Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Chem Chem Phys ; 8(2): 293-302, 2006 Jan 14.
Article in English | MEDLINE | ID: mdl-16482272

ABSTRACT

We demonstrate that broad-band cavity enhanced Raman scattering (CERS) can be used to determine the composition of binary alcohol-water aerosol droplets over a wide compositional range from 10% v/v to 90% v/v. In contrast to conventional CERS using narrow-band laser excitation, the excitation is provided by a broad-band Nd:YAG pumped dye laser. A change in the spontaneous spectrum resulting from the change of the linewidth of the excitation laser permits tuning of the sensitivity range over which the droplet composition can be determined by CERS. We demonstrate that this change in sensitivity can be estimated using a simulation of the change in the sensitivity to the species in spontaneous bulk phase measurements. We further show that the compositional calibration is independent of droplet radius in the range 33-56 microm. The compositional range over which CERS is sensitive can be controlled and optimised for any particular application by exploiting the dependence of the stimulated Raman scattering on the laser linewidth and wavelength. Thus, quantitative measurements of droplet composition can be made in situ with high accuracy, providing a valuable new tool for analysing aerosol composition.


Subject(s)
Aerosols/chemistry , Alcohols/chemistry , Spectrum Analysis, Raman/methods , Water/chemistry , Calibration , Particle Size
2.
Phys Chem Chem Phys ; 7(7): 1414-22, 2005 Apr 07.
Article in English | MEDLINE | ID: mdl-19787963

ABSTRACT

Stimulated Raman scattering (SRS) from single aerosol droplets can be observed at extremely low laser threshold intensities at wavelengths commensurate with whispering gallery modes. Although droplet size can routinely be determined from the ensuing cavity enhanced Raman scattering (CERS) fingerprint, determining droplet composition is a considerably more challenging measurement. We present here an examination of the factors that influence and limit the detection sensitivity of CERS in quantifying the concentrations of sulfate and nitrate in water droplets, 20-50 microm in radius. In particular, we consider the variation in nitrate and sulfate SRS signal with variation in species concentration, probe laser intensity and droplet size. We illustrate that the band contour of the OH stretching band can be used as a relative measure of the internal light intensity circulating within the droplet and experimentally investigate how the threshold condition for SRS is achieved.

SELECTION OF CITATIONS
SEARCH DETAIL
...