Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Publication year range
1.
J Clin Med ; 13(10)2024 May 09.
Article in English | MEDLINE | ID: mdl-38792321

ABSTRACT

Background: The usefulness of drug-eluting balloons (DEBs) has not been fully elucidated in calcified coronary lesions (CCLs). This meta-analysis aimed to evaluate the efficacy of DEBs compared to a drug-eluting stent (DES) in this setting. Methods: PubMed, EMBASE and Cochrane were searched through December 2023. The primary endpoint was 12 months major adverse cardiac events (MACE). Secondary endpoints included clinical outcomes and angiographic results after PCI and at a 12-month follow-up. Results: Five studies and a total of 1141 patients with 1176 coronary lesions were included. Overall, the DEB was comparable to DES in MACE (RR = 0.86, 95% CI: 0.62-1.19, p = 0.36), cardiac death (RR = 0.59, 95% CI: 0.23-1.53, p = 0.28), myocardial infarction (RR = 0.89, 95% CI: 0.25-3.24, p = 0.87) and target lesion revascularization (RR = 1.1, 95% CI: 0.68-1.77, p = 0.70). Although the DEB was associated with worse acute angiographic outcomes (acute gain; MD = -0.65, 95% CI: -0.73, -0.56 and minimal lumen diameter; MD = -0.75, 95% CI: -0.89, -0.61), it showed better results at 12 months follow-up (late lumen loss; MD = -0.34, 95% CI: -0.62, -0.07). Conclusions: This meta-analysis showed that the DEB strategy is comparable to DES in the treatment of CCLs in terms of clinical outcomes. Although the DEB strategy had inferior acute angiographic results, it may offer better angiographic results at follow-up.

2.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Article in English | MEDLINE | ID: mdl-38577931

ABSTRACT

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Hemodynamics , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Postoperative Complications , Prospective Studies , Recovery of Function , Risk Factors , Spain , Time Factors , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...