Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Clin Radiol ; 74(12): 974.e1-974.e6, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31521327

ABSTRACT

AIM: To compare a standard intra-operative mammography (IM) device with digital breast tomosynthesis using a dedicated device (Mozart system) in the evaluation of surgical margins at first excision. MATERIALS AND METHODS: The study received institutional review board approval and written informed consent was obtained from participants. From January 2018 to December 2018, a prospective analysis of the images of IM device and intra-operative digital breast tomosynthesis with a dedicated device (Mozart system) in n=89 breast cancer patients (average patients age: 58 years, age range: 35-76 years) was undertaken. Images were evaluated by two expert breast radiologists independently of each other and blinded to each other's interpretation, who indicated the positive cases requiring surgical re-excision intra-operatively. RESULTS: Mean cancer size was 12.5±4.5 mm. Radiological signs of the lesions were microcalcifications (n=71), nodules (n=10), and architectural distortions (n=8). A total of 20/89 (17%) patients underwent intra-operative re-excision for positive margins. Intra-operative digital breast tomosynthesis with a dedicated device and IM showed discrepancies in 15/89 cases (17%). Mozart system results informed the necessity to perform a re-excision (n=15). Overall, receiver operating characteristic (ROC) curve analysis showed and area under the ROC curve (AUC) of 0.82 for the Mozart system versus 0.65 for IM. ROC analysis of radiological findings with microcalcifications showed an AUC of 0.92 for the Mozart system versus 0.74 for IM, whereas AUC in cases with no microcalcifications were 0.87 and 0.75, respectively. CONCLUSION: Intra-operative digital breast tomosynthesis with a dedicated device provides more information (better accuracy) than IM and facilitated a reduction in re-excision rates.


Subject(s)
Breast Neoplasms/diagnostic imaging , Mammography , Margins of Excision , Adult , Aged , Breast Neoplasms/pathology , Breast Neoplasms/surgery , Calcinosis/diagnostic imaging , Female , Humans , Intraoperative Period , Mammography/methods , Mastectomy, Segmental/methods , Middle Aged
2.
J Fish Biol ; 91(4): 1062-1071, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28901006

ABSTRACT

The maturity and reproduction of the Atlantic angel shark Squatina dumeril were assessed using 77 females (29·2-110·4 cm total length; LT ) and 269 males (58·7-108·2 cm LT ) harvested by artisanal gillnetters off Venezuela. The biased sex ratio implied segregation or sex-specific gear selectivity. Based on the development of the reproductive tract, 50% LT at sexual maturity (LT50 , mean ± s.e.) for females and males were estimated at 86·14 ± 0·64 and 81·55 ± 0·12 cm, respectively. Uterine fecundity ranged between one and six and with a maximum embryo size of 25·7 cm LT . Gravid females were observed from August to December, including those close to parturition and while the gestation period was not confirmed, the size of ovarian follicles among some specimens implied protraction. The low fecundity of the species supports close monitoring of catches.


Subject(s)
Reproduction , Sharks/physiology , Animals , Caribbean Region , Conservation of Natural Resources , Female , Fertility , Male , Ovarian Follicle/anatomy & histology , Population Density , Sex Ratio , Sharks/growth & development , Venezuela
4.
Musculoskelet Surg ; 100(3): 231-238, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27628912

ABSTRACT

PURPOSE: The aim of this study was to compare the accuracy of clinical examination to that of MRI evaluated by two independent radiologists for the diagnosis of meniscal tears and chronic anterior cruciate ligament injuries and to assess the MRI accuracy in the diagnosis of cartilage defects. METHODS: Seventy-six consecutive patients with suspected intra-articular knee pathology were prospectively evaluated by objective examination, 1.5 T MRI, re-examined by trained radiologist and arthroscopy. Accuracy, sensitivity, specificity, positive predictive value and negative predictive value were calculated. Agreement analysis with kappa (К) coefficient values was performed for meniscal and ACL tears. RESULTS: No differences were found between diagnostic accuracy of clinical examination, the first and second MRI reports in diagnosis of medial meniscus (84 vs 96 vs 97 %) and anterior cruciate ligament injuries (93 vs 78 vs 89 %). For the lateral meniscal tears, the accuracy of the second radiologist was significantly higher than those of the first (96 vs 75 %; p < 0.01) and clinical examination (96 vs 86 %; p = 0.02). High diagnostic values were obtained for the diagnosis of full-thickness chondral defects with sensitivity of 100 %, specificity of 95 % and accuracy of 95 %. CONCLUSION: Clinical and MRI evaluations have no differences in the diagnosis of medial meniscus and anterior cruciate ligament injuries. A trained radiologist obtained better sensitivity, specificity and accuracy in the diagnosis of lateral meniscus. 1.5 T MRI does not represent the technique of choice in the evaluation of chondral defect but demonstrated high diagnostic accuracy for detection of full-thickness chondral defects. LEVEL OF EVIDENCE: Diagnostic prospective study, Level II.


Subject(s)
Anterior Cruciate Ligament Injuries/diagnosis , Arthroscopy , Knee Injuries/diagnosis , Magnetic Resonance Imaging , Physical Examination , Tibial Meniscus Injuries/diagnosis , Adult , Anterior Cruciate Ligament Injuries/diagnostic imaging , Anterior Cruciate Ligament Injuries/surgery , Arthroscopy/methods , Cartilage, Articular/injuries , Chronic Disease , Female , Humans , Knee Injuries/diagnostic imaging , Knee Injuries/surgery , Magnetic Resonance Imaging/methods , Male , Physical Examination/methods , Predictive Value of Tests , Prospective Studies , Risk Assessment , Sensitivity and Specificity , Tibial Meniscus Injuries/diagnostic imaging , Tibial Meniscus Injuries/surgery , Treatment Outcome
6.
Ultraschall Med ; 36(6): 618-22, 2015 Dec.
Article in English | MEDLINE | ID: mdl-25734410

ABSTRACT

PURPOSE: The objectives of this study were to compare sonoelastographic color findings of the perineural area between carpal tunnel syndrome patients and healthy volunteers, and to analyze elastographic findings in that area before and immediately after intracarpal tunnel injection in carpal tunnel syndrome patients. MATERIALS AND METHODS: We studied both hands of 15 healthy volunteers (7 men, 8 women; mean age: 60.1 years, range: 41 - 88 years) and 72 hands from 70 patients with symptomatic carpal tunnel syndrome (24 men, 46 women; mean age: 54.2 years, range: 24 - 83 years). Sonoelastographic color distribution was assessed in the perineural area between the median nerve and adjacent flexor tendons. The color elastograms were graded using the following system: Grade 1 as red (softest), grade 2 as yellow (soft), grade 3 as green (hard), grade 4 as blue (hardest). The patients were treated with corticosteroid injection and were reassessed with sonoelastography immediately after the injection. RESULTS: The median color grading in the perineural area of carpal tunnel syndrome patients was grade 3 (3.1 ±â€Š0.3, mean ±â€Š95 % Cl), which was stiffer than that of healthy volunteers (grade 1, 1.9 ±â€Š0.4) (p < 0.0001). Immediately after injection, the diffusion of the injected fluid was observed as having a softer appearance (grade 1, 1.4 ±â€Š0.2) (p < 0.0001). CONCLUSION: The perineural area surrounding the median nerve in carpal tunnel syndrome patients was stiffer than that in healthy volunteers. Diffusion of the injected fluid in the carpal tunnel was seen as a softer finding after injection in real time using sonoelastography.


Subject(s)
Carpal Tunnel Syndrome/diagnostic imaging , Carpal Tunnel Syndrome/drug therapy , Elasticity Imaging Techniques/methods , Image Enhancement/methods , Median Nerve/drug effects , Median Nerve/diagnostic imaging , Mepivacaine/administration & dosage , Triamcinolone Acetonide/administration & dosage , Adult , Aged , Aged, 80 and over , Case-Control Studies , Female , Humans , Injections, Intra-Articular , Male , Middle Aged , Observer Variation , Reference Values
8.
Br J Radiol ; 86(1031): 20130255, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24029631

ABSTRACT

OBJECTIVE: To compare breast density estimated from two-dimensional full-field digital mammography (2D FFDM) and from digital breast tomosynthesis (DBT) according to different Breast Imaging-Reporting and Data System (BI-RADS) categories, using automated software. METHODS: Institutional review board approval and written informed patient consent were obtained. DBT and 2D FFDM were performed in the same patients to allow within-patient comparison. A total of 160 consecutive patients (mean age: 50±14 years; mean body mass index: 22±3) were included to create paired data sets of 40 patients for each BI-RADS category. Automatic software (MedDensity(©), developed by Giulio Tagliafico) was used to compare the percentage breast density between DBT and 2D FFDM. The estimated breast percentage density obtained using DBT and 2D FFDM was examined for correlation with the radiologists' visual BI-RADS density classification. RESULTS: The 2D FFDM differed from DBT by 16.0% in BI-RADS Category 1, by 11.9% in Category 2, by 3.5% in Category 3 and by 18.1% in Category 4. These differences were highly significant (p<0.0001). There was a good correlation between the BI-RADS categories and the density evaluated using 2D FFDM and DBT (r=0.56, p<0.01 and r=0.48, p<0.01, respectively). CONCLUSION: Using DBT, breast density values were lower than those obtained using 2D FFDM, with a non-linear relationship across the BI-RADS categories. These data are relevant for clinical practice and research studies using density in determining the risk. ADVANCES IN KNOWLEDGE: On DBT, breast density values were lower than with 2D FFDM, with a non-linear relationship across the classical BI-RADS categories.


Subject(s)
Breast Neoplasms/diagnostic imaging , Mammography/methods , Radiographic Image Enhancement/methods , Breast/cytology , Breast/pathology , Early Detection of Cancer/methods , Female , Humans , Middle Aged , Software , Tomography, X-Ray
9.
Br J Radiol ; 86(1025): 20130004, 2013 May.
Article in English | MEDLINE | ID: mdl-23420050

ABSTRACT

OBJECTIVE: To demonstrate normal and abnormal findings of distal brachialis tendon attachment in cadavers, normal volunteers and patients by means of ultrasound. METHODS: 3 cadaveric specimens, 30 normal volunteers and 125 patients were evaluated by means of ultrasound. Correlative MRI was obtained in volunteers. RESULTS: In all cases, ultrasound demonstrated the distal brachialis tendon shaped by two distinct tendons belonging to the deep head and superficial head of the brachialis muscle. Correlative MRI demonstrated that the brachialis is composed of two distinct tendons in 83% of volunteers (25/30). In the patient group, four avulsions with bony detachment involving the deep head, one delayed onset muscular soreness and three tendinous detachments with no bony avulsion involving one or two tendons were identified. The four patients with bony avulsion were immediately referred to the orthopaedic surgeon for a pre-surgical evaluation. Patients without bony avulsion were not referred to the surgeon. CONCLUSION: Detailed anatomy of the distal tendon is discernible in 100% of cases with ultrasound. There are two distinct tendons, and ultrasound can differentiate isolated lesions. In patients with distal brachialis tendon lesions, ultrasound may modify the clinical management of the patient. Advances in knowledge Detailed anatomy of the distal brachialis tendon is discernible with ultrasound and there are two distinct tendons.


Subject(s)
Elbow Joint/diagnostic imaging , Magnetic Resonance Imaging/methods , Tendon Injuries/diagnostic imaging , Tendons/diagnostic imaging , Adult , Elbow Joint/abnormalities , Elbow Joint/anatomy & histology , Female , Humans , Male , Middle Aged , Tendons/abnormalities , Tendons/anatomy & histology , Ultrasonography , Young Adult
10.
Radiol Med ; 117(6): 992-1003, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22580812

ABSTRACT

PURPOSE: Diffusion-weighted imaging (DWI) may improve the diagnostic performance of conventional breast magnetic resonance imaging (MRI). Diffusion tensor imaging (DTI) is an extension of DWI. If DTI-derived measurements are to be clinically useful, particularly for predicting and/or monitoring therapeutic effects, they must be robust and reliable. The purpose of this study was to assess intra- and interobserver reproducibility of DTI-derived fractional anisotropy (FA) and apparent diffusion coefficient (ADC) at 3.0 T. MATERIALS AND METHODS: This prospective study was approved by the Institutional Review Board, and participants provided written informed consent. Sixty normal contralateral breasts of 60 patients (28-85 years, median 57) were analysed with a DWI sequence following a standard MRI protocol. Four authors performed all postprocessing and analyses independently and in different sessions. The same authors, blinded to the initial results, repeated the image postprocessing and analysis 4 weeks after the initial session. RESULTS: Mean ADC and FA for DTI sequences were, respectively, 1.92±0.30 and 0.32±0.09. Intra- and interobserver agreement of the four radiologists for ADC and FA were good (acceptable). Kappa values for ADC were intra-R1=0.82; intra-R2=0.84; intra-R3=0.89; intra-R4=0.88; inter-R1-R2=0.73; inter-R1-R3=0.74; inter-R1-R4=0.81; inter-R2-R3=0.76; inter-R2-R4=0.77; inter-R3-R4=0.83. Kappa values for FA were intra-R1=0.60; intra-R2=0.72; intra-R3=0.84; intra-R4 = 0.66; inter-R1-R2=0.64; inter-R1-R3=0.69; inter-R1-R4=0.72; inter-R2-R3=0.80; inter-R2-R4=0.71; inter-R3-R4=0.73. Within-subject coefficient of variation was 15% for ADC and 30% for FA. Repeatability with α=0.05 was 0.37×10-3 mm(2)/s for ADC and 0.112 for FA. CONCLUSIONS: ADC and FA measurements obtained with DTI are reproducible and may be valid, reliable and sensitive to change. ADC values obtained with DTI are more reproducible than FA.


Subject(s)
Breast/anatomy & histology , Diffusion Magnetic Resonance Imaging/methods , Adult , Aged , Aged, 80 and over , Analysis of Variance , Anisotropy , Female , Humans , Middle Aged , Prospective Studies , Reference Values
11.
Br J Radiol ; 85(1014): e110-6, 2012 Jun.
Article in English | MEDLINE | ID: mdl-21343321

ABSTRACT

OBJECTIVE: The purpose of our study was to determine whether a three-dimensional (3D) isotropic resolution fast spin echo sequence (FSE-cube) has similar image quality and diagnostic performance to a routine MRI protocol for brachial plexus evaluation in volunteers and symptomatic patients at 3.0 T. Institutional review board approval and written informed consent were guaranteed. METHODS: In this prospective study FSE-cube was added to the standard brachial plexus examination protocol in eight patients (mean age, 50.2 years) with brachial plexus pathologies and in six volunteers (mean age, 54 years). Nerve visibility, tissue contrast, edge sharpness, image blurring, motion artefact and acquisition time were calculated for FSE-cube sequences and for the standard protocol on a standardised five-point scale. The visibility of brachial plexus nerve and surrounding tissues at four levels (roots, interscalene area, costoclavicular space and axillary level) was assessed. RESULTS: Image quality and nerve visibility did not significantly differ between FSE-cube and the standard protocol (p>0.05). Acquisition time was statistically and clinically significantly shorter with FSE-cube (p<0.05). Pathological findings were seen equally well with FSE-cube and the standard protocol. CONCLUSION: 3D FSE-cube provided similar image quality in a shorter acquisition time and enabled excellent visualisation of brachial plexus anatomy and pathology in any orientation, regardless of the original scanning plane.


Subject(s)
Brachial Plexus Neuropathies/diagnosis , Brachial Plexus , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Adult , Aged , Humans , Middle Aged , Prospective Studies , Young Adult
12.
Radiol Med ; 116(5): 781-92, 2011 Aug.
Article in English, Polish | MEDLINE | ID: mdl-21424559

ABSTRACT

The purpose of this article is to summarise the early musculoskeletal complications of acromegaly. Some of the early signs of acromegaly may be evaluated by the musculoskeletal radiologist. In the early stage of disease, peripheral nerve enlargement associated with carpal tunnel syndrome or cubital tunnel syndrome and thickening of retinacula, such as A1 pulley in trigger finger, represent the features that may be seen by radiologists and are worthy of an endocrinological evaluation. Due to the insidious nature of the disease, the diagnosis of acromegaly is significantly delayed. Few and nonspecific symptoms characterise the initial phases of the disease, and therefore, most patients will have generally consulted many specialists (most frequently musculoskeletal radiologists) before an adequate endocrinological assessment is performed. For this reason, initial clinical signs are much more important than symptoms for an early diagnosis of acromegaly. The first and most important therapeutic approach to acromegaly is early diagnosis, whereas the therapeutic goals are to eliminate morbidity and reduce mortality to the expected age- and sex-adjusted rates and prevent the development of systemic complications. Musculoskeletal radiologists should be aware that these features may be early manifestations of acromegaly. When both radiological and clinical abnormalities are present, an endocrinological workup is useful to diagnose the disease in an early phase.


Subject(s)
Acromegaly/complications , Diagnostic Imaging , Musculoskeletal Diseases/diagnosis , Musculoskeletal Diseases/etiology , Carpal Tunnel Syndrome/diagnosis , Carpal Tunnel Syndrome/etiology , Cubital Tunnel Syndrome/diagnosis , Cubital Tunnel Syndrome/etiology , Humans , Joint Diseases/diagnosis , Joint Diseases/etiology , Trigger Finger Disorder/diagnosis , Trigger Finger Disorder/etiology
14.
Radiol Med ; 113(2): 214-24, 2008 Mar.
Article in English, Italian | MEDLINE | ID: mdl-18386123

ABSTRACT

PURPOSE: This study was performed to determine the apparent diffusion coefficient (ADC) of the normal kidney using diffusion-weighted magnetic resonance imaging (DW-MRI) sequences and to analyse both the changes due to hydration state and results repeatability. MATERIALS AND METHODS: Ten volunteers underwent DW-MRI imaging of the kidneys with a breath-hold single-shot spin-echo planar imaging (SE-EPI) sequence in the axial and coronal planes with b values of 300, 500, 800 s/mm(2), in different states of hydration. Urine osmolarity (OsmU) and sodium excretion (NaU) were measured at the time of each examination. ADC maps were created for all b values, and ADC values were calculated and compared between different states of hydration. In five subjects, the protocol was conducted twice to test data repeatability. RESULTS: ADC values were lower with higher b values (3.00 vs. 2.47 vs. 1.99 x 10(-3) mm(2)/s with b values of 300, 500, 800 s/mm(2), respectively). ADC values in different hydration states were not statistically different. Measurements were reproducible. OsmU and NaU were statistically different in the different states of hydration (p<0.01). CONCLUSIONS: ADC values significantly decrease with higher b values. Average ADC values in the normal kidney are reproducible. Hydration state does not significantly influence mean ADC values.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Echo-Planar Imaging/methods , Kidney/anatomy & histology , Water-Electrolyte Balance , Adult , Dehydration/diagnosis , Female , Humans , Image Interpretation, Computer-Assisted , Kidney/physiology , Kidney Diseases/diagnosis , Kidney Diseases/physiopathology , Male , Reference Values , Reproducibility of Results , Retrospective Studies , Sodium Chloride/analysis , Sodium Chloride/urine , Urine/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...