the DAA revealed differences in terms of all analyzed implant positioning radiographic parameters. There is still an insufficient number of randomized controlled studies that include radiological analyses comparing THRs (total hip replacements) performed using DAA with other approaches. Implant placement is a crucial step during a THR and surgeons must be aware that the approach they use might impact their judgment on angles and spaces inside the joint and thus alter the implant positioning.

SELECTION OF CITATIONS
SEARCH DETAIL
...