Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Radiol Case Rep ; 19(3): 890-894, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38188956

ABSTRACT

We report a case of a 40-year-old female with a solitary plasmacytoma of the right transverse apophysis of C1 who underwent combined transoral ablation using a curved steerable needle and cementoplasty under CBCT and infra-red augmented reality navigation system. An imaging work-up revealed an osteolytic lesion determining partial collapse of the right lateral mass of C1 and involving the vertebral foramen. After a biopsy, that revealed a solid tissue consistent with plasmacytoma, it was decided to proceed with radiation therapy. Subsequent PET-CT restaging scans showed residual tumors treated with a transoral percutaneous approach, combining ablation and cementoplasty. This report evaluates the benefits of this combined procedure and the transoral approach, focusing on the advantages of steerable devices and navigation systems.

2.
Case Rep Otolaryngol ; 2023: 1351982, 2023.
Article in English | MEDLINE | ID: mdl-37181231

ABSTRACT

Background: Juvenile nasopharyngeal angiofibroma (JNA) is a rare tumor that mainly affects young boys. Its intervention may be complex due to its high vascularity, location, and extension. Preoperative embolization is used to prevent intrasurgical and postsurgical bleeding. Two main kinds of embolization are described in literature: intratumoral and transarterial, and numerous embolic materials are used. Case Presentation. We want to present a case of presurgical embolization of a stage IV JNA, performed using a single stop-flow balloon assisted technique with the balloon cuffed exclusively in the external carotid artery and using Onyx 18 as an embolic agent. Conclusions: The embolization with an exclusive external carotid artery single stop-flow technique using Onyx 18 is a safe, effective, and a definitive approach.

3.
J Vasc Access ; 21(5): 673-679, 2020 Sep.
Article in English | MEDLINE | ID: mdl-31928304

ABSTRACT

PURPOSE: To present a selected series of extensively occlusive thrombosis of arteriovenous graft treated with the Penumbra's Indigo System. MATERIALS AND METHODS: Ten patients with acute (within 72 h) extensively occlusive thrombosis of arteriovenous graft (mean extension = 30.1 (range = 15-45) cm) were treated at our institution with the Indigo System. Of the 10 cases, thrombosis was extended to venous outflow in 7 cases and to both arterial inflow and venous outflow in 3 cases. RESULTS: Both anatomic and clinical success were achieved in 8 of the 10 procedures (80.0%). In the 2 cases of technical failure, the patients underwent surgical thrombectomy with the finding of arteriovenous graft exhaustion, which was then replaced. The 6-month primary patency, primary-assisted patency, and secondary patency rates were 37.5% (3/8), 50.0% (4/8), and 62.5% (5/8). We reported 2 complications (one minor and one major adverse event). CONCLUSION: Percutaneous mechanical thrombectomy aspiration with Indigo System is a relatively safe and effective procedure and can be used even in extensively thrombosed arteriovenous graft.


Subject(s)
Arteriovenous Shunt, Surgical/adverse effects , Graft Occlusion, Vascular/therapy , Renal Dialysis , Thrombectomy/instrumentation , Thrombosis/therapy , Adult , Aged , Aged, 80 and over , Female , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Humans , Male , Middle Aged , Retrospective Studies , Suction , Thrombectomy/adverse effects , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/physiopathology , Time Factors , Treatment Outcome , Vacuum , Vascular Patency
4.
Vasc Endovascular Surg ; 54(1): 25-35, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31537181

ABSTRACT

PURPOSE: The aim of this study is to present our personal experience using covered nitinol stent-graft in the treatment of outflow tract stenosis of arteriovenous grafts (AVGs) for hemodialysis access. MATERIALS AND METHODS: Between May 2015 and October 2017, we retrospectively evaluated 36 (24 males, 12 females; mean age: 65.6 years) patients with AVGs on hemodialysis who underwent percutaneous angioplasty followed by endovascular stent-graft deployment for the treatment of stenosis of the venous outflow of the AVG. Indication for treatment included early restenosis (<3 months after previous percutaneous transluminal angioplasty [PTA]), long stenosis (stenoses >50% extending for a length >5 cm), and recoil of the stenosis after PTA performed with a noncompliant high-pressure balloon. Of 36 patients, 27 (75%) required surgical thrombectomy prior to endovascular procedure. Technical success, clinical success, primary and secondary patency, and safety were evaluated. RESULTS: Technical success was 100%, and clinical success was 94.4%. Primary patency was 94.4%, 72.2%, 63%, 45.9%, and 45.9% at 1, 3, 6, 12, and 18 months (average: 215 days, range: 9-653 days); secondary patency was 94.4% and 86.1% at 1 and 3 months; 80.4% at 6, 12, and 18 months; and 53.6% at 24 months (average: 276.8 days, range: 9-744 days). No deaths were registered. CONCLUSIONS: In selected cases, the use of stent-graft represents an effective and safe solution for the treatment of stenotic complications of the venous outflow of AVGs, even in the setting of access thrombosis.


Subject(s)
Arteriovenous Shunt, Surgical/instrumentation , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Graft Occlusion, Vascular/surgery , Renal Dialysis , Stents , Adult , Aged , Aged, 80 and over , Alloys , Arteriovenous Shunt, Surgical/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Female , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/physiopathology , Humans , Male , Middle Aged , Polytetrafluoroethylene , Prosthesis Design , Reoperation , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome , Vascular Patency
5.
Pol J Radiol ; 83: e600-e609, 2018.
Article in English | MEDLINE | ID: mdl-30800199

ABSTRACT

PURPOSE: To assess the diagnostic performance of diffusion-weighted imaging (DWI) for the discrimination of complete responder (CR) from the non-complete responder (n-CR) in patients with locally advanced rectal cancer (LARC) undergoing chemotherapy and radiation (CRT). MATERIAL AND METHODS: Between December 2009 and January 2014, 32 patients (33 lesions: one patient had two synchronous lesions) were enrolled in this retrospective study. All patients underwent a pre- and post-CRT conventional MRI study completed with DWI. For both data sets (T2-weighted and DWI), the pre- and post-CRT tumour volume (VT2; VDWI) and the tumour volume reduction ratio (ΔV%) were determined as well as pre- and post-CRT apparent diffusion coefficient (ADC) and ADC change (ΔADC%). Histopathological findings were the standard of reference. Receiver operating characteristic (ROC) curves were generated to compare performance of T2-weighted and DWI volumetry, as well as ADC. RESULTS: The area under the ROC curve (AUC) revealed a good accuracy of pre- and post-CRT values of VT2 (0.86; 0.91) and VDWI (0.82; 1.00) as well as those of ΔVT2% (0.84) and ΔVDWI% (1.00) for the CR assessment, with no statistical difference. The AUC of pre- and post-CRT ADC (0.53; 0.54) and that of ΔADC% (0.58) were significantly lower. CONCLUSIONS: Both post-CRT VDWI and ΔVDWI% (AUC = 1) are very accurate for the assessment of the CR, in spite of no significant differences in comparison to the conventional post-CRT VT2 (AUC = 0.91) and ΔVT2% (AUC = 0.84). On the contrary, both ADC and ΔADC% values are not reliable.

6.
Sleep Breath ; 20(4): 1245-1253, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27136936

ABSTRACT

PURPOSE: The aim of our study was to apply the electrical impedance tomography (EIT) technique to the study of ventilation during wake and NREM and REM sleep in patients with obstructive sleep apneas (OSA). METHODS: This is a prospective, observational, monocentric, pilot study in a neurology department with a sleep disorder center. Inclusion criteria were age ≥18 years, both gender, and diagnosis of OSA. Exclusion criteria were the contraindications to the thoracic EIT. All patients underwent laboratory-based polysomnography (PSG) alongside thoracic EIT. Primary endpoint was to compare the global impedance (GI) among the conditions: "Wake" vs "Sleep," "NREM" vs "REM," and "OSA" vs "Non-OSA." Secondary endpoint was to measure the regional distribution of impedance in the four regions of interest (ROIs), in each condition. RESULTS: Of the 17 consecutive patients enrolled, two were excluded because of poor-quality EIT tracings. Fifteen were analyzed, 10 men and 5 women, mean age 51.6 ± 14.4 years. GI was higher in Wake vs Sleep (Wake 13.24 ± 11.23; Sleep 12.56 ± 13.36; p < 0.01), in NREM vs REM (NREM 13.48 ± 13.43; REM 0.59 ± 0.01; p < 0.01), and in Non-OSA vs OSA (Non-OSA 10.50 ± 12.99; OSA 18.98 ± 10.06; p < 0.01). No significant differences were observed in the regional distribution of impedance between Wake and Sleep (χ 2 = 3.66; p = 0.299) and between Non-OSA and OSA (χ 2 = 1.00; p = 0.799); conversely, a significant difference was observed between NREM and REM sleep (χ 2 = 62.94; p < 0.001). CONCLUSIONS: To our knowledge, this is the first study that addresses the issue of regional ventilation in OSA patients during sleep. Thoracic electrical impedance changes through the sleep-wake cycle and during obstructive events. The application of thoracic EIT can prove a valuable additional strategy for the evaluation of OSA patients.


Subject(s)
Electric Impedance , Polysomnography , Pulmonary Ventilation/physiology , Sleep Apnea, Obstructive/physiopathology , Sleep Stages/physiology , Tomography/methods , Adult , Aged , Female , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Reference Values , Thorax/physiopathology , Tomography/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...