Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
Add more filters










Publication year range
1.
J Mech Behav Biomed Mater ; 152: 106450, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38325167

ABSTRACT

The aim of this study was to evaluate a novel approach for measuring the polymerization shrinkage of dental resin composites - measurement of sample depth variation. This new method was compared with two testing methodologies used for assessing the polymerization shrinkage (buoyancy and strain gauge methods). Eleven commercial resin composites were investigated (EverX Posterior; EverX Flow Bulk & Dentin; G-aenial Anterior, Posterior, A'chord & Universal Injectable; Filtek One Bulk Fill & Universal Restorative; SDR + Flow and Aura Bulk Fill). In addition, filler content (wt. %), flexural modulus, and the degree of conversion were evaluated. Shrinkage values, obtained by the buoyancy method, are greater than shrinkage evaluated by the strain gauge. There are significant differences in polymerization shrinkage among the tested resin composite materials. There is a strong correlation between the newly proposed method of shrinkage measurement and the buoyancy method (r2 = 0.8; p < 0.01). There is no correlation between volumetric shrinkage measurement (depth changes and buoyancy method) and linear strain measurement. Volumetric filler amount correlates with shrinkage values evaluated by all three methods. The degree of conversion for the tested resin composites ranges from 36 % to 52 %. There are some differences (around 10 %) between the filler content (wt. %) measured by the ashing-in-air method and the data given by the manufacturers. The highest flexural modulus is 14.8 GPa and the lowest 6.6 GPa. New formulations may introduce unknown relationships between the fundamental properties of dental resin composites.


Subject(s)
Gastropoda , Animals , Polymerization
2.
Dent Mater J ; 43(2): 155-163, 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38296513

ABSTRACT

The aim of this study was to compare two testing methodologies employed for assessing the polymerization shrinkage stress of dental resin composites. Ten commercial resin composites were investigated (EverX Posterior & Flow; G-ænial Anterior, Posterior, A'CHORD & Universal Injectable; Filtek One Bulk Fill & Universal Restorative; SDR flow+ and Aura Bulk Fill). Photoelastic and contraction forces measurement methods were performed. The slope of the linear trendline and C-factor of specimens were calculated. The shrinkage stress values (range between: 6.4-13.4 MPa) obtained by the photoelastic method were higher for all resin composites than the values obtained by contraction forces measurements (range between 1.2-4.8 MPa). However, there was a strong linear correlation between these methods (r=0.8). The use of both investigated methods revealed important information about the shrinkage behavior of the restorative resin composites.


Subject(s)
Composite Resins , Dental Materials , Polymerization , Dental Stress Analysis , Materials Testing
3.
J Funct Biomater ; 14(10)2023 Sep 22.
Article in English | MEDLINE | ID: mdl-37888152

ABSTRACT

Direct restorations are currently the most popular restorations used in dental prosthodontics. Due to the increased requirements for materials used in the fabrication of fixed restorations, there is a need for evaluation of strength parameters of these materials, including dental cements. The present study investigated the change in selected strength parameters of four dual-cured composite cements as a function of storage temperature. The following were investigated: three-point flexural strength (FS), flexural modulus in bending (FM), diametral tensile strength (DTS) and Vickers hardness (HV). Four dual-cured composite cements were tested, i.e., Multilink Automix (Ivoclar Vivadent), seT PP (SDI), MaxCem (Kerr), and Bifix Hybrid Abutment (VOCO). Each of the tested cements was stored for 7 days at one of the selected temperatures: 8 °C, 15 °C, 25 °C, or 35 °C, before the samples were made. Strength properties (DTS, FS) are not strongly dependent on the storage temperature in the range of 8-35 °C. Some statistical differences were observed between the hardness of MaxCem and Multilink Automix storage in various temperatures. FS and FM were lowest for Bifix Hybrid Abutment, MaxCem and Multilink Automix storage at 25 °C, and highest for Bifix Hybrid Abutment, MaxCem, and seT PP stored in 35 °C. The cement with the highest filler content (70% by weight) showed the highest FS and HV.

4.
Materials (Basel) ; 16(15)2023 Aug 02.
Article in English | MEDLINE | ID: mdl-37570137

ABSTRACT

Due to its unique properties, zirconia is increasingly being used in dentistry, but surface preparation for bonding is difficult because of its polycrystalline structure. This study aimed to determine the effect of a new etching technique (Zircos-E) on Ceramill Zi (Amann Girrbach). The effect of etching and the use of primers (Monobond Plus and MKZ Primer) on the bond strength of zirconia with resin cement (NX3) was assessed. Shear bond strength was evaluated after storage in water for 24 h and after thermal aging (5000 thermocycling at 5 °C/55 °C). A scanning electron microscope (Hitachi S-4700) was used to evaluate the surface structure before and after the Zircos-E system. The roughness parameters were assessed using an SJ-410 profilometer. The etched zirconia surface is more homogeneous over the entire surface, but some localized forms of erosion exist. The etching of zirconia ceramics caused changes in the surface structure of zirconia and a significant increase in the shear bond strength between zirconia and resin cement. The use of primers positively affects the adhesion between resin cement and zirconia. Aging with thermocycler significantly reduced the shear bond strength, with one exception-sandblasted samples with MKZ Primer. Standard ceramic surface preparation, involving only alumina sandblasting, does not provide a satisfactory bond. The use of etching with the Zircos-E system and primers had a positive effect on the strength of the zirconium-resin cement connection.

5.
Int J Mol Sci ; 24(5)2023 Feb 22.
Article in English | MEDLINE | ID: mdl-36901766

ABSTRACT

Due to the questionable durability of dental restorations, there is a need to increase the lifetime of composite restoration. The present study used diethylene glycol monomethacrylate/4,4'-methylenebis(cyclohexyl isocyanate) (DEGMMA/CHMDI), diethylene glycol monomethacrylate/isophorone diisocyanate (DEGMMA/IPDI) monomers, and bis(2,6-diisopropylphenyl)carbodiimide (CHINOX SA-1) as modifiers of a polymer matrix (40 wt% urethane dimethacrylate (UDMA), 40 wt% bisphenol A ethoxylateddimethacrylate (bis-EMA), and 20 wt% triethyleneglycol dimethacrylate (TEGDMA)). Flexural strength (FS), diametral tensile strength (DTS), hardness (HV), sorption, and solubility were determined. To assess hydrolytic stability, the materials were tested before and after two aging methods (I-7500 cycles, 5 °C and 55 °C, water and 7 days, 60 °C, 0.1 M NaOH; II-5 days, 55 °C, water and 7 days, 60 °C, 0.1 M NaOH). The aging protocol resulted in no noticeable change (median values were the same as or higher than the control value) or a decrease in the DTS value from 4 to 28%, and a decrease in the FS value by 2 to 14%. The hardness values after aging were more than 60% lower than those of the controls. The used additives did not improve the initial (control) properties of the composite material. The addition of CHINOX SA-1 improved the hydrolytic stability of composites based on UDMA/bis-EMA/TEGDMA monomers, which could potentially extend the service life of the modified material. Extended studies are needed to confirm the possible use of CHINOX SA-1 as an antihydrolysis agent in dental composites.


Subject(s)
Methacrylates , Polymethacrylic Acids , Bisphenol A-Glycidyl Methacrylate , Sodium Hydroxide , Materials Testing , Composite Resins , Polyethylene Glycols , Polyurethanes , Water
6.
Polymers (Basel) ; 15(4)2023 Feb 11.
Article in English | MEDLINE | ID: mdl-36850182

ABSTRACT

Custom mouthguards are used in various sports disciplines as a protection for teeth, temporomandibular joints, and soft tissues of the oral cavity from impact forces. The purpose of this research was to evaluate the mechanical properties of flexible polymeric 3D-printable materials and to select a material with the most favourable physical properties for making intraoral protectors. Four 3D-printable polymeric materials were selected for the evaluation: IMPRIMO LC IBT (Scheu-Dental, Iserlohn, Germany), Keyortho IBT (EnvisionTEC, Gladbeck, Germany), IBT (Formlabs, Somerville, MA, USA), and Ortho IBT (NextDent, Utrecht, Netherlands). A total of 176 samples (44 from each material) was 3D-printed using the stereolitography (SLA) technique. Tensile strength, flexural strength, notch-toughness, Shore hardness, sorption, and solubility tests were conducted. The materials were compared using a series of analyses of variance (one-way ANOVA) with Bonferroni post hoc tests. Statistical analyses were performed with the use of IBM SPSS Statistics 28.0.0 software (IBM, New York, NY, USA). Each material was assigned a score from 1 to 4 depending on the individual test results, and tests were given indexes according to the significance of the parameter in the mouthguard protective function. The number of points obtained by each material in each test was then multiplied by the test index, and the results were tabulated. The material with the highest result among the ones studied-most suitable for the application in mouthguard fabrication-was Keyortho IBT from EnvisionTEC.

7.
Materials (Basel) ; 15(14)2022 Jul 20.
Article in English | MEDLINE | ID: mdl-35888521

ABSTRACT

Materials with potential use as dental restoration should be evaluated in an aggressive environment. Such accelerated aging is widely used in other industries and allows the assessment of service life. In the presented study, three neat resins (UDMA/Bis-GMA/TEGDMA 70/10/20 wt.%, UDMA/Bis-GMA/TEGDMA 40/40/20 wt.% and UDMA/Bis-EMA/TEGDMA 40/40/20 wt.%) and three composites based on these matrices were tested before and after aging protocols (I-7500 cycles, 5 °C and 55 °C, water and 7 days, 60 °C, 0.1 M NaOH; II-5 days, 55 °C, water and 7 days, 60 °C, 0.1 M NaOH). Flexural strength (FS), diametral tensile strength (DTS) and hardness (HV) were determined. Applied aging protocols resulted in a decrease in the value of the FS, DTS and HV. Larger changes were noticed for the neat resins. Materials in which the content of bis-GMA was lower or substituted by bis-EMA showed better resistance to degradation. The choice of mixtures with monomers characterized by lower sorption values may favorably affect hydrolytic stability. It was shown that for composites there was a drastic decrease in hardness, which suggests a more superficial effect of the used protocols. However, degradation of the surface layer can result in a growing problem over time given that the mastication processes are an inherent element in the oral environment.

8.
Molecules ; 27(11)2022 May 30.
Article in English | MEDLINE | ID: mdl-35684448

ABSTRACT

The clinical performance of a dental restoration is strongly influenced by the complex and dynamically-changing oral environment; however, no standard procedure exists to evaluate this lifetime. This research provides an in-depth analysis of the effect of different aging procedures on the flexural strength (FS), diametral tensile strength (DTS) and hardness (HV) of selected dental materials (Resin F, Flow-Art and Arkon). Material structure was evaluated by scanning electron microscopy. It was found that each aging protocol had some influence on the tested properties, with continual erosion and degradation being observed. Greater mechanical degradation was observed for Resin F (neat resin) after the applied aging protocols, suggesting that a resin matrix is more susceptible for degradation. The most aggressive aging protocol was Protocol 5: 0.1 M NaOH, seven days, 60 °C. Further studies on the effect of artificial aging on dental materials should include a study of the thermal and chemical factors. A standardized aging procedure is crucial for improving the resistance of dental resin composite to oral conditions and their clinical performance.


Subject(s)
Composite Resins , Composite Resins/chemistry , Hardness , Materials Testing , Microscopy, Electron, Scanning , Stress, Mechanical , Surface Properties , Tensile Strength
9.
Materials (Basel) ; 15(7)2022 Apr 04.
Article in English | MEDLINE | ID: mdl-35407980

ABSTRACT

Bisphenol A-glycidyl methacrylate (bis-GMA) and urethane dimethacrylate (UDMA) are usually combined with low-viscosity monomers to obtain more desirable viscosity, handling characteristics and general properties. The present study determined the flexural strength (FS), flexural modulus (FM), diametral tensile strength (DTS), and hardness (HV) of five matrices and composites based on these resins. The polymerization shrinkage stress (PSS) was also studied for the composites. The polymer matrices were formed using bis-GMA and UDMA. TEGDMA, HEMA and HDDMA acted as co-monomers. The composites had 45 wt.% of filler content. The highest FS and FM were obtained from the UDMA/bis-GMA/TEGDMA/HEMA matrix and the composite (matrix + filler). The best DTS values were obtained from the UDMA/bis-GMA/HEMA matrix and the composite. One of the lowest values of FS, FM, and DTS was obtained from the UDMA/bis-GMA/HDDMA matrix and the composite. All the composites demonstrated similar hardness values. The lowest polymerization shrinkage stress was observed for the UDMA/bis-GMA/TEGDMA/HEMA composite, and the highest PSS was observed for the UDMA/bis-GMA/TEGDMA/HDDMA composite. The addition of HEMA had a positive effect on the properties of the tested materials, which may be related to the improved mobility of the bis-GMA and UDMA monomers.

10.
Materials (Basel) ; 14(11)2021 May 21.
Article in English | MEDLINE | ID: mdl-34064213

ABSTRACT

Most of the dental materials available on the market are still based on traditional monomers such as bisphenol A-glycidyl methacrylate (Bis-GMA), urethane dimethacrylate (UDMA), triethyleneglycol dimethacrylate (TEGDMA), and ethoxylated bisphenol-A dimethacrylate (Bis-EMA). The interactions that arise in the monomer mixture and the characteristics of the resulting polymer network are the most important factors, which define the final properties of dental materials. The use of three different monomers in proper proportions may create a strong polymer matrix. In this paper, fourteen resin materials, based on urethane dimethacrylate with different co-monomers such as Bis-GMA or Bis-EMA, were evaluated. TEGDMA was used as the diluting monomer. The flexural strength (FS), diametral tensile strength (DTS), and hardness (HV) were determined. The impacts of material composition on the water absorption and dissolution were evaluated as well. The highest FS was 89.5 MPa, while the lowest was 69.7 MPa. The median DTS for the tested materials was found to range from 20 to 30 MPa. The hardness of the tested materials ranged from 14 to 16 HV. UDMA/TEGDMA matrices were characterized by the highest adsorption values. The overall results indicated that changes in the materials' properties are not strictly proportional to the material's compositional changes. The matrices showed good properties when the composite contained an equal mixture of Bis-GMA/Bis-EMA and UDMA or the content of the UDMA monomer was higher.

11.
Materials (Basel) ; 14(3)2021 Jan 28.
Article in English | MEDLINE | ID: mdl-33525369

ABSTRACT

The successful restoration of teeth requires a good connection between the inlay and natural tissue. A strong bond may improve retention and reinforce tooth structure. The purpose of this study was to evaluate the influence of cement layer thickness on contraction stress generated during photopolymerization, and to determine the changes in stress state of the cement occurring during aging in water (over 84 days). Two cements were used: resin composite cement (NX3) and self-adhesive resin cement (Maxcem Elite Chroma). A cylindrical sample made of CuZn alloy was used to imitate the inlay. The stress state was measured by photoelastic analysis. The contraction stress of the inlay restoration was calculated for cement layer thicknesses of 25 µm, 100 µm, 200 µm, and 400 µm. For both tested materials, the lowest contraction stress was observed for the thinnest layer (25 µm), and this increased with thickness. Following water immersion, a significant reduction in contraction stress was observed due to hygroscopic expansion. Applying a thin layer (approximately 25 µm) of composite and self-adhesive resin cements resulted in high levels of expansion stresses (over -6 MPa) after water aging.

12.
Materials (Basel) ; 13(16)2020 Aug 10.
Article in English | MEDLINE | ID: mdl-32785055

ABSTRACT

Complex dental components which are individually tailored to the patient can be obtained due to new additive manufacturing technology. This paper reviews the metallic powders used in dental applications, the fabrication process (build orientation, process parameters) and post-processing processes (stress relieving, surface finishing). A review of the literature was performed using PubMed, ScienceDirect, Mendeley and Google Scholar. Over eighty articles were selected based on relevance to this review. This paper attempts to include the latest research from 2010 until 2020, however, older manuscripts (10 articles) were also selected. Over 1200 records were identified through the search; these were screened for title and/or summary. Over eighty articles were selected based on relevance to this review. In order to obtain a product which can be used in clinical applications, the appropriate manufacturing parameters should be selected. A discussion was made on optimal selective laser melting (SLM) parameters in dentistry. In addition, this paper includes a critical review of applied thermal treatment methods for Co-Cr alloys used in dentistry.

13.
Polymers (Basel) ; 12(4)2020 Apr 10.
Article in English | MEDLINE | ID: mdl-32290337

ABSTRACT

The paper reviews the environmental factors affecting ageing processes, and the degradation of resins, filler, and the filler-matrix interface. It discusses the current methods of testing materials in vitro. A review of literature was conducted with the main sources being PubMed. ScienceDirect, Mendeley, and Google Scholar were used as other resources. Studies were selected based on relevance, with a preference given to recent research. The ageing process is an inherent element of the use of resin composites in the oral environment, which is very complex and changes dynamically. The hydrolysis of dental resins is accelerated by some substances (enzymes, acids). Bonds formed between coupling agent and inorganic filler are prone to hydrolysis. Methods for prediction of long-term behaviour are not included in composite standards. Given the very complex chemical composition of the oral environment, ageing tests based on water can only provide a limited view of the clinical performance of biomaterial. Systems that can reproduce dynamic changes in stress (thermal cycling, fatigue tests) are better able to mimic clinical conditions and could be extremely valuable in predicting dental composite clinical performance. It is essential to identify procedure to determine the ageing process of dental materials.

14.
Materials (Basel) ; 12(15)2019 Aug 02.
Article in English | MEDLINE | ID: mdl-31382428

ABSTRACT

Prosthetic materials must exhibit adequate resistance to the oral environment. The aim of this paper was to study the resistance of selected cements used for cementing restorations (Breeze-composite, Adhesor Carbofine-zinc-polycarboxylate and IHDENT-Giz type II-glass-ionomer) against ethanol, soda and green tea solutions. The highest values of hardness and DTS (diametral tensile strength) were obtained by composite cement (HV = 15-31, DTS = 34-45 MPa). Ethanol solution had the greatest impact on the hardness value of composite cement, and soda solution on zinc-polycarboxylate cement. No significant differences were noted in the DTS values of composite cements after immersion in solvents; however, the DTS value of zinc-polycarboxylate cement increased after prolonged immersion time in ethanol and the DTS of glass-ionomer cement (IHDENT Giz type II) clearly decreased after submersion in soda solutions. Variation in pH across the range of 6 (tea) to 9 (soda solution) had a low impact on the properties of dental cements. Extended exposure to solvents appears to worsen the properties of cements.

15.
Molecules ; 24(2)2019 01 18.
Article in English | MEDLINE | ID: mdl-30669394

ABSTRACT

Contemporary self-etch and multi-mode adhesives were introduced to ensure a fast and reliable bonding procedure. Yet, in terms of bond strength and stability they failed to perform as well as two-bottle, etch-and-rinse adhesives, which remain the gold standard in terms of durability. The purpose of this study was to assess the shear bond strength (SBS) of dental adhesives to dentin with different application protocols. Two self-etch (Adper Easy One and Xeno V) and two multi-mode adhesives (Single Bond Universal and Prime&Bond One Select) were used in the study. The highest SBS was obtained for Single Bond Universal applied in three layers, while the lowest, for Xeno V applied in one layer. Other tested adhesives obtained the highest SBS when applied in three layers. For all tested adhesives, multi-layer application resulted in an increase in adhesive layer thickness, as observed in SEM. The increased thickness of the adhesive layer produced by triple application of unfilled adhesives corresponded with higher SBS values. The present study showed that using triple adhesive layers with simplified adhesive systems can be recommended to improve their performance. Due to differences in the composition of self-etch and universal adhesives, the exact application protocol is product dependent.


Subject(s)
Adhesives/chemistry , Dentin/chemistry , Mechanical Phenomena , Composite Resins/chemistry , Dental Cements/chemistry , Humans , Materials Testing , Shear Strength
16.
Polymers (Basel) ; 10(10)2018 Oct 02.
Article in English | MEDLINE | ID: mdl-30961019

ABSTRACT

Ion-releasing polymeric restorative materials seem to be promising solutions, due to their possible anticaries effect. However, acid functional groups (monomers) and glass filler increase hydrophilicity and, supposedly, water sorption. The purpose of the study was to evaluate the influence of water sorption of polymeric materials on the stress state at the restoration-tooth interface. Beautifil Bulk Fill Flow, Beautifil Flow Plus F00, Beautifil Flow F02, Dyract eXtra, Compoglass Flow, Ionosit, Glasiosite, TwinkiStar, Ionolux and Fuji II LC were used for the study. The stress state was measured using photoelastic analysis after: 0.5, 24, 72, 96, 168, 240, 336, 504, 672, 1344 and 2016 h. Moreover, water sorption, solubility and absorption dynamic were assessed. The water sorption, solubility and absorption dynamic of ion-releasing restorative materials are material dependent properties. The overall results indicated that the tested restorative materials showed significant stress decrease. The total reduction in contraction stress and water expansion stress was not observed for materials with low value of water sorption (Beautifil Bulk Fill, Dyract eXtra, Glasionosit and Twinky Star). The photoelastic method turned out to be inadequate to evaluate stress changes of resin modified glass-ionomer cement (RMGI, Fuji II LC and Ionolux).

SELECTION OF CITATIONS
SEARCH DETAIL
...