1.
Phys Med Biol ; 60(4): 1681-96, 2015 Feb 21.
Article in English | MEDLINE | ID: mdl-25633183

ABSTRACT

A commercial active breathing coordinator (ABC) device, employed to hold respiration at a specific level for a predefined duration, was successfully adapted for magnetic resonance imaging (MRI) use for the first time. Potential effects of the necessary modifications were assessed and taken into account. Automatic MR acquisition during ABC breath holding was achieved. The feasibility of MR-ABC thoracic and abdominal examinations together with the advantages of imaging in repeated ABC-controlled breath holds were demonstrated on healthy volunteers. Five lung cancer patients were imaged under MR-ABC, visually confirming the very good intra-session reproducibility of organ position in images acquired with the same patient positioning as used for computed tomography (CT). Using identical ABC settings, good MR-CT inter-modality registration was achieved. This demonstrates the value of ABC, since application of T1, T2 and diffusion weighted MR sequences provides a wider range of contrast mechanisms and additional diagnostic information compared to CT, thus improving radiotherapy treatment planning and assessment.


Subject(s)
Breath Holding , Magnetic Resonance Imaging/methods , Respiratory-Gated Imaging Techniques/methods , Humans , Magnetic Resonance Imaging/instrumentation , Male , Patient Positioning , Respiratory-Gated Imaging Techniques/instrumentation , Transducers
2.
Phys Med Biol ; 51(9): 2225-36, 2006 May 07.
Article in English | MEDLINE | ID: mdl-16625038

ABSTRACT

The fundamentals of IMRT collimation have been studied using ten conceptual collimators. Spanning a range of complexities from the LINAC jaws alone to a full multi-leaf collimator (MLC), these collimators were designed with two abilities in mind: (1) to be able to define arbitrary field shapes, and (2) to be able to irradiate multiple, disconnected regions in a single segment. The collimators were tested by finding decompositions of random and clinical intensity-modulated beams (IMBs), and collimator performance was measured using both the number of segments required to complete the IMB and the monitor-unit efficiency of the treatment. The decompositions were run on 10 x 10 IMBs with integer bixel values randomly between 1 and 10, and clinical IMBs of varying sizes from lung, head and neck, and pelvic patients taken from a Pinnacle treatment-planning system. Results confirmed that although treatment performance improves with increased collimator complexity, it is not solely dependent on the number of segment shapes deliverable by the collimator but instead on how well these shapes lend themselves to IMRT delivery.


Subject(s)
Models, Theoretical , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/instrumentation , Computer Simulation , Equipment Design , Equipment Failure Analysis , Radiotherapy Dosage , Radiotherapy, Conformal/methods
3.
Phys Med Biol ; 51(7): 1725-36, 2006 Apr 07.
Article in English | MEDLINE | ID: mdl-16552100

ABSTRACT

The potential of the variable-aperture collimator (VAC) in intensity-modulated radiation therapy (IMRT) has been evaluated by comparing its performance with that of the multi-leaf collimator (MLC). This comparison used a decomposition algorithm to find the series of collimator segments that would treat a given intensity-modulated beam (IMB). Collimator performance was measured using both the number of segments required to complete the IMB and the monitor-unit efficiency of the treatment. The VAC was modelled with aperture sizes from 4 x 4 cm to 20 x 20 cm, and these apertures were allowed to be located anywhere within the IMB. To enable a direct comparison, a similar scanning MLC was modelled at the same range of aperture sizes. Using both collimators, decompositions were run on 10 x 10 and 20 x 20 random IMBs with integer bixel values ranging from 1 to 10. Clinical IMBs from lung, head and neck, and pelvic patients were taken from a Pinnacle treatment-planning system and tested in the same manner. It was found that for all treatment sites, a small, scanning MLC performs as well or better than an equivalent sized VAC in both number of segments and monitor-unit efficiency, and would be an efficient choice for centres looking for a simple collimator for IMRT.


Subject(s)
Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Algorithms , Humans , Radiotherapy Planning, Computer-Assisted/instrumentation
4.
Phys Med Biol ; 45(11): 3159-70, 2000 Nov.
Article in English | MEDLINE | ID: mdl-11098896

ABSTRACT

In some linear accelerators, the charge collected by the monitor ion chamber is partly caused by backscattered particles from accelerator components downstream from the chamber. This influences the output of the accelerator and also has to be taken into account when output factors are derived from Monte Carlo simulations. In this work, the contribution of backscattered particles to the monitor ion chamber response of a Varian 2100C linac was determined for photon beams (6, 10 MV) and for electron beams (6, 12, 20 MeV). The experimental procedure consisted of charge integration from the target in a photon beam or from the monitor ion chamber in electron beams. The Monte Carlo code EGS4/BEAM was used to study the contribution of backscattered particles to the dose deposited in the monitor ion chamber. Both measurements and simulations showed a linear increase in backscatter fraction with decreasing field size for photon and electron beams. For 6 MV and 10 MV photon beams, a 2-3% increase in backscatter was obtained for a 0.5 x 0.5 cm2 field compared to a 40 x 40 cm2 field. The results for the 6 MV beam were slightly higher than for the 10 MV beam. For electron beams (6, 12, 20 MeV), an increase of similar magnitude was obtained from measurements and simulations for 6 MeV electrons. For higher energy electron beams a smaller increase in backscatter fraction was found. The problem is of less importance for electron beams since large variations of field size for a single electron energy usually do not occur.


Subject(s)
Electrons , Monte Carlo Method , Particle Accelerators/instrumentation , Photons , Scattering, Radiation