Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 23(7)2023 Mar 30.
Article in English | MEDLINE | ID: mdl-37050657

ABSTRACT

The passive multipliers based on semiconductor diodes, most frequently a Schottky type, should be driven by a certain value of input power, where the conversion losses are optimal. This means that the variation in the input power level causes the change in the output power level. A solution to this issue is the integration of an output power amplifier, which in the state of saturation provides quasi-stabilization of the output power. Practically, this approach gives an unsatisfactory performance: weak stabilization or narrow input power range. This paper comprises a concept of an active frequency multiplier with the use of one FET transistor and a special adaptive bias circuit in order to obtain a very wide input power range when the output power is stable. The principle of the operation, design guidelines, and measurement results have been presented for an example circuit of the frequency doubler. The results show the possibility to obtain up to 10 dB input power range for a 1 dB change in output power level without the use of additional amplifiers.

2.
Sensors (Basel) ; 22(10)2022 May 10.
Article in English | MEDLINE | ID: mdl-35632030

ABSTRACT

The article concerns the issue of non-invasive moisture sensing in building materials. Two techniques that enable evaluating the value of the relative permittivity of the material, being the measure of porous material moisture, have been utilized for the research. The first is the microwave technique that utilizes the non-contact measurement of velocity of microwave radiation across the tested material and the second is the time domain reflectometry (TDR) technique based on the measurement of electromagnetic pulse propagation time along the waveguides, being the elements of sensor design. The tested building material involved samples of red ceramic brick that differed in moisture, ranging between 0% and 14% moisture by weight. The main goal of the research was to present the measuring potential of both techniques for moisture evaluation as well as emphasize the advantages and disadvantages of each method. Within the research, it was stated that both methods provide similar measuring potential, with a slight advantage in favor of a microwave non-contact sensor over surface TDR sensor designs.


Subject(s)
Construction Materials , Microwaves , Porosity
3.
Sensors (Basel) ; 19(22)2019 Nov 06.
Article in English | MEDLINE | ID: mdl-31698878

ABSTRACT

Delay lines with a tunable length are used in a number of applications in the field of microwave techniques. The digitally-controlled analogue wideband delay line is particularly useful in noise radar applications as a precise detector of movement. In order to perform coherent reception in the noise radar, a delay line with a variable delay value is required. To address this issue, this paper comprises a new concept of a digitally-controlled delay line with a set of fine distance gates. In the paper, a solution for micro-movement detection is proposed, which is based on direct signal processing in the time domain with the use of a microwave analogue correlator. This concept assumes the use of a microwave analogue tapped delay line structure. It was found that the optimal solution for a noise radar with an analogue signal correlator is a combined delay line consisting of switched reference sections, a tapped delay line, and a precision phase shifter. The combined delay line presented in this paper is dedicated to serving as the adjustable reference delay for a noise radar intended for the detection of micro-movement. The paper contains the calculation results and delay line implementation for a given example. The new structure of the analogue tapped delay line with the calculation of optimal parameters is also presented. The precise detector of movement can be successfully used for the remote sensing of human vital signs (especially through-the-wall), e.g., breathing and heart beating, with the simultaneous determination of position.

SELECTION OF CITATIONS
SEARCH DETAIL
...