Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Fluoresc ; 17(3): 293-300, 2007 May.
Article in English | MEDLINE | ID: mdl-17440799

ABSTRACT

Two simple, sensitive and specific fluorimetric methods have been developed for the determination of some sulphur containing compounds namely, Acetylcysteine (Ac), Carbocisteine (Cc) and Thioctic acid (Th) using terbium Tb+3 and uranium U+3 ions as fluorescent probes. The proposed methods involve the formation of a ternary complex with Tb+3 in presence of Tris-buffer method (I) and a binary complex with aqueous uranyl acetate solution method (II). The fluorescence quenching of Tb+3 at 510, 488 and 540 nm (lambda(ex) 250, 241 and 268 nm) and of uranyl acetate at 512 nm (lambda(ex) 240 nm) due to the complex formation was quantitatively measured for Ac, Cc and Th, respectively. The reaction conditions and the fluorescence spectral properties of the complexes have been investigated. Under the described conditions, the proposed methods were applicable over the concentration range (0.2-2.5 microg ml(-1)), (1-4 microg ml(-1)) and (0.5-3.5 microg ml(-1)) with mean percentage recoveries 99.74+/-0.36, 99.70+/-0.52 and 99.43+/-0.23 for method (I) and (0.5-6 microg ml(-1)), (0.5-5 microg ml(-1)), and (1-6 microg ml(-1)) with mean percentage recoveries 99.38+/-0.20, 99.82+/-0.28 and 99.93+/-0.32 for method (II), for the three cited drugs, respectively. The proposed methods were successfully applied for the determination of the studied compounds in bulk powders and in pharmaceutical formulations, as well as in presence of their related substances. The results obtained were found to be in agree statistically with those obtained by official and reported ones. The two methods were validated according to USP guidelines and also assessed by applying the standard addition technique.


Subject(s)
Spectrometry, Fluorescence/methods , Sulfur Compounds/analysis , Terbium/chemistry , Uranium/chemistry , Acetylcysteine/analysis , Acetylcysteine/chemistry , Carbocysteine/analysis , Carbocysteine/chemistry , Fluorescent Dyes/chemistry , Hydrogen-Ion Concentration , Molecular Structure , Organometallic Compounds/chemistry , Pharmaceutical Preparations/chemistry , Reproducibility of Results , Sulfur Compounds/chemistry , Thioctic Acid/analysis , Thioctic Acid/chemistry
2.
Chem Pharm Bull (Tokyo) ; 55(4): 541-5, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17409544

ABSTRACT

Three reliable, rapid and selective methods have been developed and validated for the determination of lamotrigine in the presence of its impurity, 2,3-dichlorobenzoic acid. The first method is spectrophotometric method using p-chloranilic acid forming a colored product with lambda(max) 519+/-2 nm. All variables affecting the reaction have been investigated and the conditions were optimized. Beer's law was obeyed over a concentration range of 10-200 microg ml(-1) with mean accuracy 100.13+/-0.44%. The molar ratio of the formed ion-association complex is found to be 1 : 1 as deduced by Job's method. The conditional stability constant (K(f)), standard free energy (DeltaG), molar absorptivity(epsilon), and sensitivity index were evaluated. The second method is based on TLC separation of the cited drug (Rf=0.75+/-0.01) from its impurity (Rf=0.23+/-0.01) followed by densitometric measurement of the intact drug spots at 275 nm. The separation was carried on silica gel plates using ethyl acetate : methanol : ammonia 35% (17 : 2 : 1 v/v/v) as a mobile phase. The linearity range was 0.5-10 microg/spot with mean accuracy 99.99+/-1.33%. The third method is accurate and sensitive stability-indicating HPLC method based on separation of lamotrigine from its impurity on a reversed phase C(18) column, using a mobile phase of acetonitrile : methanol : 0.01 M potassium orthophosphate (pH 6.7+/-0.1) (30 : 20 : 50 v/v/v) at ambient temperature 25+/-5 degrees C and UV detection at 275 nm in an overall analysis time of about 6 min., based on peak area. The injection repeatability, intraday and interday repeatability were calculated. The procedure provided a linear response over the concentration range 1-12 microg ml(-1) with mean accuracy of 99.50+/-1.30%. The proposed methods were successfully applied for the determination of lamotrigine in bulk powder, in dosage form and in presence of its impurity. The results obtained were analyzed by ANOVA to assess that no significant difference between each of the three methods and the reported one. The validation was performed according to USP guidelines.


Subject(s)
Anticonvulsants/analysis , Chromatography, High Pressure Liquid/methods , Chromatography, Thin Layer/methods , Triazines/analysis , Lamotrigine , Reproducibility of Results , Sensitivity and Specificity , Spectrophotometry, Ultraviolet
3.
Chem Pharm Bull (Tokyo) ; 54(5): 653-8, 2006 May.
Article in English | MEDLINE | ID: mdl-16651760

ABSTRACT

Two sensitive and selective spectrofluorimetric and spectrophotometric stability-indicating methods have been developed for the determination of some non-steroidal anti-inflammatory oxicam derivatives namely lornoxicam (Lx), tenoxicam (Tx) and meloxicam (Mx) after their complete alkaline hydrolysis. The methods are based on derivatization of alkaline hydrolytic products with 7-chloro-4-nitrobenz-2-oxa-1,3-diazole (NBD-Cl). The products showed an absorption maximum at 460 nm for the three studied drugs and fluorescence emission peak at 535 nm in methanol. The color was stable for at least 48 h. The optimum conditions of the reaction were investigated and it was found that the reaction proceeds quantitatively at pH 8, after heating in a boiling water bath for 30 min. The methods were found to be linear in the ranges of 1-10 microg ml(-1) for Lx and Tx and 0.5-4.0 microg ml(-1) for Mx for spectrophotometric method, while 0.05-1.0 microg ml(-1) for Lx and Tx and 0.025-0.4 microg ml(-1) for Mx for the spectrofluorimetric method. The validity of the methods was assessed according to USP guidelines. Statistical analysis of the results revealed high accuracy and good precision. The suggested procedures could be used for the determination of the above mentioned drugs in pure and dosage forms as well as in the presence of their degradation products.


Subject(s)
Anti-Inflammatory Agents, Non-Steroidal/analysis , Nitrobenzenes/analysis , Oxazoles/analysis , Piroxicam/analogs & derivatives , Thiazines/analysis , Thiazoles/analysis , Buffers , Capsules , Drug Stability , Hydrogen-Ion Concentration , Indicators and Reagents , Meloxicam , Pharmaceutical Solutions , Piroxicam/analysis , Powders , Reproducibility of Results , Spectrometry, Fluorescence , Spectrophotometry, Ultraviolet , Tablets
4.
J AOAC Int ; 87(2): 366-73, 2004.
Article in English | MEDLINE | ID: mdl-15164829

ABSTRACT

Two sensitive and selective methods were developed for the determination of some oxicams, namely, lornoxicam (LOX), tenoxicam (TEX), and meloxicam (MEX), in the presence of their alkaline degradation products. The first method is based on the thin-layer chromatographic separation of the 3 drugs from their alkaline degradation products, followed by densitometric measurement of the intact drug spots for LOX, TEX, and MEX at 380, 370, and 364 nm, respectively. The developing systems used for separation are ethyl acetate-methanol-26% ammonia (17 + 3 + 0.35, v/v/v) for LOX and TEX and chloroform-n-hexane-96.0% acetic acid (18 + 1 + 1, v/v/v) for MEX. The linear ranges were 0.25-6.0 microg/spot for LOX and TEX and 0.5-10 microg/spot for MEX, with mean recoveries of 99.80 +/- 1.32, 100.57 +/- 1.34, and 100.71 +/- 1.57%, respectively. The second method is based on the liquid chromatographic separation of the 3 drugs from their alkaline degradation products on a reversed-phase C18 column, using mobile phases of methanol-acetonitrile-acetate buffer, pH 4.6 (4.5 + 0.5 + 5.0, v/v/v) for LOX and MEX and methanol-acetonitrile-acetate buffer, pH 4.6 (1.9 + 0.1 + 3.0, v/v/v) for TEX at ambient temperature. Quantification is achieved by UV detection at 280 nm, based on peak area. The linear ranges were 0.5-20 microg/mL for LOX and TEX and 1.25-50 microg/mL for MEX, with mean recoveries of 99.81 +/- 1.01, 98.90 +/- 1.61, and 100.86 +/- 1.55%, respectively. The methods were validated according to guidelines of the International Conference on Harmonization. The developed methods were successfully applied to the determination of LOX, TEX, and MEX in bulk powder, laboratory-prepared mixtures containing different percentages of degradation products, and pharmaceutical dosage forms.


Subject(s)
Piroxicam/analogs & derivatives , Piroxicam/analysis , Thiazines/analysis , Thiazoles/analysis , Chromatography, Liquid , Chromatography, Thin Layer , Meloxicam , Sensitivity and Specificity
5.
Chem Pharm Bull (Tokyo) ; 51(12): 1444-7, 2003 Dec.
Article in English | MEDLINE | ID: mdl-14646329

ABSTRACT

Three simple, accurate and sensitive spectrophotometric methods are developed for the determination of some new drugs for the treatment of osteoporosis: risedronate sodium (I), alendronate sodium (II) and etidronate disodium (III). The first method is based on the measurement of difference in absorbance (Delta A) of risedronate sodium in 0.01 mol l(-1) hydrochloric and 0.1 mol l(-1) sodium hydroxide at 262 nm. Beer's law is obeyed over a concentration range of 15-150 microg ml(-1) with mean recovery 99.75+/-1.22 and molar absorptivity (epsilon) 1.891 x 10(3). The second method is based on the reaction of the primary amino group of (II) with ninhydrin reagent in methanolic medium in the presence of 0.05 mol l(-1) sodium bicarbonate. The colored product is measured at 568 nm, and the linearity range is found to be 3.75-45 microg ml(-1) with mean recovery 99.77+/-0.73 and epsilon 9.425 x 10(3). The third method is based on oxidation of the three mentioned drugs with ceric (IV) sulphate in 0.5 mol l(-1) sulphuric acid at room temperature and subsequent measurement of the excess unreacted cerium (IV) sulphate at 320 nm. The method obeyed Beer's law over a concentration range of 2-24 microg ml(-1) for the three drugs with mean recovery 99.79+/-1.16, 99.73+/-1.38 and 99.86+/-1.13 and epsilon 14.427 x 10(3), 13.813 x 10(3) and 14.000 x 10(3) for drugs I, II, III respectively. The proposed methods were successfully applied for the determination of the studied drugs in bulk powder and in pharmaceutical formulations. The results were found to agree statistically with those obtained the reported methods. Furthermore, the methods were validated according to USP regulations and also assessed by applying the standard addition technique.


Subject(s)
Alendronate/analysis , Etidronic Acid/analogs & derivatives , Etidronic Acid/analysis , Osteoporosis/prevention & control , Alendronate/chemistry , Alendronate/therapeutic use , Etidronic Acid/chemistry , Etidronic Acid/therapeutic use , Risedronic Acid , Spectrophotometry/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...