Herzschrittmacherther Elektrophysiol ; 34(4): 326-329, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37917362

ABSTRACT

Electrical storm due to recurrent ventricular tachycardias (VTs) is a life-threatening arrhythmic emergency. The authors present a case report of a 69-year-old male patient with VT storm of non-ischemic etiology. Despite optimal medical treatment escalated by amiodarone antiarrhythmic drug therapy, the patient experienced multiple implantable cardioverter defibrillator (ICD) shocks. An electrophysiological study revealed an epicardial substrate; however, considering the patient's extreme obesity and active anticoagulant effect, catheter ablation was deemed to be unfeasible. Subsequently, mexiletine was added to the patient's drug regimen, resulting in successful control of arrhythmias during the following 6 months. Although the most recent European guidelines for the management of patients with ventricular arrhythmias mention mexiletine only for the treatment of LQT3 patients, its use for treatment-refractory VT storm seems to also be an important indication area.


Subject(s)
Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Male , Humans , Aged , Mexiletine/therapeutic use , Treatment Outcome , Anti-Arrhythmia Agents/therapeutic use , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/drug therapy , Catheter Ablation/methods