Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Med ; 12(23)2023 Dec 04.
Article in English | MEDLINE | ID: mdl-38068550

ABSTRACT

BACKGROUND: Patients with infectious complications related to the presence of cardiac implantable electronic devices (CIED) constitute a heterogeneous group, ranging from local pocket infection (PI) to lead-related infectious endocarditis (LRIE) infection spreading along the leads to the endocardium. The detection of isolated LRIE and the assessment of the spread of infection in a patient with PI is often difficult and requires complex imaging and microbiological tests. The aim of the current study is to evaluate the usefulness of new simple hematological parameters in detecting infectious complications in patients with CIED, differentiating vegetation and vegetation-like masses, and assessing the extent of infections in patients with PI. METHODS: A retrospective analysis of clinical data of 2909 patients (36.37% with CIED-related infections), undergoing transvenous lead extraction (TLE) procedures in three high-volume centres in the years 2006-2020, was conducted. Receiver operating characteristic (ROC) curve analysis was used to assess the sensitivity and specificity of neutrophil-to-lymphocyte ratio (NLR), neutrophil-to-platelet ratio (NPR), and lymphocyte-to-platelet ratio (LPR) in the diagnosis of CIED infections, evaluate the spread of the infectious process in patients with PI and differentiate additional structures related to the presence of lead. RESULTS: The values of NLR and NPR were significantly higher in infectious patients than non-infectious controls (3.07 vs. 2.59; p < 0.001, and 0.02 vs. 0.01; p = 0.008) and the area under the ROC curve (AUC) was 0.59; p < 0.001 and 0.56; p < 0.001, respectively. The high specificity of the new markers in detecting the infectious process was demonstrated: 72.82% for NLR (optimal cut-off value: 3.06) and 79.47% for NPR (optimal cut off value: 0.02). The values of NLR and NPR were significantly higher in patients with vegetations than in non-infectious patients with the presence of additional lead-related masses (3.37 vs. 2.61; p < 0.001 and 0.03 vs. 0.02; p = 0.008). The AUC of NLR and NPR for the prediction of vegetations was 0.65; p < 0.001 and 0.60; p < 0.001 with the highest specificity of NPR (82.78%) and an optimal cut-off value of 0.03. NLR and NPR were higher in patients with LRIE compared to isolated PI (4.11 vs. 2.56; p < 0.001 and 0.03 vs. 0.02; p < 0.001) and the ROC curve analysis for coexistence LRIE with PI showed the AUC for NLR: 0.57; p < 0.001 and AUC for NPR: 0.55; p = 0.001. High specificity in the detection of coexistence between PI and LRIE was demonstrated for NLR (87.33%), with an optimal cut-off value of 3.13. CONCLUSIONS: Novel hematological markers (NLR and NPR) are characterized by high specificity in the initial diagnosis of CIED infections, with optimal cut-off values of 3.06 and 0.02. NLR is also useful in the assessment of the spread of infection in patients with PI, with a calculated optimal cut-off value of 3.13. NPR may be helpful in the differentiation of vegetation and vegetation-like masses with an optimal cut-off value of 0.03.

2.
Article in English | MEDLINE | ID: mdl-36231579

ABSTRACT

BACKGROUND: Damage to the tricuspid valve (TVD) is now considered either a major or minor complication of the transvenous lead extraction procedure (TLE). As yet, the risk factors and long-term survival after TLE in patients with TVD have not been analyzed in detail. METHODS: This post hoc analysis used clinical data of 2631 patients (mean age 66.86 years, 39.64% females) who underwent TLE procedures performed in three high-volume centers. The risk factors and long-term survival of patients with worsening tricuspid valve (TV) function after TLE were analyzed. RESULTS: In most procedures (90.31%), TLE had no negative influence on TV function, but in 9.69% of patients, a worsening of tricuspid regurgitation (TR) to varying degrees was noted, including significant dysfunction in 2.54% of patients. Risk factors of TLE relating to severe TVD were: TLE of pacing leads (5.264; p = 0.029), dwell time of the oldest extracted lead (OR = 1.076; p = 0.032), strong connective scar tissue connecting a lead with tricuspid apparatus (OR = 5.720; p < 0.001), and strong connective scar tissue connecting a lead with the right ventricle wall (OR = 8.312; p < 0.001). Long-term survival (1650 ± 1201 [1-5519] days) of patients with severe TR was comparable to patients without tricuspid damage related to TLE. CONCLUSIONS: Severe tricuspid valve damage related to TLE is relatively rare (2.5%). The main risk factors for the worsening of TV function are associated with a longer lead dwell time (more often the pacing lead), causing stronger connective tissue scars connecting the lead to the tricuspid apparatus and right ventricle. TVD is unlikely to affect long-term survival after TLE.


Subject(s)
Pacemaker, Artificial , Tricuspid Valve Insufficiency , Aged , Cicatrix/complications , Female , Humans , Lead , Male , Pacemaker, Artificial/adverse effects , Retrospective Studies , Treatment Outcome , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/etiology
3.
J Clin Med ; 11(14)2022 Jul 06.
Article in English | MEDLINE | ID: mdl-35887692

ABSTRACT

Infections involving cardiac implantable electronic devices (CIEDs) occur at different times after device-related procedures. The aim of this study was to investigate the timing of onset and factors influencing the occurrence of all types of CIED infections to identify the type of pathogen and to examine the long-term survival of patients with all types of CIED infections. We performed a post hoc analysis of the clinical data from 3344 patients who underwent transvenous lead extraction (TLE) at a single high-volume center between 2006 and 2020, including a group of 890 patients with CIED infections. The occurrence of pocket infection (PI), lead-related infective endocarditis (LRIE) and PI coexisting with LRIE (PI + LRIE) was assessed at the following time intervals: 0−12 months, 13−36 months and > 36 months since last CIED-related procedure. In the study group, there were 274 (30.79%) early infections, 266 (29.89%) delayed infections and 350 (39.32%) late infections. Pocket infection was the most common early complication (97; 39.43%), while LRIE was predominant over 36 months from the last CIED procedure (172; 54.09%). The most common early infections were PIs that were associated with the preceding CIED-related procedure. Late LRIE was most likely to occur in patients with intracardiac lead abrasion. The probability of early versus late LRIE was higher in patients with CoNS cultures. The timing of infection onset irrespective of its type does not affect long-term survival after transvenous lead extraction. The majority of infectious complications (69%) occur more than 12 months after the last CIED-related procedure. Early infections are probably associated with pocket contamination during CIED-related procedure, while delayed and late systemic infections are related to other lead-dependent factors (especially to intracardiac lead abrasion). Time to LRIE onset is associated with pathogen type. The timing of symptom onset does not affect long-term survival after TLE.

4.
J Clin Med ; 11(1)2021 Dec 24.
Article in English | MEDLINE | ID: mdl-35011829

ABSTRACT

BACKGROUND: Lead-related tricuspid valve dysfunction (LDTVD) has not been studied in a large population and its management remains controversial. METHODS: An analysis of the clinical data of 2678 patients undergoing transvenous lead extraction (TLE) in years 2008-2021 was conducted, with a separate group of 119 patients with LDTVD. Potential risk factors for LDTVD, improvement in valve function, and long-term prognosis after TLE were assessed. RESULTS: LDTVD was diagnosed in 4.44% of patients referred for lead extraction due to different reasons. The most common mechanism of LDTVD was propping upward or clamping down the leaflet by the lead (85.71%). The probability of LDTVD was higher in female sex, patients with valvular heart disease, atrial fibrillation, heart failure, large right ventricle and high pulmonary artery systolic pressure, the presence of only pacing lead, and in case of collision of the lead with tricuspid valve and adhesion of the lead to the heart structures. The prognosis of patients with LDTVD was worse, however, patients with improved valve function after TLE showed a significantly better long-term survival. CONCLUSIONS: Lead dependent tricuspid valve dysfunction is a potentially serious condition that requires thorough diagnostics and thoughtful management. The risk factors for LDTVD are primarily related to the course of the lead and its adhesion to the heart structures. Improvement of tricuspid valve function after TLE is observed in 35.29% of patients Patients with LDTVD have a worse long-term survival, but the improvement in valve function following TLE contributes to a significant reduction in mortality.

5.
J Clin Med ; 9(5)2020 May 08.
Article in English | MEDLINE | ID: mdl-32397115

ABSTRACT

BACKGROUND: Transesophageal echocardiography (TEE) is a valuable tool for monitoring the patient during transvenous lead extraction (TLE), but the direct impact of TEE on the effectiveness and safety of TLE has not yet been documented. METHODS: The effectiveness of TLE and short-term survival were compared between two groups of patients: 2106 patients in whom TEE was performed before and after TLE and 1079 individuals in whom continuous TEE monitoring was used. The procedure-related risk of major complications was assessed using a predictive SAFeTY TLE score. RESULTS: The patients monitored by TEE were characterized by older age, more comorbidities and higher SAFeTY TLE scores (6.143 ± 4.395 vs. 5.593 ± 4.127; p = 0.004). Complete procedural success was significantly higher in the TEE-guided group (97.683% vs. 95.442%, p < 0.01). The rate of serious complications in the TEE-guided group was lower than the predictive SAFeTY TLE score-a reduction of 28.75% (p < 0.05). Periprocedural mortality in the TEE-guided and non-TEE-guided groups was zero vs. six deaths (p = 0.186). Short-term survival was comparable between the groups. CONCLUSIONS: Transesophageal echocardiography as a monitoring tool during transvenous lead extraction provides valuable results-higher rates of complete procedural success and a reduced risk of the most severe complications, thus preventing periprocedural deaths.

6.
Front Neurol ; 9: 392, 2018.
Article in English | MEDLINE | ID: mdl-29910769

ABSTRACT

The aim of the present study is to present the results of the assessment of clinical application of the robotic assistant for patients suffering from mild cognitive impairments (MCI) and Alzheimer Disease (AD). The human-robot interaction (HRI) evaluation approach taken within the study is a novelty in the field of social robotics. The proposed assessment of the robotic functionalities are based on end-user perception of attractiveness, usability and potential societal impact of the device. The methods of evaluation applied consist of User Experience Questionnaire (UEQ), AttrakDiff and the societal impact inventory tailored for the project purposes. The prototype version of the Robotic Assistant for MCI patients at Home (RAMCIP) was tested in a semi-controlled environment at the Department of Neurology (Lublin, Poland). Eighteen elderly participants, 10 healthy and 8 MCI, performed everyday tasks and functions facilitated by RAMCIP. The tasks consisted of semi-structuralized scenarios like: medication intake, hazardous events prevention, and social interaction. No differences between the groups of subjects were observed in terms of perceived attractiveness, usability nor-societal impact of the device. The robotic assistant societal impact and attractiveness were highly assessed. The usability of the device was reported as neutral due to the short time of interaction.

7.
Front Neurol ; 8: 228, 2017.
Article in English | MEDLINE | ID: mdl-28620342

ABSTRACT

OBJECTIVE: We focused on identifying the requirements and needs of people suffering from Alzheimer disease and early dementia stages with relation to robotic assistants. METHODS: Based on focus groups performed in two centers (Poland and Spain), we created surveys for medical staff, patients, and caregivers, including: functional requirements; human-robot interaction, the design of the robotic assistant and user acceptance aspects. Using Likert scale and analysis made on the basis of the frequency of survey responses, we identified users' needs as high, medium, and low priority. RESULTS: We gathered 264 completed surveys (100 from medical staff, 81 from caregivers, and 83 from potential users). Most of the respondents, almost at the same level in each of the three groups, accept robotic assistants and their support in everyday life. High level priority functional requirements were related to reacting in emergency situations (calling for help, detecting/removing obstacles) and to reminding about medication intake, about boiling water, turning off the gas and lights (almost 60% of answers). With reference to human-robot interaction, high priority was given to voice operated system and the capability of robotic assistants to reply to simple questions. CONCLUSION: Our results help in achieving better understanding of the needs of patients with cognitive impairments during home tasks in everyday life. This way of conducting the research, with considerations for the interests of three stakeholder groups in two autonomic centers with proven experience regarding the needs of our patient groups, highlights the importance of obtained results.

SELECTION OF CITATIONS