Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
2.
JACC Case Rep ; 6: 101670, 2023 Jan 18.
Article in English | MEDLINE | ID: mdl-36704061

ABSTRACT

Left ventricular outflow tract (LVOT) pseudoaneurysm is a rare condition with a wide range of causes and various clinical outcomes. The causes range from infections, trauma to the chest wall, and iatrogenic origins. We present a unique case of idiopathic LVOT pseudoaneurysm in a patient with no obvious clinical risk factors. (Level of Difficulty: Advanced.).

3.
J Heart Valve Dis ; 26(3): 321-326, 2017 05.
Article in English | MEDLINE | ID: mdl-29092118

ABSTRACT

In patients with carcinoid syndrome, the development of carcinoid valve disease typically carries an unfavorable prognosis. We present the case of a patient with significant valvular dysfunction secondary to carcinoid valve disease. Valve replacement surgery was complicated by the development of prosthetic valve degeneration, ultimately requiring percutaneous valve implantation in a valve-in-valve fashion. The technical details of the case, as well as a review of carcinoid valve disease, including its pathophysiology, clinical manifestations, diagnostic features and management considerations, are presented.


Subject(s)
Carcinoid Heart Disease , Pulmonary Valve Insufficiency , Pulmonary Valve , Tricuspid Valve Insufficiency , Tricuspid Valve , Bioprosthesis , Carcinoid Heart Disease/complications , Carcinoid Heart Disease/diagnostic imaging , Carcinoid Heart Disease/pathology , Carcinoid Heart Disease/surgery , Cardiac Catheterization/instrumentation , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Humans , Middle Aged , Prosthesis Failure , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/pathology , Pulmonary Valve/surgery , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/pathology , Pulmonary Valve Insufficiency/surgery , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/pathology , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/etiology , Tricuspid Valve Insufficiency/pathology , Tricuspid Valve Insufficiency/surgery
5.
J Nucl Med ; 48(8): 1259-65, 2007 Aug.
Article in English | MEDLINE | ID: mdl-17631543

ABSTRACT

UNLABELLED: Filtered backprojection (FBP) is the traditional method for 13N-NH3 PET studies. Ordered-subsets expectation maximization (OSEM) is popular for PET studies because of better noise properties. Scant data exist on the effect of reconstruction algorithms on quantitative myocardial blood flow (MBF) estimation. METHODS: Twenty patients underwent dynamic acquisition rest/stress 13N-NH3 studies. In Part 1, 19 rest/stress image pairs were reconstructed by FBP (10-mm Hanning filter) and by OSEM with 28 subsets and 2 (OSEM2), 6 (OSEM6), or 8 iterations (OSEM8), and a 10-mm postreconstruction smoothing gaussian filter. In Part 2, 9 image pairs were reconstructed by FBP (10-mm Hanning filter) and by OSEM with 28 subsets, 8 iterations, and a gaussian 5-, 10-, or 15-mm postreconstruction smoothing filter. Average MBF (mL/min/mL of myocardium) was calculated using a 3-compartment model. RESULTS: Part 1: For rest MBF, the correlations between FBP and each of the OSEM algorithms were r2 = 0.71, 0.73, and 0.77, respectively. MBF by OSEM6 (0.98 +/- 0.48 [mean +/- SD]) and OSEM8 (0.96 +/- 0.46) was not significantly different from FBP (1.02 +/- 0.39), but OSEM2 (0.80 +/- 0.37) was significantly lower (P < 0.0003). With stress, the correlations were high between FBP and OSEM6 and OSEM8 (r2 = 0.85 and 0.90), and MBF by OSEM6 and OSEM8 was not significantly different from FBP. Part 2: Resting MBF correlated well between FBP and all OSEM smoothing filters (r2 = 0.82, 0.85, and 0.88). Rest MBF using postsmoothing 5- or 10-mm filters was not different from FBP but was significantly lower with the 15-mm filter (P < 0.05). With stress, the correlations were good between FBP and OSEM regardless of smoothing (r2 = 0.76, 0.77, and 0.79). However, MBF with postsmoothing 10- and 15-mm filters was significantly lower than by FBP (P < 0.05). CONCLUSION: Reconstruction algorithms significantly affect the estimation of quantitative blood flow data and should not be assumed to be interchangeable. Although aggressive smoothing may produce visually appealing images with reduced noise levels, it may cause an underestimation of absolute quantitative MBF. In selecting a reconstruction algorithm, an optimal balance between noise properties and diagnostic accuracy must be emphasized.


Subject(s)
Ammonia/metabolism , Coronary Circulation , Image Processing, Computer-Assisted , Nitrogen Radioisotopes , Positron-Emission Tomography/methods , Radiopharmaceuticals , Adolescent , Adult , Aged , Algorithms , Female , Humans , Male , Middle Aged , Observer Variation
SELECTION OF CITATIONS