Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Thorac Surg ; 99(1): 307-9, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25555950

ABSTRACT

We report the case of a 69-year-old male patient who was admitted to our department with an acute type A dissection complicated by ischemia of the left lower limb. During surgery for acute type A dissection, the patient underwent concomitant femoro-femoral crossover bypass graft placement to ensure blood supply of the left lower limb during surgery and minimize ischemia-reperfusion injury. The patient underwent supracoronary replacement of the ascending aorta while in deep circulatory arrest with a deepest core temperature of 25°C. Postoperative computed tomography showed antegrade perfusion and patency of the crossover bypass. Postoperative course was eventless without sequelae, especially of the left lower limb. We conclude that concomitant crossover bypass graft reduces the risk of ischemia-reperfusion injury in lower limb ischemia in patients undergoing surgery for acute type A dissection.


Subject(s)
Aortic Aneurysm/complications , Aortic Aneurysm/surgery , Aortic Dissection/complications , Aortic Dissection/surgery , Femoral Artery/surgery , Ischemia/complications , Ischemia/surgery , Leg/blood supply , Aged , Humans , Male , Time Factors , Vascular Surgical Procedures/methods
2.
Ann Thorac Surg ; 98(4): 1301-7, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25149050

ABSTRACT

BACKGROUND: The Sorin Freedom SOLO (FS) bovine pericardial stentless valve prosthesis is designed for supraannular, subcoronary implantation. We report our experience and results with 277 consecutively implanted FS bioprostheses. METHODS: 277 patients (mean age, 74.2 ± 7.3 years; 139 (50.2%) female) underwent aortic valve replacement (AVR) with the FS stentless bioprosthesis. The hemodynamic performance was investigated with transthoracic echocardiography at discharge, 6 months later, and yearly thereafter. Follow-up was 100% complete, with an average observation time of 2.6 ± 1.7 years and a total of 697.3 patient-years. RESULTS: The overall 30-day mortality was 4.3%. The mortalities for isolated AVR and combined procedures were 1.9% and 7.3%, respectively. No causes of death were valve-related. Preoperative peak (74.2 ± 23.0 mm Hg) and mean (48.6 ± 16.3 mm Hg) gradients decreased to 15.6 ± 5.4 mm Hg and 8.8 ± 3.0 mm Hg postoperatively and remained unchanged for as long as 5 years. The postoperative mean effective orifice area (EOA) for valve sizes 19, 21, 23, 25, and 27 were 1.49 ± 0.32 cm(2), 1.67 ± 0.40 cm(2), 1.92 ± 0.38 cm(2), 2.01 ± 0.42 cm(2), and 2.13 ± 0.36 cm(2), respectively. Severe prosthesis-patient mismach (PPM) was completely absent, and moderate PPM occurred in 17 patients (6.1%). In isolated AVR, 0.8% of patients with preoperative sinus rhythm required a permanent pacemaker before hospital discharge. There was 100% freedom from structural valve deterioration, 99.6 % freedom from endocarditis and reoperation, and 97.3% freedom from thromboembolism at 5 years. CONCLUSIONS: The FS stentless aortic valve is safe to implant, and it shows excellent hemodynamic performance and early and midterm results. Owing to the favorable EOA, the valve appears particularly attractive for patients at risk for PPM.


Subject(s)
Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Aged , Aged, 80 and over , Animals , Cattle , Female , Heart Valve Prosthesis Implantation/mortality , Hemodynamics , Humans , Male , Middle Aged
3.
Aorta (Stamford) ; 2(4): 152-5, 2014 Aug.
Article in English | MEDLINE | ID: mdl-26798734

ABSTRACT

We report the case of an 82-year-old female who presented in a hemodynamically unstable condition to the emergency department of our institution. Transthoracic echo showed a hemodynamically relevant pericardial effusion and the suspicion of an intimal flap in the ascending aorta. The subsequent computed tomography scan revealed a Type A dissection that was limited to the ascending aorta. To prevent hemodynamic deterioration the patient was prepped and draped awake and underwent femoral cannulation for extracorporeal circulation under local anesthesia. After commencing extracorporeal circulation the patient was anesthetized and intubated. During this whole time period no relevant drop in mean arterial pressure was observed. The patient underwent routine replacement of the ascending aorta and was extubated the day after surgery without any neurologic sequelae. Awake cannulation and inception of extracorporeal circulation can prevent the hemodynamic deterioration and cardiac arrest often seen during induction of anesthesia in patients with cardiac tamponade.

SELECTION OF CITATIONS
SEARCH DETAIL
...