1.
J Appl Crystallogr ; 57(Pt 3): 690-699, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38846768

ABSTRACT

Scintillator-based ZnS:Ag/6LiF neutron detectors have been under development at ISIS for more than three decades. Continuous research and development aim to improve detector capabilities, achieve better performance and meet the increasingly demanding requirements set by neutron instruments. As part of this program, a high-efficiency 2D position-sensitive scintillator detector with wavelength-shifting fibres has been developed for neutron-diffraction applications. The detector consists of a double scintillator-fibre layer to improve detection efficiency. Each layer is made up of two orthogonal fibre planes placed between two ZnS:Ag/6LiF scintillator screens. Thin reflective foils are attached to the front and back scintillators of each layer to minimize light cross-talk between layers. The detector has an active area of 192 × 192 mm with a square pixel size of 3 × 3 mm. As part of the development process of the double-layer detector, a single-layer detector was built, together with a prototype detector in which the two layers of the detector could be read out separately. Efficiency calculations and measurements of all three detectors are discussed. The novel double-layer detector has been installed and tested on the SXD diffractometer at ISIS. The detector performance is compared with the current scintillator detectors employed on SXD by studying reference crystal samples. More than a factor of 3 improvement in efficiency is achieved with the double-layer wavelength-shifting-fibre detector. Software routines for further optimizations in spatial resolution and uniformity of response have been implemented and tested for 2D detectors. The methods and results are discussed in this manuscript.

2.
Radiat Prot Dosimetry ; 126(1-4): 278-83, 2007.
Article in English | MEDLINE | ID: mdl-17522030

ABSTRACT

The latest advances in the development of a fluorescent nuclear track detector (FNTD) for neutron and heavy charged particle dosimetry are described and compared with CR-39 plastic nuclear etched track detectors (PNTDs). The technique combines a new luminescent aluminium oxide single crystal detector (Al(2)O(3):C,Mg) with an imaging technique based on laser scanning and confocal fluorescence detection. Detection efficiency was obtained after irradiations with monoenergetic neutron and proton beams. Dose dependences were measured for different configurations of the detectors exposed in fast- and thermal-neutron fields. A specially developed image processing technique allows for fast fluorescent track identification and counting. The readout method is non-destructive, and detectors can be reused after thermal annealing.


Subject(s)
Aluminum Oxide/radiation effects , Linear Energy Transfer , Neutrons , Optics and Photonics/instrumentation , Radiation Monitoring/instrumentation , Radiation Protection/instrumentation , Spectrometry, Fluorescence/instrumentation , Thermoluminescent Dosimetry/instrumentation , Equipment Design , Equipment Failure Analysis , Radiation Dosage , Radiation Monitoring/methods , Radiation Protection/methods , Reproducibility of Results , Sensitivity and Specificity , Spectrometry, Fluorescence/methods , Thermoluminescent Dosimetry/methods