Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Brachytherapy ; 21(2): 208-215, 2022.
Article in English | MEDLINE | ID: mdl-35090830

ABSTRACT

PURPOSE: To accurately quantify local seed displacement from Day 0 to Day 30 for our brachytherapy procedure. To quantify seed loss/migration and to identify the locations from where seeds are missing. METHODS AND MATERIALS: Seed displacements were analyzed in 62 consecutive patients, who received brachytherapy with stranded I-125 seeds. At the start of the procedure, four fiducial gold markers were implanted. At the end of the implantation procedure an in-room 3D CBCT scan (Day 0) was acquired for accurate seed localization. At Day 30 a regular CT scan was acquired. This CT scan was rigidly registered to the CBCT scan using the fiducials. Subsequently, the Hungarian method was used to find pairs of corresponding seeds. Displacements were calculated and missing seeds were identified. RESULTS: Local seed displacements are smaller than 5 mm for 76.3% of the seeds; 2.3% show displacements larger than 10 mm. The largest seed displacements are seen along the inferior-superior axis: on average 1.0 ± 3.2 mm in superior direction with respect to the intraprostatic fiducials. Largest displacements are seen at the inferior-lateral sides of the prostate. On average, the inferior seeds move 1.0 ± 2.8 mm in anterior and 1.8 ± 3.3 mm in superior direction. The percentage of missing seeds is 0.2% (8 out of 3893 seeds for 5 patients). Most of the missing seeds were also originally implanted at the inferior-lateral sides of the prostate. CONCLUSIONS: Local seed displacements and number of missing seeds are small, and predominantly occur around the apex.


Subject(s)
Brachytherapy , Prostatic Neoplasms , Brachytherapy/methods , Humans , Iodine Radioisotopes/therapeutic use , Male , Prostate , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Radiometry/methods , Tomography, X-Ray Computed
2.
Brachytherapy ; 16(3): 572-578, 2017.
Article in English | MEDLINE | ID: mdl-28242194

ABSTRACT

PURPOSE: The quality of permanent prostate brachytherapy can be increased by addition of imaging modalities in the intraoperative procedure. This addition involves image registration, which inherently has inter- and intraobserver variabilities. We sought to quantify the inter- and intraobserver variabilities in geometry and dosimetry for contouring and image registration and analyze the results for our dynamic 125I brachytherapy procedure. METHODS AND MATERIALS: Five observers contoured 11 transrectal ultrasound (TRUS) data sets three times and 11 CT data sets one time. The observers registered 11 TRUS and MRI data sets to cone beam CT (CBCT) using fiducial gold markers. Geometrical and dosimetrical inter- and intraobserver variabilities were assessed. For the contouring study, structures were subdivided into three parts along the craniocaudal axis. RESULTS: We analyzed 165 observations. Interobserver geometrical variability for prostate was 1.1 mm, resulting in a dosimetric variability of 1.6% for V100 and 9.3% for D90. The geometric intraobserver variability was 0.6 mm with a V100 of 0.7% and D90 of 1.1%. TRUS-CBCT registration showed an interobserver variability in V100 of 2.0% and D90 of 3.1%. Intraobserver variabilities were 0.9% and 1.6%, respectively. For MRI-CBCT registration, V100 and D90 were 1.3% and 2.1%. Intraobserver variabilities were 0.7% and 1.1% for the same. CONCLUSIONS: Prostate dosimetry is affected by interobserver contouring and registration variability. The observed variability is smaller than underdosages that are adapted during our dynamic brachytherapy procedure.


Subject(s)
Brachytherapy/methods , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Cone-Beam Computed Tomography , Fiducial Markers , Humans , Iodine Radioisotopes/therapeutic use , Magnetic Resonance Imaging , Male , Observer Variation , Radiotherapy Dosage , Radiotherapy, Image-Guided/methods , Ultrasonography
3.
Med Phys ; 44(4): 1257-1267, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28192614

ABSTRACT

PURPOSE: To evaluate adaptive planning for permanent prostate brachytherapy and to identify the prostate regions that needed adaptation. METHODS AND MATERIALS: After the implantation of stranded seeds, using real-time intraoperative planning, a transrectal ultrasound (TRUS)-scan was obtained and contoured. The positions of seeds were determined on a C-arm cone-beam computed tomography (CBCT)-scan. The CBCT-scan was registered to the TRUS-scan using fiducial gold markers. If dose coverage on the combined image-dataset was inadequate, an intraoperative adaptation was performed by placing remedial seeds. CBCT-based intraoperative dosimetry was analyzed for the prostate (D90, V100, and V150) and the urethra (D30). The effects of the adaptive dosimetry procedure for Day 30 were separately assessed. RESULTS: We analyzed 1266 patients. In 17.4% of the procedures, an adaptation was performed. Without the dose contribution of the adaptation Day 30 V100 would be < 95% for half of this group. On Day 0, the increase due to the adaptation was 11.8 ± 7.2% (1SD) for D90 and 9.0 ± 6.4% for V100. On Day 30, we observed an increase in D90 of 12.3 ± 6.0% and in V100 of 4.2 ± 4.3%. For the total group, a D90 of 119.6 ± 9.1% and V100 of 97.7 ± 2.5% was achieved. Most remedial seeds were placed anteriorly near the base of the prostate. CONCLUSION: CBCT-based adaptive planning enables identification of implants needing adaptation and improves prostate dose coverage. Adaptations were predominantly performed near the anterior base of the prostate.


Subject(s)
Brachytherapy , Cone-Beam Computed Tomography , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Humans , Intraoperative Period , Male , Radiometry , Radiotherapy Dosage
4.
Int J Radiat Oncol Biol Phys ; 96(1): 197-205, 2016 09 01.
Article in English | MEDLINE | ID: mdl-27325474

ABSTRACT

PURPOSE: We sought to identify the intraoperative displacement patterns of seeds and to evaluate the correlation of intraoperative dosimetry with day 30 for permanent prostate brachytherapy. METHODS AND MATERIALS: We analyzed the data from 699 patients. Intraoperative dosimetry was acquired using transrectal ultrasonography (TRUS) and C-arm cone beam computed tomography (CBCT). Intraoperative dosimetry (minimal dose to 40%-95% of the volume [D40-D95]) was compared with the day 30 dosimetry for both modalities. An additional edema-compensating comparison was performed for D90. Stranded seeds were linked between TRUS and CBCT using an automatic and fast linking procedure. Displacement patterns were analyzed for each seed implantation location. RESULTS: On average, an intraoperative (TRUS to CBCT) D90 decline of 10.6% ± 7.4% was observed. Intraoperative CBCT D90 showed a greater correlation (R(2) = 0.33) with respect to Day 30 than did TRUS (R(2) = 0.17). Compensating for edema, the correlation increased to 0.41 for CBCT and 0.38 for TRUS. The mean absolute intraoperative seed displacement was 3.9 ± 2.0 mm. The largest seed displacements were observed near the rectal wall. The central and posterior seeds showed less caudal displacement than lateral and anterior seeds. Seeds that were implanted closer to the base showed more divergence than seeds close to the apex. CONCLUSIONS: Intraoperative CBCT D90 showed a greater correlation with the day 30 dosimetry than intraoperative TRUS. Edema seemed to cause most of the systematic difference between the intraoperative and day 30 dosimetry. Seeds near the rectal wall showed the most displacement, comparing TRUS and CBCT, probably because of TRUS probe-induced prostate deformation.


Subject(s)
Brachytherapy/instrumentation , Edema/etiology , Foreign-Body Migration/etiology , Prostatic Hyperplasia/etiology , Prostatic Neoplasms/radiotherapy , Prosthesis Implantation/adverse effects , Adult , Aged , Brachytherapy/methods , Edema/diagnostic imaging , Foreign-Body Migration/diagnostic imaging , Humans , Intraoperative Care , Male , Middle Aged , Motion , Prostatic Hyperplasia/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Radiometry/methods , Radiotherapy Dosage , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome
6.
Phys Med Biol ; 60(20): N391-403, 2015 Oct 21.
Article in English | MEDLINE | ID: mdl-26439900

ABSTRACT

The geometry of a permanent prostate implant varies over time. Seeds can migrate and edema of the prostate affects the position of seeds. Seed movements directly influence dosimetry which relates to treatment quality. We present a method that tracks all individual seeds over time allowing quantification of seed movements. This linking procedure was tested on transrectal ultrasound (TRUS) and cone-beam CT (CBCT) datasets of 699 patients. These datasets were acquired intraoperatively during a dynamic implantation procedure, that combines both imaging modalities. The procedure was subdivided in four automatic linking steps. (I) The Hungarian Algorithm was applied to initially link seeds in CBCT and the corresponding TRUS datasets. (II) Strands were identified and optimized based on curvature and linefits: non optimal links were removed. (III) The positions of unlinked seeds were reviewed and were linked to incomplete strands if within curvature- and distance-thresholds. (IV) Finally, seeds close to strands were linked, also if the curvature-threshold was violated. After linking the seeds an affine transformation was applied. The procedure was repeated until the results were stable or the 6th iteration ended. All results were visually reviewed for mismatches and uncertainties. Eleven implants showed a mismatch and in 12 cases an uncertainty was identified. On average the linking procedure took 42 ms per case. This accurate and fast method has the potential to be used for other time spans, like Day 30, and other imaging modalities. It can potentially be used during a dynamic implantation procedure to faster and better evaluate the quality of the permanent prostate implant.


Subject(s)
Algorithms , Brachytherapy/methods , Cone-Beam Computed Tomography/methods , Endosonography/methods , Iodine Radioisotopes/therapeutic use , Prostatic Neoplasms/radiotherapy , Prostheses and Implants , Dose-Response Relationship, Radiation , Humans , Male , Prostatic Neoplasms/diagnostic imaging
7.
Herz ; 40(3): 379-85, 2015 May.
Article in German | MEDLINE | ID: mdl-25963171

ABSTRACT

Athletes and especially elite athletes are predominantly young people and are not associated with high health risks, apart from traumatic injuries. Nevertheless, there is a significantly high incidence of sudden cardiac death (SCD), which ranges from 0.6 to 3.0/100,000 athletes per year. Often the SCD is the first manifestation of an underlying cardiac disease. Distinct structural cardiac disorders, such as hypertrophic cardiomyopathy, coronary artery anomalies (17 %), inflammatory disorders (6 %) and arrhythmogenic right ventricular cardiomyopathy as well as conditions without structural cardiac abnormalities, such as primary electrical diseases (channelopathies) are important causes of sudden death. A simple screening can help to identify athletes with these diseases and allow specific therapies or precautionary measures to be initiated.


Subject(s)
Athletes , Cardiovascular Diseases/diagnosis , Death, Sudden, Cardiac/prevention & control , Mandatory Testing/methods , Mass Screening/methods , Sports , Germany , Humans , Physical Examination/methods
8.
Herz ; 39(8): 941-51, 2014 Dec.
Article in German | MEDLINE | ID: mdl-25403982

ABSTRACT

The latest guidelines of the European Society of Cardiology (ESC) on cardiac pacing and cardiac resynchronization therapy were presented and published in June 2013. Compared to the last guidelines from 2007 several substantial changes have been made. The new guidelines are much more clinically oriented with a special focus on practicability. The intention is a better usefulness not only for electrophysiologists but also for cardiologists, internists and general practitioners.


Subject(s)
Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/prevention & control , Cardiac Pacing, Artificial/standards , Cardiology/standards , Diagnostic Techniques, Cardiovascular/standards , Heart Failure/diagnosis , Heart Failure/prevention & control , Europe , Humans
9.
Brachytherapy ; 13(2): 128-36, 2014.
Article in English | MEDLINE | ID: mdl-24041955

ABSTRACT

PURPOSE: To present a high-dose-rate (HDR) brachytherapy procedure for prostate cancer using transrectal ultrasound (TRUS) to contour the regions of interest and registered in-room cone-beam CT (CBCT) images for needle reconstruction. To characterize the registration uncertainties between the two imaging modalities and explore the possibility of performing the procedure solely on TRUS. METHODS AND MATERIALS: Patients were treated with a TRUS/CBCT-based HDR brachytherapy procedure. For 100 patients, dosimetric results were analyzed. For 40 patients, registration uncertainties were examined by determining differences in fiducial marker positions on TRUS and registered CBCT. The accuracy of needle reconstruction on TRUS was investigated by determining the position differences of needle tips on TRUS and CBCT. The dosimetric impact of reregistration and needle reconstruction on TRUS only was studied for 8 patients. RESULTS: The average prostate V100 was 97.8%, urethra D10 was 116.3%, and rectum D1 cc was 66.4% of the prescribed dose. For 85% of the patients, registration inaccuracies were within 3 mm. Large differences were found between needle tips on TRUS and CBCT, especially in cranial-caudal direction, with a maximum of 10.4 mm. Reregistration resulted in a maximum V100 reduction of 0.9%, whereas needle reconstruction on TRUS only gave a maximum reduction of 9.4%. CONCLUSIONS: HDR prostate brachytherapy based on TRUS combined with CBCT is an accurate method. Registration uncertainties, and consequently dosimetric inaccuracies, are small compared with the uncertainties of performing the procedure solely based on static TRUS images. CBCT imaging is a requisite in our current procedure.


Subject(s)
Brachytherapy/methods , Prostatic Neoplasms/radiotherapy , Cone-Beam Computed Tomography , Humans , Male , Needles , Prostatic Neoplasms/diagnostic imaging , Radiometry/methods , Rectum/diagnostic imaging , Rectum/radiation effects , Retrospective Studies , Urethra/diagnostic imaging , Urethra/radiation effects
10.
Brachytherapy ; 11(5): 327-33, 2012.
Article in English | MEDLINE | ID: mdl-21816685

ABSTRACT

PURPOSE: To present an objective automated method to determine time trends in prostatic edema resulting from iodine-125 brachytherapy. METHODS AND MATERIALS: We followed 20 patients, implanted with stranded seeds, with seven consecutive CT scans to establish a time trend in prostate edema. Seed positions were obtained automatically from the CT series. The change in seed positions was used as surrogate for edema. Two approaches were applied to model changes in volume. (1) A cylindrical model: seeds from the compared distribution were linked to the reference distribution of Day 28. After alignment, the compared distribution was scaled in cylindrical coordinates, leading to the changes in radial and craniocaudal directions. The volume changes were calculated using these scaling factors. (2) A spherical model: distances of seeds to the center of gravity of all seeds were used as a measure to model volume changes. RESULTS: With Day 28 as reference, the observed volume changes were smaller than 18% ± 6% (1 standard deviation) for the cylindrical model and 12% ± 7% for the spherical model. One day after implantation, the implanted prostate was less than 10% larger than in the reference scan for both models. Apart from Day 0, both models showed similar volume changes. CONCLUSIONS: We present an objective automated method to determine changes in the implanted prostate volume, eliminating the influence of an observer in the assessment of the prostate size. The implanted volume change was less than 18% ± 7% for the studied group of 20 patients. Edema was 9% ± 5% from 1 day after implantation onward.


Subject(s)
Brachytherapy/adverse effects , Edema/pathology , Models, Theoretical , Prostatic Diseases/pathology , Edema/diagnostic imaging , Humans , Iodine Radioisotopes , Male , Organ Size/radiation effects , Prostatic Diseases/diagnostic imaging , Time Factors , Tomography, X-Ray Computed
11.
Herz ; 36(7): 600-7, 2011 Oct.
Article in German | MEDLINE | ID: mdl-21912910

ABSTRACT

Cardiac contractility modulation (CCM) is a device therapy for patients with systolic heart failure. CCM therapy applies non-excitatory signals during the absolute refractory period of the heart cycle. It influences myocardial contractility by modulating the regulation of calcium cycling. CCM therapy has been proven to enhance peak VO(2), quality of life and exercise tolerance in patients with congestive heart failure. It can be used as an additional therapy to an implantable cardioverter defibrillator (ICD), if present. CCM therapy should be considered in symptomatic patients with congestive heart failure, a left ventricular ejection fraction ≤35% and NYHA class II-III. Atrial fibrillation, high grade arrhythmias and an AV block of more than 300 ms represent contraindications. Patients with a left bundle branch block of >120 ms should be considered for the implantation of a biventricular ICD prior to implantation of a CCM device.


Subject(s)
Heart Failure, Systolic/physiopathology , Heart Failure, Systolic/therapy , Heart Failure/physiopathology , Heart Failure/therapy , Myocardial Contraction/physiology , Pacemaker, Artificial , Software , Contraindications , Double-Blind Method , Electrocardiography/instrumentation , Electrodes, Implanted , Equipment Design , Hemodynamics/physiology , Humans , Randomized Controlled Trials as Topic , Signal Processing, Computer-Assisted/instrumentation , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Left/therapy
12.
Int J Radiat Oncol Biol Phys ; 70(1): 75-82, 2008 Jan 01.
Article in English | MEDLINE | ID: mdl-17869445

ABSTRACT

PURPOSE: To evaluate the first clinical results of an off-line adaptive radiotherapy (ART) protocol for prostate cancer using kilovoltage cone-beam computed tomography (CBCT) in combination with a diet and mild laxatives. METHODS AND MATERIALS: Twenty-three patients began treatment with a planning target volume (PTV) margin of 10 mm. The CBCT scans acquired during the first six fractions were used to generate an average prostate clinical target volume (AV-CTV), and average rectum (AV-Rect). Using these structures, a new treatment plan was generated with a 7-mm PTV margin. Weekly CBCT scans were used to monitor the CTV coverage. A diet and mild laxatives were introduced to improve image quality and reduce prostate motion. RESULTS: Twenty patients were treated with conform ART protocol. For these patients, 91% of the CBCT scans could be used to calculate the AV-CTV and AV-Rect. In 96% of the follow-up CBCT scans, the CTV was located within the average PTV. In the remaining 4%, the prostate extended the PTV by a maximum of 1 mm. Systematic and random errors for organ motion were reduced by a factor of two compared with historical data without diet and laxatives. An average PTV reduction of 29% was achieved. The volume of the AV-Rect that received >65 Gy was reduced by 19%. The mean dose to the anal wall was reduced on average by 4.8 Gy. CONCLUSIONS: We safely reduced the high-dose region by 29%. The reduction in irradiated volume led to a significant reduction in the dose to the rectum. The diet and laxatives improved the image quality and tended to reduce prostate motion.


Subject(s)
Cone-Beam Computed Tomography , Laxatives/administration & dosage , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Aged , Anal Canal/diagnostic imaging , Diet , Gases , Humans , Intestines , Male , Middle Aged , Movement , Prostate/diagnostic imaging , Prostatic Neoplasms/pathology , Radiotherapy/methods , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated , Rectum/diagnostic imaging , Tumor Burden , Urinary Catheterization/instrumentation
13.
Int J Radiat Oncol Biol Phys ; 67(5): 1559-67, 2007 Apr 01.
Article in English | MEDLINE | ID: mdl-17306934

ABSTRACT

PURPOSE: To determine the planning target volume (PTV) margin for an adaptive radiotherapy procedure that uses five computed tomography (CT) scans to calculate an average prostate position and rectum shape. To evaluate alternative methods to determine an average rectum based on a single delineation. METHODS AND MATERIALS: Repeat CT scans (8-13) of 19 patients were used. The contoured prostates of the first four scans were matched on the planning CT (pCT) prostate contours. With the resulting translations and rotations the average prostate position was determined. An average rectum was obtained by either averaging the coordinates of corresponding points on the rectal walls or by selecting the "best" rectum or transforming the pCT rectum. Dose distributions were calculated for various expanded average prostates. The remaining CT scans were used to determine the dose received by prostate and rectum during treatment. RESULTS: For the prostate of the pCT scan and a 10-mm margin, all patients received more than 95% of the prescribed dose to 95% of the prostate. For the average prostate, a margin of 7 mm was needed to obtain a similar result (average PTV reduction 30%). The average rectum overestimated the mean dose to the rectum by 0.4 +/- 1.6 Gy, which was better than the pCT rectum (2.1 +/- 3.0 Gy) and the alternative average rectums (1.0 +/- 2.6 Gy and 1.4 +/- 3.2 Gy). CONCLUSIONS: Our adaptive procedure allows for reduction of the PTV margin to 7 mm without decreasing prostate coverage during treatment. For accurate estimation of the rectum dose, rectums need to be delineated and averaged over multiple scans.


Subject(s)
Prostate/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Rectum/diagnostic imaging , Tomography, X-Ray Computed/methods , Humans , Male , Radiation Injuries/prevention & control , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Rotation
SELECTION OF CITATIONS
SEARCH DETAIL
...