Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Oral Sci ; 66(2): 107-110, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38403676

ABSTRACT

PURPOSE: To investigate the elemental composition, corrosion resistance, and mechanical properties of computer-aided design and computer-aided manufacturing (CAD-CAM) retainers versus conventional fixed retainers (FRs). METHODS: Eight different retainer wires were investigated. Energy dispersive X-ray spectroscopy was used to determine the elemental composition. Leakage was analysed according to ISO 10271:2020 guidelines. Hardness was tested using the Vickers method with a load of 0.3 kg. The tensile force and tensile strength were evaluated. Multiple comparisons among wires of hardness, tensile force, and strength were conducted using the Welch t-test, with Bonferroni correction. RESULTS: Nickel was present in all wires. The CAD-CAM-FR wire, which contained more nickel than the other wires, had no measurable leakage. The gold-plated wires had the highest total leakage, but did not exceed the ISO standard limit. The hardness of the stainless-steel twisted wires was the highest and that of the CAD-CAM-FR wire was the lowest. The tensile strength of the CAD-CAM-FR wire was significantly lower than that of the other wires and similar to the other twisted-wire retainers. CONCLUSION: The CAD-CAM-FR wire is likely to have high corrosion resistance and flexibility due to its low hardness.


Subject(s)
Nickel , Orthodontic Retainers , Corrosion , Nickel/chemistry , Orthodontic Wires , Orthodontic Appliances, Fixed , Computer-Aided Design
2.
J Prosthet Dent ; 130(2): 255.e1-255.e10, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37355405

ABSTRACT

STATEMENT OF PROBLEM: Cobalt chromium (Co-Cr) alloys possess beneficial mechanical properties because alloys, even in thin sections, can resist high mastication forces and exhibit an acceptable bond to the surface porcelain layer. Traditional manufacturing techniques of Co-Cr alloys such as casting have been replaced with newer fabrication techniques, such as milling, laser melting, and presintered milling. Despite scarce documentation, these new manufacturing techniques are being used to fabricate dental and implant constructions. PURPOSE: This in vitro study investigates the hardness, yield strength, elastic modulus, and microstructure of the most commonly used Co-Cr alloys for fixed prosthodontics based on manufacturing technique. In addition, this study investigates the effect of heat treatment on the mechanical properties and microstructure of these materials. MATERIAL AND METHODS: Five Co-Cr alloys were included (dumbbell and rectangular shaped) based on four manufacturing techniques: cast, milled, laser melted, and presintered milled. Commercially pure titanium grade 4 and titanium-6 aluminum-4 vanadium ELI (extra low interstitial) were included for comparison, and yield strength and elongation after fracture were evaluated. The specimens were tested for hardness using the Vickers test and for elastic modulus using a nondestructive impulse excitation technique. The microstructure of selected specimens was analyzed using focused ion beam-scanning electron microscopy (FIB-SEM) and energy dispersive X-ray spectroscopy (EDS). RESULTS: The mechanical properties depend on the manufacturing technique used; the laser-melted and presintered Co-Cr specimens demonstrated the highest mechanical properties, followed by the milled and cast groups. Both the laser-melted and the presintered milled Co-Cr specimens showed smaller grain size compared with the cast and milled Co-Cr specimens. The titanium-6 aluminum-4 vanadium ELI demonstrated higher hardness and yield strength compared to commercially pure titanium grade 4. No major differences were observed for the selected materials regarding the mechanical properties and microstructural appearance after heat treatment. CONCLUSIONS: The laser melting and presintered milling techniques produced higher mechanical properties compared with the cast and milled Co-Cr. These findings were confirmed through microstructural analysis with respect to the grain size, precipitation, and number of pores.


Subject(s)
Chromium Alloys , Titanium , Chromium Alloys/chemistry , Aluminum , Prosthodontics , Vanadium , Alloys , Surface Properties , Materials Testing , Cobalt/chemistry , Metal Ceramic Alloys/chemistry , Chromium
3.
Biomater Investig Dent ; 10(1): 2191634, 2023.
Article in English | MEDLINE | ID: mdl-37090483

ABSTRACT

For individuals with very high to extremely high caries activity and poor control of daily oral hygiene, a simple treatment for arresting their caries activity is necessary. Silver Diamine Fluoride (SDF) has become increasingly common for this purpose due to its efficacy and ease of application. To avoid or reduce tooth discoloration after SDF treatment potassium iodide (KI) may be applied. However, the release of silver from SDF-treated tooth surfaces may be of concern. Thus, the aim of the present study was to quantify the amount of silver leached in both a short- and long-term perspective. In this in vitro experiment we measured the cumulative release of silver from SDF-treated dentin surfaces with and without imminent application of KI, and with and without phosphoric acid etching as pre-treatment, after 24 h and weekly for four weeks. The release of silver was highest after 24 h for all treatment groups, with a significant drop after this point. When etching was not used, the use of KI did not affect the release of silver. However, when etching was used, there was a significantly lower silver release when KI was also used compared to when KI was not used. This effect was largest for the first two weeks, after which the difference was smaller as all groups released low amounts of silver.

4.
Eur J Oral Sci ; 128(5): 444-449, 2020 10.
Article in English | MEDLINE | ID: mdl-32805064

ABSTRACT

The aims of the study were to investigate functional and esthetic properties, the composition of the alloy, and the content of hazardous elements of single dental crowns with metal skeleton and fired porcelain. Epoxy models made from full mouth impressions taken of a patient with a crown preparation of the right maxillary first permanent molar were used for production of identical polyether impressions, which were distributed to dentists in Norway. The dentists sent the impressions to their regular dental laboratories. All 55 crowns collected were anonymized and examined. Of the crowns received, 35 were made in Norway, 12 were imported, and 8 were of unknown origin. The evaluation of functional properties revealed that 50% of the Norwegian, 42% of the imported, and 25% of the unknown-origin crowns were considered unacceptable. The composition of the alloy was not in accordance with that stated by the manufacturer for 17%, 13% and 20% of the crowns, where this information was provided. The lead content of the alloy exceeded the limit set by the ISO 22674: 2016 for 18% of the crowns in total. The statement that shall follow the work according to EU-regulations was not complete for approximately 75% of the works received.


Subject(s)
Crowns , Metal Ceramic Alloys , Dental Porcelain , Dental Prosthesis Design , Humans , Molar , Norway
5.
Biomater Investig Dent ; 7(1): 71-79, 2020.
Article in English | MEDLINE | ID: mdl-32490402

ABSTRACT

Objective: The aims of this in vitro study were to assess if dynamic loading increases the metal ion release of selected dental alloys and to evaluate the cytotoxicity of the released metal ions. Materials and methods: One Pd-Ag alloy (Aurolite 2B) and two Co-Cr alloys (Wirobond 280 and d.Sign 30) were investigated. Two different corrosion immersion tests were used: a standardized static test (ISO 22674: 2016) and an experimental dynamic test. Both tests involved immersion of the specimens in a lactic acidic solution (pH = 2.3). Inductively coupled plasma mass spectrometry was used to identify and quantify released elements. A human monocyte cell-line (THP-1) was exposed to serially diluted solutions containing the selected metal ions. Cell viability was measured using the methyl-thiazolyl-tetrazolium assay. Results: According to the threshold defined in ISO 22674, only low concentrations of released elements were observed for both corrosion tests. No increase in metal ion release from the dynamic test compared with the static test was observed. Of the released elements, only Zn(II) and Co(II) showed a cytotoxic effect on THP-1 cells at 250 µM and higher concentrations. No increased viability loss was observed when adding other released elements to the exposure mixture. Conclusions: The tested alloys showed low levels of metal ion release from both static and dynamic corrosion testing. Dynamic loading did not increase the metal ion release compared to the static corrosion test. Concentrations of 250 µM and above of Zn(II) and Co(II) showed a cytotoxic effect on THP-1 cells.

6.
Eur J Orthod ; 27(5): 477-83, 2005 Oct.
Article in English | MEDLINE | ID: mdl-16043469

ABSTRACT

The shear bond strength (SBS) of a light-cured, resin-reinforced glass ionomer and a composite adhesive in combination with a self-etching primer was compared after different setting times to evaluate when orthodontic wires could be placed. Additionally, the fracture site after debonding was assessed using the Adhesive Remnant Index (ARI). Eighty freshly extracted human premolars were used. Twenty teeth were randomly assigned to each of four groups: (1) brackets bonded with Transbond XT with a Transbond Plus etching primer and debonded within 5 minutes; (2) brackets bonded with Fuji Ortho LC and debonded within 5 minutes; (3) brackets bonded as for group 1 and debonded within 15 minutes; (4) brackets bonded as for group 2 and debonded within 15 minutes. The SBS of each sample was determined with an Instron machine. The mean SBS were, respectively: (1) 8.8 +/- 2 MPa; (2) 6.6 +/- 2.5 MPa; (3) 11 +/- 1.6 MPa and (4) 9.6 +/- 1.6 MPa. Interpolating the cumulative fracture probability by means of a Weibull analysis, the 10 per cent probabilities of fracture for the groups were found to be attained for shear stresses of 6.1, 3.1, 8.3 and 7.1 MPa, respectively. Chi-square testing of the ARI scores revealed that the nature of the remnant did not vary significantly with time, but the type of bonding material could generally be distinguished in leaving more or less than 10 per cent of bonding material on the tooth. After debonding, the Transbond system was likely to leave adhesive on at least 10 per cent of the bonded area of the tooth. The present findings indicate that brackets bonded with either Transbond XT in combination with Transbond Plus etching primer and Fuji Ortho LC had adequate bond strength at 5 minutes and were even stronger 15 minutes after initial bonding.


Subject(s)
Dental Bonding/methods , Glass Ionomer Cements , Orthodontic Brackets , Resin Cements , Acrylic Resins , Aluminum Silicates , Bicuspid , Chi-Square Distribution , Dental Stress Analysis , Humans , Materials Testing , Random Allocation , Shear Strength , Statistics, Nonparametric , Survival Analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...