Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Gastrointest Endosc ; 77(5): 784-92, 2013 May.
Article in English | MEDLINE | ID: mdl-23453293

ABSTRACT

BACKGROUND: EUS-guided FNA (EUS-FNA) is an established technique for the cytologic diagnosis of pancreatic disease. Attempts to obtain adequate histologic specimens have yielded variable and mostly insufficient results. OBJECTIVE: To evaluate the safety, feasibility, and quality of histologic biopsy specimens obtained by using a new cryobiopsy probe and to compare them with standard EUS-FNA and (laparoscopic) trucut biopsy specimens of pancreatic tissue. DESIGN: Animal non-survival study. INTERVENTION: Eighty-four pancreatic biopsy specimens (12 per group) were obtained in 4 anesthetized pigs by using one of the following the 18-gauge flexible cryoprobe; a conventional, 19-gauge, EUS-FNA needle; or a rigid, trucut biopsy device (18 gauge). The latter, used in laparoscopic surgery, was considered as the criterion standard for obtaining histology specimens. MAIN OUTCOME MEASUREMENTS: Specimens were evaluated for artifacts and specimen quality by a blinded pathologist who used a 7-point Likert scale to assess histologic adequacy. Biopsy size and bleeding time after biopsy also were recorded. RESULTS: The new cryoprobe was equivalent to the rigid, trucut needle and superior (P < .001) to the conventional 19-gauge FNA needles with respect to artifacts, quality of the specimen, biopsy specimen size, and bleeding. LIMITATIONS: Animal model. CONCLUSION: EUS-guided cryobiopsy was associated with better specimen quality for histologic analysis and a shorter bleeding time compared with a conventional 19-gauge FNA needle in the animal model. It is a promising new technique for histologic examination of pancreatic tissue.


Subject(s)
Cold Temperature , Endoscopic Ultrasound-Guided Fine Needle Aspiration/instrumentation , Endoscopic Ultrasound-Guided Fine Needle Aspiration/standards , Pancreas/pathology , Postoperative Hemorrhage/etiology , Animals , Artifacts , Cadaver , Endoscopic Ultrasound-Guided Fine Needle Aspiration/adverse effects , Humans , Prospective Studies , Single-Blind Method , Swine , Time Factors
2.
Respiration ; 80(2): 127-32, 2010.
Article in English | MEDLINE | ID: mdl-20160432

ABSTRACT

BACKGROUND: Cryoextraction is a procedure used for the recanalization of obstructed airways caused by visible exophytic endobronchial tumor. Biopsy samples obtained by this technique have been shown to be useful for histological assessment. OBJECTIVES: The aim of the present animal study was to systematically evaluate biopsy size, histological quality and bleeding risk after cryobiopsy with new, flexible cryoprobes in comparison with forceps biopsy, serving as the gold standard. METHODS: Biopsies were obtained from anesthetized pigs with the flexible bronchoscopy technique, and evaluated histologically with respect to their size and quality. Bleeding frequency, bleeding duration and histological changes in the biopsy bed were also recorded. RESULTS: Cryobiopsies were significantly larger than forceps biopsies. The size of cryobiopsies was dependent on the freezing time. The histological quality of the cryobiopsy specimenswas not impaired by the freezing process, whereas forceps biopsies showed typical crush artifacts. Despite the larger defects left in the tracheobronchial system after cryobiopsy, bleeding frequency and duration were not higher compared to forceps biopsy. CONCLUSIONS: Since cryobiopsy sampling is not associated with a higher bleeding risk compared with forceps biopsy, this new biopsy technique offers--in addition to a good specimen quality--a safe and valuable tool with the potential of improving the outcome of diagnostic endoscopy.


Subject(s)
Bronchoscopy , Cryosurgery/methods , Lung/pathology , Animals , Biopsy/adverse effects , Biopsy/instrumentation , Biopsy/methods , Blood Loss, Surgical/statistics & numerical data , Cryosurgery/adverse effects , Prospective Studies , Swine
3.
Urology ; 75(5): 1217-21, 2010 May.
Article in English | MEDLINE | ID: mdl-19589575

ABSTRACT

OBJECTIVES: To evaluate a newly developed computer-controlled cutting system for the generation of standardized resections and to systematically compare the hemostatic properties and tissue effect of 2 cutting modes, namely, AUTO CUT and DRY CUT used in urologic procedures. METHODS: An isolated perfused kidney model was used to assess blood loss and coagulation depth after resection of tissue specimens of standardized geometry, size, and cutting velocity with a resection loop. Three different effect settings (E1, E3, and E6; 200 W) of the electrosurgical modes AUTO CUT and DRY CUT were compared. Blood loss was determined semiquantitatively by weighing a swab before and after placing it onto the resection area. The coagulation depth was estimated microscopically on cross sections. RESULTS: The computer-controlled cutting system creates resections of standardized geometry and size with a high reproducibility. An effect level-dependent increase in hemostasis and coagulation depth could be demonstrated with the cutting modes DRY CUT and AUTO CUT using this computer-controlled cutting system. The hemostatic effect with DRY CUT is significantly more pronounced than with AUTO CUT (E1, E3: P < .0001, E6: P = .004), and the coagulation is significantly deeper (E1, E3, E6: P < .0001). CONCLUSIONS: The computer-controlled cutting system creating reproducible resections in combination with the isolated perfused kidney model offers the possibility to systematically investigate bleeding rate and coagulation depth. The stronger hemostatic properties of the DRY CUT mode are more favorable for urologic interventions requiring a higher hemostatic effect than the AUTO CUT mode.


Subject(s)
Blood Coagulation , Electrosurgery/methods , Hemostatic Techniques , Kidney/surgery , Surgery, Computer-Assisted , Humans , In Vitro Techniques
4.
Gastrointest Endosc ; 70(2): 362-8, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19500786

ABSTRACT

BACKGROUND: Argon plasma coagulation (APC) is a monopolar, noncontact, thermal procedure that is widely used in therapeutic endoscopy. Systematic investigations of the tissue damage ex vivo and in vivo with the new, second-generation APC modes are lacking. OBJECTIVE: The aim of this study is to compare the tissue effects of the pulsed effect 2 and precise APC modes. DESIGN AND SETTING: Ex vivo and in vivo animal model. SUBJECTS: This study involved 3 explanted porcine esophagi and 8 pigs under general anesthesia. INTERVENTION: APC application on 3 explanted esophagi and during esophagoscopy. MAIN OUTCOME MEASUREMENTS: The tissue effect was subjected to histological and statistical investigation. RESULTS: In vivo, a well known type of superficial tissue damage (type A) of the tunica mucosa and a new injury pattern (type B) limited to the tunica muscularis, were found. Ex vivo, only type A injuries were seen. Thermal injury of the tunica muscularis was significantly lower with precise APC compared with pulsed APC in vivo. The pulsed effect 2 shows a positive correlation between the penetration depth and the power (r = 0.38, P < .0002) or application time for the highest power setting used (40 W, r = 0.77, P < .0001). This correlation could not be detected with precise APC because of its very superficial tissue effect. LIMITATIONS: This was an animal study. The distance of the APC probe to the esophagus may have varied between applications in vivo. CONCLUSION: Thermal damage by APC of the esophageal tunica muscularis seems to be underestimated ex vivo. The extent of tissue injury was significantly lower with precise APC than with pulsed APC, indicating that precise APC may be suitable for the treatment of particularly thermosensitive, thin-wall anatomy.


Subject(s)
Argon , Burns/pathology , Esophagoscopy , Esophagus/injuries , Esophagus/pathology , Laser Coagulation/adverse effects , Laser Coagulation/methods , Animals , In Vitro Techniques , Swine
5.
Oligonucleotides ; 15(2): 94-104, 2005.
Article in English | MEDLINE | ID: mdl-15989424

ABSTRACT

Here, we provide first evidence that long-term continuous infusion of highly purified antisense phosphorothioate oligodeoxynucleotides (S-ODN) into brain parenchyma is well tolerated and thus highly suitable for in vivo application. AP 12009 is an S-ODN for the therapy of malignant glioma. It is directed against human transforming growth factor-beta (TGF-beta2) mRNA. In the clinical setting, AP 12009 is administered intratumorally by continuous infusion directly into the brain tumor. In view of this clinical application, the focus of our data is on local toxicology studies in rabbits and monkeys to evaluate the safety of AP 12009. AP 12009 was administered either by intrathecal bolus injection into the subarachnoidal space of the lumbar region of both cynomolgus monkeys and rabbits or by continuous intraparenchymatous infusion directly into the brain tissue of rabbits. Intrathecal bolus administration of 0.1 ml of 500 microM AP 12009 showed neither clinical signs of toxicity nor macroscopically visible or histomorphologic changes. After a 7-day intraparenchymatous continuous infusion of 500 microM AP 12009 at 1 microl/h in rabbits, there was no evidence of toxicity except for local mild to moderate lymphocytic leptomeningoencephalitis. Additionally, AP 12009 showed good tolerability in safety pharmacology as well as in acute toxicity studies and 4-week subchronic toxicity studies in mice, rats, and monkeys. This favorable safety profile proves the suitability of AP 12009 for local administration in brain tumor patients from the point of view of toxicology.


Subject(s)
Oligonucleotides, Antisense/administration & dosage , Oligonucleotides, Antisense/toxicity , Thionucleotides/administration & dosage , Thionucleotides/toxicity , Transforming Growth Factor beta/administration & dosage , Transforming Growth Factor beta/toxicity , Animals , Brain Neoplasms/drug therapy , Drug Evaluation, Preclinical , Glioma/drug therapy , Injections, Intraventricular , Injections, Spinal , Macaca fascicularis , Mice , Oligonucleotides, Antisense/genetics , Oligonucleotides, Antisense/therapeutic use , Rabbits , Rats , Rats, Sprague-Dawley , Transforming Growth Factor beta/genetics , Transforming Growth Factor beta2
SELECTION OF CITATIONS
SEARCH DETAIL
...