Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Cardiovasc Electrophysiol ; 26(10): 1063-8, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26076115

ABSTRACT

BACKGROUND: Single-shot ablation devices for pulmonary vein isolation (PVI) in patients with symptomatic atrial fibrillation (AF) have been increasingly used in clinical practice. OBJECTIVE: A novel mapping-system integrated irrigated multipolar circular ablation catheter (nMARQ) has been introduced for PVI but data on larger patient cohorts on acute safety and efficacy are lacking. METHODS: A total of 145 consecutive patients undergoing AF ablation treated with the nMARQ underwent endoscopic evaluation of esophageal thermal damage (EDEL) and brain MRI for detection of silent cerebral events (SCE). During the course of our experience different modifications of the ablation strategy, including energy delivery at the left atrial posterior wall, were evaluated. RESULTS: Effective PVI was achieved in 99% of all PVs during a mean procedure-duration of 115 (±36) minutes and ablation-duration of 18 (±8) minutes. Acute major complications occurred in 3 patients (2.1%) and asymptomatic complications like SCE in 26% and EDEL in 21%. There was a significant reduction in EDEL when not using a thermal esophageal probe (0% vs. 28%, P < 0.0001). Ablation under oral anticoagulation led to lower SCE incidences compared to interrupted anticoagulation regimen (15% vs. 31%, P = 0.7). Out of 65 patients with completed 12-month follow-up, 43 (66%) were in stable sinus rhythm. CONCLUSIONS: PVI using the nMARQ is safe and effective in patients with symptomatic AF. Not using an esophageal temperature probe during ablation has relevantly reduced the incidence of EDEL. Ablations under continued oral anticoagulation have reduced incidence of SCE. Further studies on long-term efficacy are needed.


Subject(s)
Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Catheter Ablation/instrumentation , Catheter Ablation/statistics & numerical data , Postoperative Complications/epidemiology , Therapeutic Irrigation/statistics & numerical data , Acute Disease , Atrial Fibrillation/diagnosis , Body Surface Potential Mapping/instrumentation , Body Surface Potential Mapping/methods , Body Surface Potential Mapping/statistics & numerical data , Catheter Ablation/methods , Cohort Studies , Comorbidity , Equipment Design , Equipment Failure Analysis , Female , Germany/epidemiology , Humans , Male , Middle Aged , Prevalence , Pulmonary Veins/surgery , Risk Factors , Therapeutic Irrigation/instrumentation , Therapeutic Irrigation/methods , Treatment Outcome
2.
Heart Rhythm ; 12(7): 1464-9, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25847474

ABSTRACT

BACKGROUND: Endoscopically detected esophageal lesions (EDELs) have been identified in apparently asymptomatic patients after catheter ablation of atrial fibrillation (AF). The use of esophageal probes to monitor luminal esophageal temperature (LET) during catheter ablation to protect esophageal damage is currently controversial. OBJECTIVE: The purpose of this study was to investigate the impact of the use of esophageal temperature probes during AF catheter ablation on the incidence of EDELs. METHODS: Eighty consecutive patients (mean age 63.8 ± 11.36 years; 68.8% men) with symptomatic, drug-refractory paroxysmal (n = 52, 65%) or persistent AF who underwent left atrial radiofrequency catheter ablation were prospectively enrolled. Posterior wall ablation was power limited (≤25 W). In the first 40 patients, LET was monitored continuously (group A), whereas no esophageal temperature probe was used in group B (n = 40 patients). Assessment of EDEL was performed by endoscopy within 2 days after radiofrequency catheter ablation. RESULTS: Overall, 13 patients (16%) developed EDELs after AF ablation. The incidence of EDELs was significantly higher in group A than group B (30% vs 2.5%, P < .01). Within group A, patients who developed EDEL had higher maximal LET during AF ablation than patients without EDEL (40.97 ± 0.92°C vs 40.14 ± 1.1°C, P = .02). Multivariable logistic regression analysis revealed the use of an esophageal temperature probe as the only independent predictor for the development of EDEL (odds ratio 16.7, P < .01). CONCLUSION: The use of esophageal temperature probes in the setting of AF catheter ablation per se appears to be a risk factor for the development of EDEL.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Esophagus/injuries , Heart Atria , Postoperative Complications , Thermometry , Aged , Body Mass Index , Catheter Ablation/adverse effects , Catheter Ablation/methods , Esophageal Fistula/diagnosis , Esophageal Fistula/epidemiology , Esophageal Fistula/etiology , Esophagoscopy/methods , Female , Germany , Heart Atria/pathology , Heart Atria/surgery , Hot Temperature/adverse effects , Humans , Incidence , Male , Middle Aged , Monitoring, Intraoperative/adverse effects , Monitoring, Intraoperative/methods , Postoperative Complications/diagnosis , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Risk Assessment , Risk Factors , Thermometry/adverse effects , Thermometry/methods
3.
Indian Pacing Electrophysiol J ; 14(5): 240-9, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25408564

ABSTRACT

BACKGROUND: Silent cerebral events (SCE) have been identified on magnetic resonance imaging (MRI) in asymptomatic patients after atrial fibrillation (AF) ablation. Procedural determinants influencing the risk for SCE still remain unclear. OBJECTIVE: Comparing the risk for SCE depending on exchanges of catheters (ExCath) over a single transseptal sheath. METHODS: 88 Patients undergoing pulmonary vein isolation (PVI) only ablation using either single-tip or balloon-based technique underwent pre- and post-ablation cerebral MRI. Ablations were either performed with double transseptal access and without exchanging catheters over the transseptal sheaths (group 1: no ExCath) or after a single transseptal access and exchanges of therapeutic and diagnostic catheters (group 2: ExCath). Differences in regard to SCE rates were analyzed. Multivariate analysis was performed to identify factors related to the risk for SCE. RESULTS: Included patients underwent PVI using single tip irrigated radiofrequency in 41, endoscopic laser balloon in 27 and cryoballoon in 20 cases. Overall SCE were identified in 23 (26%) patients. In group 1 (no ExCath; N=46) 6 patients (13%) and in group 2 (N=42) 17 patients (40%) had documented SCE (p=0.007). The applied ablation technology did not affect SCE rate. In multivariate analysis age (OR 1.1, p=0.03) and catheter exchanges over a single transseptal sheath (OR 12.1, p=0.007) were the only independent predictors of a higher risk for SCE. CONCLUSIONS: Exchanging catheters over a single transseptal access to perform left atrial ablation is associated with a significantly higher incidence of SCE compared to an ablation technique using different transseptal accesses for therapeutic and diagnostic catheters.

SELECTION OF CITATIONS
SEARCH DETAIL
...