Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
Thromb Haemost ; 123(7): 723-733, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36944357

ABSTRACT

BACKGROUND: In the INSPIRATION-S trial, atorvastatin versus placebo was associated with a nonsignificant 16% reduction in 30-day composite of venous/arterial thrombosis or death in intensive care unit (ICU) patients with COVID-19. Thrombo-inflammatory response in coronavirus disease 2019 (COVID-19) may last beyond the first 30 days. METHODS: This article reports the effects of atorvastatin 20 mg daily versus placebo on 90-day clinical and functional outcomes from INSPIRATION-S, a double-blind multicenter randomized trial of adult ICU patients with COVID-19. The main outcome for this prespecified study was a composite of adjudicated venous/arterial thrombosis, treatment with extracorporeal membrane oxygenation (ECMO), or all-cause mortality. Functional status was assessed with the Post-COVID-19 Functional Scale. RESULTS: In the primary analysis, 587 patients were included (age: 57 [Q1-Q3: 45-68] years; 44% women). By 90-day follow-up, the main outcome occurred in 96 (33.1%) patients assigned to atorvastatin and 113 (38.0%) assigned to placebo (hazard ratio [HR]: 0.80, 95% confidence interval [CI]: 0.60-1.05, p = 0.11). Atorvastatin in patients who presented within 7 days of symptom onset was associated with reduced 90-day hazard for the main outcome (HR: 0.60, 95% CI: 0.42-0.86, p interaction = 0.02). Atorvastatin use was associated with improved 90-day functional status, although the upper bound CI crossed 1.0 (ORordinal: 0.64, 95% CI: 0.41-1.01, p = 0.05). CONCLUSION: Atorvastatin 20 mg compared with placebo did not significantly reduce the 90-day composite of death, treatment with ECMO, or venous/arterial thrombosis. However, the point estimates do not exclude a potential clinically meaningful treatment effect, especially among patients who presented within 7 days of symptom onset (NCT04486508).


Subject(s)
COVID-19 , Thrombosis , Adult , Humans , Female , Middle Aged , Male , Atorvastatin/therapeutic use , Treatment Outcome , Thrombosis/drug therapy , Intensive Care Units , Double-Blind Method
2.
Phys Med ; 104: 32-42, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36356502

ABSTRACT

PURPOSE: Similar to other radiation therapy techniques, intraoperative electron radiation therapy (IOERT) can benefit from an online treatment planning system (TPS). Among all the analytical electron dose calculation algorithms, pencil beam redefinition algorithm (PBRA) has shown an acceptable accuracy in inhomogeneities. The input dataset for PBRA includes electron planar fluence, mean direction and root mean square (RMS) spread about the mean direction which had been introduced based on the conventional linear accelerator geometry in former studies. Herein, three methods for implementing PBRA for IOERT system are presented. METHODS: The initialization parameters were identified using Monte Carlo (MC) simulation of a dedicated IOERT system equipped with a cylindrical 10 cm applicator, irradiating a water phantom. Phase space distribution of electrons was recorded on a plane below the applicator. The input dataset was extracted for 2 × 2 mm2 pixels and energy bin width of 1 MeV. RESULTS: PBRA was implemented with three initialization methods and compared to MC. The 3D gamma analysis of the algorithm with the Formula method, which was in best agreement with MC in a simple water phantom, showed passing rates of more than 99 % for all nominal energies and it was 97.1 % for 8 MeV in the presence of protecting disk and irregular surface. Implementing PBRA on CUDA C++ resulted in 5 s run time for 8 MeV nominal energy in a water phantom. CONCLUSIONS: The agreement between PBRA dose calculation and MC is promising for the development of an intraoperative TPS for IOERT.


Subject(s)
Electrons , Water
3.
Thromb Haemost ; 122(1): 131-141, 2022 01.
Article in English | MEDLINE | ID: mdl-33865239

ABSTRACT

BACKGROUND: Thrombotic complications are considered among the main extrapulmonary manifestations of coronavirus disease 2019 (COVID-19). The optimal type and duration of prophylactic antithrombotic therapy in these patients remain unknown. METHODS: This article reports the final (90-day) results of the Intermediate versus Standard-dose Prophylactic anticoagulation In cRitically-ill pATIents with COVID-19: An opeN label randomized controlled trial (INSPIRATION) study. Patients with COVID-19 admitted to intensive care were randomized to intermediate-dose versus standard-dose prophylactic anticoagulation for 30 days, irrespective of hospital discharge status. The primary efficacy outcome was a composite of adjudicated venous or arterial thrombosis, treatment with extracorporeal membrane oxygenation (ECMO), or all-cause death. The main safety outcome was major bleeding. RESULTS: Of 600 randomized patients, 562 entered the modified intention-to-treat analysis (median age [Q1, Q3]: 62 [50, 71] years; 237 [42.2%] women), of whom 336 (59.8%) survived to hospital discharge. The primary outcome occurred in 132 (47.8%) of patients assigned to intermediate dose and 130 (45.4%) patients assigned to standard-dose prophylactic anticoagulation (hazard ratio [HR]: 1.21, 95% confidence interval [CI]: 0.95-1.55, p = 0.11). Findings were similar for other efficacy outcomes, and in the landmark analysis from days 31 to 90 (HR: 1.59, 95% CI: 0.45-5.06). There were 7 (2.5%) major bleeding events in the intermediate-dose group (including 3 fatal events) and 4 (1.4%) major bleeding events in the standard-dose group (none fatal) (HR: 1.82, 95% CI: 0.53-6.24). CONCLUSION: Intermediate-dose compared with standard-dose prophylactic anticoagulation did not reduce a composite of death, treatment with ECMO, or venous or arterial thrombosis at 90-day follow-up.


Subject(s)
Anticoagulants/administration & dosage , COVID-19 Drug Treatment , Enoxaparin/administration & dosage , SARS-CoV-2 , Thrombosis/prevention & control , Aged , Anticoagulants/adverse effects , COVID-19/complications , COVID-19/mortality , Cohort Studies , Critical Care , Dose-Response Relationship, Drug , Enoxaparin/adverse effects , Extracorporeal Membrane Oxygenation , Female , Hemorrhage/chemically induced , Humans , Intensive Care Units , Iran/epidemiology , Kaplan-Meier Estimate , Male , Middle Aged , Pandemics , Thrombosis/etiology , Thrombosis/mortality
4.
Eur J Nucl Med Mol Imaging ; 49(5): 1508-1522, 2022 04.
Article in English | MEDLINE | ID: mdl-34778929

ABSTRACT

PURPOSE: This work was set out to investigate the feasibility of dose reduction in SPECT myocardial perfusion imaging (MPI) without sacrificing diagnostic accuracy. A deep learning approach was proposed to synthesize full-dose images from the corresponding low-dose images at different dose reduction levels in the projection space. METHODS: Clinical SPECT-MPI images of 345 patients acquired on a dedicated cardiac SPECT camera in list-mode format were retrospectively employed to predict standard-dose from low-dose images at half-, quarter-, and one-eighth-dose levels. To simulate realistic low-dose projections, 50%, 25%, and 12.5% of the events were randomly selected from the list-mode data through applying binomial subsampling. A generative adversarial network was implemented to predict non-gated standard-dose SPECT images in the projection space at the different dose reduction levels. Well-established metrics, including peak signal-to-noise ratio (PSNR), root mean square error (RMSE), and structural similarity index metrics (SSIM) in addition to Pearson correlation coefficient analysis and clinical parameters derived from Cedars-Sinai software were used to quantitatively assess the predicted standard-dose images. For clinical evaluation, the quality of the predicted standard-dose images was evaluated by a nuclear medicine specialist using a seven-point (- 3 to + 3) grading scheme. RESULTS: The highest PSNR (42.49 ± 2.37) and SSIM (0.99 ± 0.01) and the lowest RMSE (1.99 ± 0.63) were achieved at a half-dose level. Pearson correlation coefficients were 0.997 ± 0.001, 0.994 ± 0.003, and 0.987 ± 0.004 for the predicted standard-dose images at half-, quarter-, and one-eighth-dose levels, respectively. Using the standard-dose images as reference, the Bland-Altman plots sketched for the Cedars-Sinai selected parameters exhibited remarkably less bias and variance in the predicted standard-dose images compared with the low-dose images at all reduced dose levels. Overall, considering the clinical assessment performed by a nuclear medicine specialist, 100%, 80%, and 11% of the predicted standard-dose images were clinically acceptable at half-, quarter-, and one-eighth-dose levels, respectively. CONCLUSION: The noise was effectively suppressed by the proposed network, and the predicted standard-dose images were comparable to reference standard-dose images at half- and quarter-dose levels. However, recovery of the underlying signals/information in low-dose images beyond a quarter of the standard dose would not be feasible (due to very poor signal-to-noise ratio) which will adversely affect the clinical interpretation of the resulting images.


Subject(s)
Deep Learning , Humans , Image Processing, Computer-Assisted/methods , Perfusion , Retrospective Studies , Signal-To-Noise Ratio , Tomography, Emission-Computed, Single-Photon
5.
Med J Islam Repub Iran ; 35: 63, 2021.
Article in English | MEDLINE | ID: mdl-34277500

ABSTRACT

Background: In the pandemic era of Coronavirus disease 19 (COVID-19), one of the most important issues is the nature of real pathological events that occur during disease course in different parts of the body. There are several ways to know more about COVID-related histopathological events,such as tissue sampling which means biopsy from the tissues of either livepeople or necropsy/autopsy of people who died from COVID-19. Methods: We conducted an original study for assessing histopathological findings of lung necropsy samples collected from 15 Iranian patients.The continuous variables were presented as mean and standard deviation, and for the qualitative data on histopathological findings, the percentage or qualitative scores (0 to +3) were used. Results: We found similar presentations of COVID-related histopathologic events regarding percentage and severity in pulmonary tissue, includinglymphocytic infiltrations, inflammatory infiltrations of septal and perivascular areas, desquamated type2 pneumocytes, hyaline membrane changes, fibrin material depositions, abnormal changes of alveolar capillaries, presence of megakaryocytes, PMN infiltrations, septal necrosis, microabscess formation and bacterial colony formation. Also, we found few interesting features which were not completely compatible with previous similar studies or newly reported by ours asa high percentage of anthracosis (86%: 13 patients) that was not clearly reported in other previous studies, also a lower percentage of microthrombotic vascular lung injuries (20%: 3 patients), and a higher percentage of viral cytopathic effects (27%: 4 patients). Conclusion: This article suggests a greater need for evaluatingthe autopsy samples of COVID-19 patients to provide better management strategies and propose the question of whether anthracosismay be a mortality risk factor in COVID-19 patients.

6.
Med Biol Eng Comput ; 59(7-8): 1611-1620, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34268670

ABSTRACT

A new multi-purpose Iranian head and neck (MIHAN) anthropomorphic phantom was designed and manufactured to be used in diagnostic and therapeutic applications. Geometry of MIHAN phantom was determined based on the average dimensions acquired by CT scans of twenty patients without any medical problems in their head and neck site. Because the phantom was expected to be used with different modalities with a wide range of photon energies, attenuation coefficients of some selected materials were determined using Monte Carlo simulation. Based on analytical and simulation results, acrylonitrile butadiene styrene (ABS) and polylactic acid (PLA) were found suitable choices for soft and bony tissues, respectively. They were used in the 3D printer to build the phantom. The suitability of the materials was checked by CT number value comparison between the organs included in the phantom and the corresponding body tissues and also film dosimetry of a typical intensity-modulated radiation therapy (IMRT) plan.. Hounsfield Unit agreement and 95% ± 2% pass rate for the IMRT plan verification proved the suitability of material selection. Also, the film dosimetry showed feasibility of using MIHAN in radiotherapy plan verification workflow. In addition, PLA was introduced as a spongy bone tissue substitute for the first time.


Subject(s)
Head , Radiotherapy, Intensity-Modulated , Head/diagnostic imaging , Humans , Iran , Neck , Phantoms, Imaging , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
7.
JAMA ; 325(16): 1620-1630, 2021 04 27.
Article in English | MEDLINE | ID: mdl-33734299

ABSTRACT

Importance: Thrombotic events are commonly reported in critically ill patients with COVID-19. Limited data exist to guide the intensity of antithrombotic prophylaxis. Objective: To evaluate the effects of intermediate-dose vs standard-dose prophylactic anticoagulation among patients with COVID-19 admitted to the intensive care unit (ICU). Design, Setting, and Participants: Multicenter randomized trial with a 2 × 2 factorial design performed in 10 academic centers in Iran comparing intermediate-dose vs standard-dose prophylactic anticoagulation (first hypothesis) and statin therapy vs matching placebo (second hypothesis; not reported in this article) among adult patients admitted to the ICU with COVID-19. Patients were recruited between July 29, 2020, and November 19, 2020. The final follow-up date for the 30-day primary outcome was December 19, 2020. Interventions: Intermediate-dose (enoxaparin, 1 mg/kg daily) (n = 276) vs standard prophylactic anticoagulation (enoxaparin, 40 mg daily) (n = 286), with modification according to body weight and creatinine clearance. The assigned treatments were planned to be continued until completion of 30-day follow-up. Main Outcomes and Measures: The primary efficacy outcome was a composite of venous or arterial thrombosis, treatment with extracorporeal membrane oxygenation, or mortality within 30 days, assessed in randomized patients who met the eligibility criteria and received at least 1 dose of the assigned treatment. Prespecified safety outcomes included major bleeding according to the Bleeding Academic Research Consortium (type 3 or 5 definition), powered for noninferiority (a noninferiority margin of 1.8 based on odds ratio), and severe thrombocytopenia (platelet count <20 ×103/µL). All outcomes were blindly adjudicated. Results: Among 600 randomized patients, 562 (93.7%) were included in the primary analysis (median [interquartile range] age, 62 [50-71] years; 237 [42.2%] women). The primary efficacy outcome occurred in 126 patients (45.7%) in the intermediate-dose group and 126 patients (44.1%) in the standard-dose prophylaxis group (absolute risk difference, 1.5% [95% CI, -6.6% to 9.8%]; odds ratio, 1.06 [95% CI, 0.76-1.48]; P = .70). Major bleeding occurred in 7 patients (2.5%) in the intermediate-dose group and 4 patients (1.4%) in the standard-dose prophylaxis group (risk difference, 1.1% [1-sided 97.5% CI, -∞ to 3.4%]; odds ratio, 1.83 [1-sided 97.5% CI, 0.00-5.93]), not meeting the noninferiority criteria (P for noninferiority >.99). Severe thrombocytopenia occurred only in patients assigned to the intermediate-dose group (6 vs 0 patients; risk difference, 2.2% [95% CI, 0.4%-3.8%]; P = .01). Conclusions and Relevance: Among patients admitted to the ICU with COVID-19, intermediate-dose prophylactic anticoagulation, compared with standard-dose prophylactic anticoagulation, did not result in a significant difference in the primary outcome of a composite of adjudicated venous or arterial thrombosis, treatment with extracorporeal membrane oxygenation, or mortality within 30 days. These results do not support the routine empirical use of intermediate-dose prophylactic anticoagulation in unselected patients admitted to the ICU with COVID-19. Trial Registration: ClinicalTrials.gov Identifier: NCT04486508.


Subject(s)
Anticoagulants/administration & dosage , COVID-19/complications , Enoxaparin/administration & dosage , Extracorporeal Membrane Oxygenation , Oxygen Inhalation Therapy/methods , Thrombosis/prevention & control , Aged , Anticoagulants/adverse effects , COVID-19/mortality , Drug Administration Schedule , Enoxaparin/adverse effects , Female , Hemorrhage/chemically induced , Hospitalization , Humans , Intensive Care Units , Iran , Length of Stay/statistics & numerical data , Male , Middle Aged , Odds Ratio , Outcome Assessment, Health Care , Pulmonary Embolism/epidemiology , Thrombocytopenia/chemically induced , Thrombosis/etiology , Thrombosis/mortality , Treatment Outcome , Venous Thrombosis/epidemiology , Venous Thrombosis/mortality
8.
Appl Radiat Isot ; 164: 109267, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32819506

ABSTRACT

OBJECTIVES: Detection of urinary stone composition before treatment can help in its management. The purpose of this work is to study the feasibility of classifying the kidney stone compositions in vivo by dual-energy kidney, ureter, and bladder (DEKUB) X-ray imaging. METHODS: Six urinary stone compositions with nine diameters were simulated in a water phantom, and two 70- and 120-kVp images were acquired by radiography tally of the Monte Carlo code. Six image features among 10 were selected for classification of the kidney stones. Four classification algorithms were applied to the dataset using MatLab software. Five-fold cross-validation was applied to the most accurate algorithm for 1000 times and the true and false detection rates were reported. RESULTS: The obtained accuracy of kidney stone classification was 96 ± 2% and this decreased with increasing noise level. The DEKUB was successful in distinguishing brushite, calcium oxalate monohydrate, cystine, and calcium phosphate stones from other types. CONCLUSIONS: Acceptable results achieved by the low-cost, low-dose DEKUB system in detection of kidney stone composition not only obviates a need for complicated imaging systems such as dual-energy computed tomography, but also provides an available and useful aid for physicians to choose between treatment approaches.


Subject(s)
Kidney/diagnostic imaging , Tomography, X-Ray Computed/methods , Ureter/diagnostic imaging , Urinary Bladder/diagnostic imaging , Urinary Calculi/diagnostic imaging , Feasibility Studies , Humans , Phantoms, Imaging , Urinary Calculi/classification
9.
Med Biol Eng Comput ; 58(4): 763-769, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31993886

ABSTRACT

In vivo dosimetry of the patients treated by I-131 is important from patient dosimetry and radiation protection points of view. Knowledge of delivered dose to the target volume and adjacent normal tissues can improve the effectiveness of radioiodine treatment. Herein, design, fabrication, and assessment processes of an iodine radionuclide dosimeter (IRD) are explained. Two CsI(Tl) scintillator crystals coupled to photodiodes were used in IRD fabrication with specifications derived from Monte Carlo (MC) simulation. Linearity, sensitivity, and long-term performance of the system were tested. Delivered dose due to a known administered activity of I-131 was calculated by MC simulation which was validated based on the Medical Internal Radiation Dose (MIRD) Committee formalism, and the calibration factor was provided. Using the current mode signal acquisition method, the system showed a linear response up to 8.2 GBq radioiodine activity to prohibit the pile-up error without a need for correction factor. On the other hand, IRD was sensitive down to the rarely detectable activity of 7.4 MBq. A prototype version of the IRD system has been developed to guide the hospital staff for the safe release of iodine - administered patients and to provide an insight for physicians about the delivered dose to the thyroid and nearby organs. Graphical abstract IRD attached to MIHAN.


Subject(s)
Monitoring, Physiologic/methods , Radiation Dosimeters , Radiometry/instrumentation , Calibration , Humans , Iodine Radioisotopes/analysis , Monitoring, Physiologic/instrumentation , Phantoms, Imaging , Radiometry/methods
10.
Middle East J Dig Dis ; 11(4): 211-217, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31824624

ABSTRACT

BACKGROUND Irritable bowel syndrome (IBS) is the most common chronic gastrointestinal (GI) disorder. Patients with IBS usually suffer from anxiety and depression. A combination of psychological approaches and pharmacological treatments can be a significantly effective treatment for IBS. The main objective of the present study was to provide a therapeutic plan based on laughter yoga and anti-anxiety medication, employed for the very first time, and to determine the effectiveness of these treatments on the anxiety and GI symptoms of patients with IBS. METHODS In this randomized, controlled, clinical trial, the participants were 60 patients selected from those who referred to the GI clinic of Vali-asr Hospital (Birjand, Iran) during the study period (April 2017 to March 2017) and were diagnosed as having IBS based on ROME III criteria. The participants were randomly assigned to either the laughter yoga group, the anti-anxiety medication group, or the symptomatic treatment (control) group. Severity levels of anxiety and GI symptoms before and after intervention were determined and compared among these three groups according to approved protocols. RESULTS The severity of IBS symptoms after the interventions was more greatly reduced in the laughter yoga group than in the anti-anxiety medication and control groups (p = 0.006). The severity of anxiety after interventions decreased in all three groups, especially in the yoga treatment group, but the difference was not statistically significant (p = 0.1). CONCLUSION Laughter yoga is more effective than anti-anxiety medication in reducing the GI symptoms of patients with IBS. Therefore, applying laughter yoga along with common pharmacological therapies for patients with IBS might be strongly advised.

11.
Appl Radiat Isot ; 149: 114-122, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31051437

ABSTRACT

BACKGROUND AND OBJECTIVE: Over the past years, Monte Carlo codes have widespread use in the radiation research field. Radiography tally of MCNPX Monte Carlo code can be a popular and applicable tool for simulation of radiography images. However, validation is the most important prerequisite before using its results. METHODS: Herein, validation of MCNPX radiography tally with experimental results based on the output image parameters has been investigated. Three cubic phantoms with different thicknesses and aluminum, water, and acrylic inserts were studied. The effects of uniformity correction, the detector efficiency of X-ray in different energies, as well as noise caused by a high statistical error in the simulation were also evaluated. RESULTS: Based on the proposed protocol to correct the error and uniformity of simulated images versus experimental ones, the maximum difference of less than 5% was achieved. CONCLUSIONS: Consequently, using the presented method with fewer steps than previous similar works, the MCNPX radiography tally of Monte Carlo code is a useful and validated tool for medical investigation of radiology images.

12.
Eur Radiol ; 29(1): 168-175, 2019 Jan.
Article in English | MEDLINE | ID: mdl-29955947

ABSTRACT

OBJECTIVES: To statistically determine an 'optimum number of CT scanners' for obtaining 'diagnostic reference levels' (DRLs) in CT examinations as close as possible to 'ideal DRLs' when all available CT scanners are considered. METHODS: First, six 'ideal DRLs' (CTDIVol and DLP) were determined for head, chest and abdomen/pelvis examinations by using patient-dose survey data of 100 CT scanners of different models in Tehran. Then, a 'random sampling method' was applied to different percent fractions of patient dose data of 100 CT scanners. The percent differences (PD) of the DRLs obtained from 'ideal DRLs' and their coefficients of variation (CVs) were calculated. The 'optimum number of CT scanners' determined met those of 'ideal DRL' criteria; i.e. precision (CV ≤ 10%) and accuracy (PD ≤ 10%). RESULTS: 'Optimum number of CT scanners' for determining DRLs as close as possible to 'ideal DRLs', fulfilling the stated criteria, is 43 instead of using 100. CONCLUSION: 'Optimum number of CT scanners' for obtaining DRLs as close as possible to 'ideal DRLs' was determined. This optimum number can be effectively applied in patient-dose survey situations with limited resources in a time- and cost-effective manner. KEY POINTS: • Ideal DRLs were determined by a CT patient-dose survey applied to available scanners. • 'Optimum number of CT scanners' statistically determined for DRLs is 43%. • Optimum number can be used for DRLs as if 'ideal DRLs' were determined by all scanners.


Subject(s)
Radiation Dosage , Tomography Scanners, X-Ray Computed/statistics & numerical data , Abdominal Cavity/diagnostic imaging , Head/diagnostic imaging , Humans , Iran , Pelvis/diagnostic imaging , Radiation Protection/standards , Radiation Protection/statistics & numerical data , Radiometry/methods , Radiometry/standards , Reference Values , Surveys and Questionnaires , Thorax/diagnostic imaging , Tomography Scanners, X-Ray Computed/standards , Tomography, X-Ray Computed/instrumentation , Tomography, X-Ray Computed/methods , Tomography, X-Ray Computed/statistics & numerical data
13.
Lasers Med Sci ; 32(9): 2139-2144, 2017 Dec.
Article in English | MEDLINE | ID: mdl-29075996

ABSTRACT

Herein, the performance of single-fiber reflectance spectroscopy (SFRS) in detection of cervical pre-cancerous squamous intraepithelial lesions (SIL) was compared with colposcopy. Based on the previous results obtained from 167 samples and finding the contributing parameters in differentiating SILs from non-SILs, a user-friendly interface was developed to detect the SILs using SFRS system. Detection of SILs in 301 patients was performed by both SFRS system and routine colposcopy. In addition to physician-determined sites, four quarters of the cervix were measured by SFRS system and suspicious lesions detected by either method were biopsied. Histopathologic results of the biopsied species were compared to the physician judgments based on colposcopy and the results of SFRS system. SFRS could differentiate between SILs and non-SILs with mean sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 38.3, 60.9, 15.2, and 84.3%, respectively. These values were obtained as 88.3, 10.6, 15.4, and 83.1% for the colposcopy, respectively. Although sensitivity of SFRS in detection of SILs is about twofold less than the colposcopy, it can reduce the number of unnecessary biopsies by a factor of more than 5.5. Therefore, the aid of SFRS system to the physician can reduce the number of unnecessary biopsies. On the other hand, both colposcopy and SFRS methods equally suffer from low detection worth in terms of positive/negative predictive values. In conclusion, using the online, simple and non-invasive SFRS system to choose between several suspicious sites in a patient in the clinic may be recommended.


Subject(s)
Colposcopy , Spectrum Analysis/methods , Adult , Algorithms , Female , Humans , User-Computer Interface , Uterine Cervical Neoplasms/diagnosis , Uterine Cervical Dysplasia/diagnosis
14.
Iran J Microbiol ; 8(6): 377-382, 2016 Dec.
Article in English | MEDLINE | ID: mdl-28491248

ABSTRACT

BACKGROUND AND OBJECTIVES: Phosphorus is one of the low bioavailable macroelements. Use of microorganisms in biofertilizers could release phosphorus from insoluble compounds. Pseudomonas putida P13 and Pantoea agglomerans P5 are well recognized for application as phosphate solubilizing bioinoculants and are used as solid carrier based. Liquid bioinoculants are preferred for economizing production process and longer shelf-life. MATERIALS AND METHODS: Five low cost liquid formulations were examined. Formulations 1, 2 and 3, were phosphate buffer, 0.2% and 0.5% KNO3 dissolved in phosphate buffer, respectively. Formulation 4 was nutrient broth containing 4% glycerol and formulation 5 was diluted nutrient broth containing 4% glycerol. Survival (cfu) and phosphate solubilization index (SI) were evaluated after 3 months. RESULTS: Considering strain P5, increase in KNO3 concentration decreased preserving ability. While using KNO3 at 0.2% was accompanied with reaching maximum SI level. Overall, less nutritious formulations (1 and 5) provided maximum preserving ability without bioactivity loss. In the case of strain P13, maximum survival obtained in formulations 2 and 3, whereas SI level decreased. Preserving ability in formulations 1, 4 and 5 was similar but less nutritious formulations (1 and 5), improved bioactivity. CONCLUSION: The results introduced two formulations of 1 and 5 as economically efficient liquid bioinoculants for Pseudomonas putida and Pantoea agglomerans.

15.
J Lasers Med Sci ; 7(4): 233-237, 2016.
Article in English | MEDLINE | ID: mdl-28491258

ABSTRACT

Introduction: Single fiber reflectance spectroscopy (SFRS) is a noninvasive procedure to quantitate tissue absorption and scattering properties. It can be used to diagnose different diseases such as malignancy and pre-cancerous conditions. The measurement is done with a fiber optic probe in contact with the tissue surface. Herein, the effect of probe pressure on the extracted parameters from human lip spectra was studied. Methods: Thirty-three normal subjects were examined with three exerted pressure levels on the right, middle and left parts of their lips. Results: The results showed variation of spectroscopic parameters with different pressure levels. However, the effect was seen between a very mild contact (pressure 1) and the other reasonably practical pressure levels normally used in the medical centers. Conclusion: SFRS can be used as a reliable diagnostic tool in clinics.

16.
Arch Iran Med ; 17(9): 602-7, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25204475

ABSTRACT

BACKGROUND: We assessed the performance of single fiber reflectance spectroscopy (SFRS) in discriminating cervical squamous intraepithelial lesions (SIL) from non-SILs and the probable influence of environmental factors on its performance. METHODS: SFRS was used to measure the reflected light from cervical tissue of 157 patients undergoing standard colposcopy. Seven parameters extracted from the spectra in addition to two biographic parameters were used to compare the biopsy-confirmed SILs with non-SILs. The tissue classification capability was reported by receiver operating characteristic (ROC) curves. In addition, the effect of five interfering parameters, including the probe, clinician, hospital, menopausal status and age of the patient on spectroscopic parameters were investigated by the Kruskal-wallis test. RESULTS: The average vessel diameter and beta-carotene concentration were found to be the parameters contributing to tissue discrimination. SFRS could differentiate between SILs and non-SILs with sensitivity, specificity and area under the ROC curve of 63% ± 6%, 68% ± 6% and 0.69 ± 0.04, respectively. None of the five environmental parameters interfered with the discriminator spectroscopic parameters. CONCLUSIONS: SFRS was found as a noninvasive, fast, compact, cost-effective, independent, and acceptably accurate system to help the clinician to reduce the number of unnecessary biopsies during the colposcopy procedure.


Subject(s)
Optical Imaging/methods , Precancerous Conditions/diagnosis , Spectrum Analysis/methods , Uterine Cervical Neoplasms/diagnosis , Adult , Age Factors , Cervix Uteri/pathology , Female , Humans , Precancerous Conditions/pathology , Uterine Cervical Neoplasms/pathology
17.
Lasers Med Sci ; 29(2): 831-45, 2014 Mar.
Article in English | MEDLINE | ID: mdl-23467754

ABSTRACT

In order to investigate the effectiveness of optical spectroscopy for in vivo diagnosis of cervical pre-cancerous conditions, a series of published studies are surveyed. The six optical technologies investigated include fluorescence spectroscopy, reflectance spectroscopy, and their combination using point probe or multispectral imaging approaches. Searching in the well-known databases, the most recent published works were sought out. Various aspects of the studies were evaluated including the details of the technology used, the pathologic threshold for tissue classification and the gold standard, the study population and prevalence of disease in this population, the method of measurement, the number of clinicians involved in the study, the classification and validation algorithms, and the performance in terms of sensitivity, specificity and, when available, the area under the receiver operating characteristic curve. Forty-four studies conducted from 1994 to 2012 were evaluated. The data are gathered in two comprehensive tables, and five illustrations are provided to simplify a comparison between studies from different points of view. There is a broad band of studies from small pilot studies through phase III clinical trials. Among the reviewed articles, only three factors were found to influence the performance of the optical spectroscopy studies. Multispectral approaches show higher specificity than the point probe approaches (p = 0.001). The use of acetic acid before measurement and prevalence of disease among the studied population, also, have an impact on the sensitivity and specificity of the studies (p < 0.05), respectively.


Subject(s)
Optics and Photonics/methods , Precancerous Conditions/pathology , Spectrum Analysis/methods , Uterine Cervical Neoplasms/pathology , Algorithms , Female , Humans , Precancerous Conditions/diagnosis , Sample Size , Sensitivity and Specificity , Spectrometry, Fluorescence/methods , Uterine Cervical Neoplasms/diagnosis
18.
J Biomed Opt ; 18(1): 17002, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23292613

ABSTRACT

We have assessed the value of single fiber reflectance (SFR) spectroscopy in prediction of cervical squamous intraepithelial lesions (SIL). SFR was used to measure reflected light from 32 patients undergoing standard colposcopy. Seven parameters extracted from the spectra in addition to two biographic parameters were compared in biopsy-confirmed SIL versus nonSIL. The significant parameters in the model were determined using stepwise logistic regression. The classification performance was evaluated by a leave-one-out cross-validation method and reported by receiver operating characteristic (ROC) curves. Light absorption properties and biographic characteristics of the patient contributed significantly to the accuracy of the model. Combining important parameters, the best retrospective sensitivity, specificity and area under the ROC curve for SIL sites versus nonSIL were 89%, 80% and 0.89%, respectively. SFR spectroscopy shows promise as a noninvasive, real-time method to guide the clinician in reducing the number of unnecessary biopsies. Discrimination of SIL from other abnormalities compares favorably with that obtained by fluorescence alone and by fluorescence combined with reflectance spectroscopy while the simplicity and low cost of the presented system are dominant.


Subject(s)
Optical Imaging/methods , Precancerous Conditions/pathology , Spectrum Analysis/methods , Uterine Cervical Dysplasia/pathology , Uterine Cervical Neoplasms/pathology , Adult , Female , Humans , Image Interpretation, Computer-Assisted , Middle Aged , Precancerous Conditions/chemistry , ROC Curve , Sensitivity and Specificity , Statistics, Nonparametric , Uterine Cervical Neoplasms/chemistry , Uterine Cervical Dysplasia/chemistry
19.
Iran J Microbiol ; 5(4): 356-65, 2013 Dec.
Article in English | MEDLINE | ID: mdl-25848505

ABSTRACT

BACKGROUND AND OBJECTIVES: Annual incidence of infection with S. Typhi is estimated to be about 17 million cases worldwide. A systematic search among actinomycete isolates from soil of Iran aimed at finding active actinomycetes against the causative agent of typhoid fever, Salmonella Typhi was carried out during this study. MATERIALS AND METHODS: Our anti-Salmonella screening program resulted in nine highly active actinomycete isolates. All nine antibiotic producing strains showed broad-spectrum antibacterial activity, as five strains showed antifungal activity as well. Based on microscopic morphology and cell wall analysis, all nine active actinomycete strains were representatives of the genus Streptomyces. Three of the producing strains including the isolates HG87, HG116 and HG443 with inhibition zone of >20 mm, were selected for further identification and investigation of cytotoxic effects. RESULTS AND CONCLUSION: None of the producing strains showed cytotoxicity on HEK and USSC cell lines, while strain HG116 showed excellent antitumor activity on T47D cancer cell lines. Isolates HG87, HG116 and HG443 can be distinguished from the related species by some phenotypic and biochemical characteristics. Our results demonstrate the broad-range biological activity exhibited by bioactive compounds of soil actinomycetes from Iran.

20.
Phys Med ; 28(2): 153-60, 2012 Apr.
Article in English | MEDLINE | ID: mdl-21624844

ABSTRACT

Cobalt 60 source is generally available on high dose rate (HDR) afterloading equipment especially for treatment of gynecological lesions. The GZP6 remote afterloader (Nuclear Power Institute of China) utilizes (60)Co sources for treatment of intracavitary and intraluminal malignancies. In this study, the AAPM TG-43 dosimetric parameters of three sources in GZP6 system have been studied using MCNP4C Monte Carlo (MC) code; and the results are compared with other available (60)Co HDR sources. The presented parameters consist of air kerma strength, dose rate constant, radial dose function and anisotropy function. They show less than 1% uncertainty. The TG-43 based dosimetry data can be used not only to validate the dedicated treatment planning software (TPS), but also to introduce new complementary software to enhance the system performance in gynecological treatments.


Subject(s)
Monte Carlo Method , Radiation Dosage , Radiotherapy Planning, Computer-Assisted/methods , Anisotropy , Cobalt Radioisotopes/therapeutic use , Radiometry , Radiotherapy Dosage , Software , Uncertainty
SELECTION OF CITATIONS
SEARCH DETAIL
...