Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Pathologica ; 112(1): 17-24, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32202536

ABSTRACT

Intraductal carcinoma of the prostate (IDC-P) is a diagnostic entity characterized by architecturally or cytologically malignant-appearing prostatic glandular epithelium confined to prostatic ducts. Despite its apparent in situ nature, this lesion is associated with aggressive prostatic adenocarcinoma and is a predictor for poor prognosis when identified on biopsy or radical prostatectomy. This review discusses diagnosis, clinical features, histogenesis, and management of IDC-P, as well as current research and controversies surrounding this entity.


Subject(s)
Carcinoma, Intraductal, Noninfiltrating/diagnosis , Carcinoma, Intraductal, Noninfiltrating/genetics , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/genetics , Carcinoma, Intraductal, Noninfiltrating/therapy , Diagnosis, Differential , Humans , Male , Prostatectomy/trends , Prostatic Neoplasms/therapy
2.
Acad Med ; 91(6): 813-20, 2016 06.
Article in English | MEDLINE | ID: mdl-27028031

ABSTRACT

PURPOSE: Provision of high-value care is a milestone in physician training. The authors evaluated the effect of a housestaff-led initiative on laboratory testing rates. METHOD: Vanderbilt University Medical Center's Choosing Wisely steering committee, led by housestaff with faculty advisors, sought to reduce unnecessary daily basic metabolic panel (BMP) and complete blood count (CBC) testing on inpatient general medicine and surgical services. Intervention services received a didactic session followed by regular data feedback with goal rates and peer comparison. Testing rates during January 1, 2013-February 9, 2015, were compared on intervention services and control services using a difference-in-differences analysis and an interrupted time-series analysis with segmented linear regression. RESULTS: Compared with concurrent controls, the mean number of BMP tests per patient day decreased by an additional 0.23 (95% CI 0.17-0.29) on medical housestaff and 0.15 (95% CI 0.09-0.21) on hospitalist intervention services. Daily CBC tests decreased by an additional 0.28 (95% CI 0.23-0.33) on medical housestaff, 0.08 (95% CI 0.03-0.13) on hospitalist, and 0.12 (95% CI 0.05-0.20) on surgical housestaff intervention services. Patients with lab-free days (0 labs ordered in 24 hours) increased by an additional 4.1 percentage points (95% CI 2.1-6.1) on medical housestaff and 9.7 percentage points (95% CI 6.6-12.8) on hospitalist intervention services. There were no adverse changes in length of stay or intensive care unit transfer, in-hospital mortality, or 30-day readmission rates. CONCLUSIONS: A housestaff-led intervention utilizing education and data feedback with goal setting and peer comparison resulted in safe, significant reductions in daily laboratory testing rates.


Subject(s)
Clinical Laboratory Techniques/statistics & numerical data , Faculty, Medical/organization & administration , Hospitalists/organization & administration , Interdisciplinary Communication , Internship and Residency/organization & administration , Unnecessary Procedures/statistics & numerical data , Education, Medical, Continuing/methods , Education, Medical, Continuing/organization & administration , Humans , Internship and Residency/methods , Leadership , Linear Models , Quality Indicators, Health Care/statistics & numerical data , Retrospective Studies , Tennessee
3.
EuroIntervention ; 11(4): 433-41, 2015 Aug.
Article in English | MEDLINE | ID: mdl-24769439

ABSTRACT

AIMS: To evaluate the short-, mid- and long-term safety, efficacy and vascular physiology of Axetis silicon dioxide (SiO2, abrading the micropores) inert-coated stent implantation in a randomised preclinical setting. METHODS AND RESULTS: Coronary arteries of domestic pigs were randomised to receive either Axetis or BMS (same design) stents with one-, three- and six-month follow-up (FUP), controlled by coronary angiography, optical coherence tomography (OCT), intravascular ultrasound (IVUS) and histology (n=32). The time-dependent vasomotor reaction of coronary arteries to stenting was measured using modified myography (n=12). Complete endothelialisation of the Axetis stent was confirmed by OCT, IVUS and histology at one-month FUP. Histopathology revealed continuous healing of the vessel wall with a gradual reduction of inflammation and fibrin score during the six-month FUP in both stent types. Significantly smaller neointimal area and %area stenosis were measured in Axetis stents compared with BMS at each FUP time point. Vascular reactivity measurements showed significantly better endothelium-dependent vasodilation of stented arteries with Axetis implantation. CONCLUSIONS: Implantation of the Axetis SiO2-coated stent resulted in a significantly better safety, efficacy and vessel physiology profile compared with BMS of the same design with a continuous decrease in vessel inflammation during the six-month FUP.


Subject(s)
Coated Materials, Biocompatible , Coronary Vessels , Metals , Percutaneous Coronary Intervention/instrumentation , Silicon Dioxide , Stents , Animals , Coronary Angiography , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Coronary Vessels/physiopathology , Feasibility Studies , Female , Male , Materials Testing , Models, Animal , Neointima , Percutaneous Coronary Intervention/adverse effects , Prosthesis Design , Sus scrofa , Time Factors , Tomography, Optical Coherence , Ultrasonography, Interventional , Vasodilation
4.
JACC Cardiovasc Interv ; 5(7): 741-51, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22814779

ABSTRACT

OBJECTIVES: This study sought to determine the time dependency of the endothelium-dependent and -independent vascular responses after percutaneous coronary intervention (PCI) with drug-eluting (DEB) or plain balloons, bare-metal (BMS), and drug-eluting (DES) stents, or controls. BACKGROUND: Long-term endothelial dysfunction after DES implantation is associated with delayed healing and late thrombosis. METHODS: Domestic pigs underwent PCI using DEB or plain balloon, BMS, or DES. The dilated and stented segments, and the proximal reference segments of stents and control arteries were explanted at 5-h, 24-h, 1-week, and 1-month follow-up (FUP). Endothelin-induced vasoconstriction and endothelium-dependent and -independent vasodilation of the arterial segments were determined in vitro and were related to histological results. RESULTS: DES- and BMS-treated arteries showed proneness to vasoconstriction 5 h post-PCI. The endothelium-dependent vasodilation was profoundly (p < 0.05) impaired early after PCI (9.8 ± 3.7%, 13.4 ± 9.2%, 5.7 ± 5.3%, and 7.6 ± 4.7% using plain balloon, DEB, BMS, and DES, respectively), as compared with controls (49.6 ± 9.5%), with slow recovery. In contrast to DES, the endothelium-related vasodilation of vessels treated with plain balloon, DEB, and BMS was increased at 1 month, suggesting enhanced endogenous nitric oxide production of the neointima. The endothelium-independent (vascular smooth muscle-related) vasodilation decreased significantly at 1 day, with slow normalization during FUP. All PCI-treated vessels exhibited imbalance between vasoconstriction-vasodilation, which was more pronounced in DES- and BMS-treated vessels. No correlation between histological parameters and vasomotor function was found, indicating complex interactions between the healing neoendothelium and smooth muscle post-PCI. CONCLUSIONS: Coronary arteries treated with plain balloon, DEB, BMS, and DES showed time-dependent loss of endothelial-dependent and -independent vasomotor function, with imbalanced contraction/dilation capacity.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease/therapy , Coronary Vasospasm/pathology , Drug-Eluting Stents , Endothelium, Vascular/pathology , Analysis of Variance , Animals , Coronary Artery Disease/drug therapy , Disease Models, Animal , Swine , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...