Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Interv Neuroradiol ; 22(4): 438-44, 2016 Aug.
Article in English | MEDLINE | ID: mdl-26921167

ABSTRACT

OBJECTIVES: A higher rate of embolization is considered a disadvantage of carotid stenting (CAS), when compared with carotid endarterectomy. Plaques in the aortic arch (AA) and the common carotid artery (CCA) may be additional sources of embolization to stented internal carotid plaques during CAS. In this study, we aimed to investigate the relationship between these plaques and intracerebral embolization. METHODS: We analyzed the occurrence and composition of plaques in the AA and CCA by computed tomography angiography (CTA) in 101 consecutive cases of CAS. Cases of peri-procedural embolization were detected on diffusion-weighted imaging as lesions demonstrating diffusion restriction. We applied the χ(2) and Fisher's exact tests, as well as logistic regression models. RESULTS: The occurrence of plaques in the AA and CCA was significantly related to the appearance of new diffusion-weighted imaging lesions (p = 0.013 and p = 0.004, respectively). Patients with soft plaques in the AA or CCA had a significantly higher risk of embolization than those without plaques (p = 0.012 and p = 0.006, respectively). In contrast, homogeneously calcified plaques did not pose significantly higher risks. CONCLUSIONS: Soft plaques in the AA and CCA result in a substantial risk of embolization during CAS. Use of a CTA examination of the AA and the CCA in patients with carotid stenosis may help to select lower-risk patients for CAS.


Subject(s)
Aorta, Thoracic/pathology , Carotid Artery, Common/pathology , Carotid Stenosis/therapy , Intracranial Embolism/etiology , Plaque, Atherosclerotic/complications , Stents , Aged , Carotid Artery, Common/diagnostic imaging , Carotid Stenosis/diagnostic imaging , Computed Tomography Angiography , Diffusion Magnetic Resonance Imaging , Female , Humans , Intracranial Embolism/diagnostic imaging , Male , Middle Aged , Patient Selection , Retrospective Studies , Risk Factors , Treatment Outcome
2.
Eur Radiol ; 20(7): 1772-6, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20033177

ABSTRACT

OBJECTIVES: To evaluate the safety and feasibility of the use of covered stents for the treatment of extracranial carotid artery stenosis caused by highly embologenic plaques, and to study the long-term outcome of patients receiving such covered stents. METHODS: Between 2002 and 2007, 46 patients (63% symptomatic, 78.3% male, 67 +/- 8.6 years old) with internal carotid artery stenosis caused by embologenic plaques or restenosis were treated with self-expanding covered stents (Symbiot, Boston Scientific). Pre-dilatation or protecting devices were not used. Post-dilatation was applied in every patient. Each patient was followed long-term. The outcome measures were the occurrence of neurological events, and the development of in-stent restenosis, as detected by clinical examination and duplex ultrasound. RESULTS: The technical success rate of stenting was 100%. There were no neurological complications in the peri-procedural period. The mean follow-up period was 34.3 +/- 27.7 months (the rate of patients lost to follow-up was 15.2%) during which no stroke or stroke-related deaths occurred. Restenosis was detected in 3 patients (6.5%). CONCLUSION: Covered stents provide efficient peri- and post-procedural protection against neurological complications due to embolisation from high-risk plaques during carotid artery stenting. Restenosis of covered stents appears to be infrequent during long-term follow-up.


Subject(s)
Carotid Artery, Internal , Carotid Stenosis/therapy , Stents , Aged , Aged, 80 and over , Consumer Product Safety , Feasibility Studies , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies
3.
Stroke ; 35(12): 2862-6, 2004 Dec.
Article in English | MEDLINE | ID: mdl-15514173

ABSTRACT

BACKGROUND AND PURPOSE: Protection devices are increasingly used in carotid artery stenting. However, no randomized trial has been conducted to evaluate the efficacy of such devices, and arguments have also been formulated against their routine use. We set out to investigate the complication rates associated with carotid artery stenting performed without protection devices. Applicability of covered stents in the carotid system was also evaluated. METHODS: Between January 2001 and July 2003, 245 consecutive patients (260 hemispheres) underwent carotid artery stenting. No protection devices were applied. Covered stents were implanted in 31 (12.1%) cases. The incidence of complications during the intervention and the subsequent 30-day follow-up period was recorded. RESULTS: The technical success rate was 98.8%. One postprocedural nonneurological death (0.4%) occurred. Neurological complications (inclusive of transient ischemic attacks) were observed in 14 cases (5.4%). The rate of major complications (death, major stroke, and myocardial infarction) was 1.6% among the symptomatic and 1.5% among the asymptomatic cases. The rate of minor strokes was 3.2% in the symptomatic and 1.5% in the asymptomatic group. Of the neurological complications, 64.3% occurred postprocedurally. No ipsilateral neurological complications were detected in the subgroup treated with covered stents. CONCLUSIONS: Carotid artery stenting without protection devices appears to be safe. Most of the neurological complications could not have been prevented with protection devices, because they occurred after the intervention. The application of covered stents may reduce the rate of embolization-related complications in the periprocedural period.


Subject(s)
Carotid Stenosis/surgery , Stents , Aged , Aged, 80 and over , Catheterization , Female , Humans , Intraoperative Complications , Male , Postoperative Complications , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...