Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 22(24)2022 Dec 13.
Article in English | MEDLINE | ID: mdl-36560127

ABSTRACT

In this study, we propose a single camera-based dual-channel near-infrared (NIR) fluorescence imaging system that produces color and dual-channel NIR fluorescence images in real time. To simultaneously acquire color and dual-channel NIR fluorescence images of two fluorescent agents, three cameras and additional optical parts are generally used. As a result, the volume of the image acquisition unit increases, interfering with movements during surgical procedures and increasing production costs. In the system herein proposed, instead of using three cameras, we set a single camera equipped with two image sensors that can simultaneously acquire color and single-channel NIR fluorescence images, thus reducing the volume of the image acquisition unit. The single-channel NIR fluorescence images were time-divided into two channels by synchronizing the camera and two excitation lasers, and the noise caused by the crosstalk effect between the two fluorescent agents was removed through image processing. To evaluate the performance of the system, experiments were conducted for the two fluorescent agents to measure the sensitivity, crosstalk effect, and signal-to-background ratio. The compactness of the resulting image acquisition unit alleviates the inconvenient movement obstruction of previous devices during clinical and animal surgery and reduces the complexity and costs of the manufacturing process, which may facilitate the dissemination of this type of system.


Subject(s)
Fluorescent Dyes , Indocyanine Green , Animals , Optical Imaging/methods , Image Processing, Computer-Assisted , Fluorescence
2.
Sensors (Basel) ; 22(15)2022 Jul 26.
Article in English | MEDLINE | ID: mdl-35898101

ABSTRACT

We developed a single-camera-based near-infrared (NIR) fluorescence imaging device using indocyanine green (ICG) NIR fluorescence contrast agents for image-induced surgery. In general, a fluorescent imaging system that simultaneously provides color and NIR images uses two cameras, which is disadvantageous because it increases the imaging head of the system. Recently, a single-camera-based NIR optical imaging device with quantum efficiency partially extended to the NIR region was developed to overcome this drawback. The system used RGB_NIR filters for camera sensors to provide color and NIR images simultaneously; however, the sensitivity and resolution of the infrared images are reduced by 1/4, and the exposure time and gain cannot be set individually when acquiring color and NIR images. Thus, to overcome these shortcomings, this study developed a compact fluorescent imaging system that uses a single camera with two complementary metal-oxide semiconductor (CMOS) image sensors. Sensitivity and signal-to-background ratio were measured according to the concentrations of ICG solution, exposure time, and camera gain to evaluate the performance of the imaging system. Consequently, the clinical applicability of the system was confirmed through the toxicity analysis of the light source and in vivo testing.


Subject(s)
Indocyanine Green , Optical Imaging , Fluorescence , Fluorescent Dyes , Optical Imaging/methods , Oxides , Semiconductors
3.
Sensors (Basel) ; 20(11)2020 May 29.
Article in English | MEDLINE | ID: mdl-32485985

ABSTRACT

Whole slide imaging (WSI) refers to the process of creating a high-resolution digital image of a whole slide. Since digital images are typically produced by stitching image sequences acquired from different fields of view, the visual quality of the images can be degraded owing to shading distortion, which produces black plaid patterns on the images. A shading correction method for brightfield WSI is presented, which is simple but robust not only against typical image artifacts caused by specks of dust and bubbles, but also against fixed-pattern noise, or spatial variations in pixel values under uniform illumination. The proposed method comprises primarily of two steps. The first step constructs candidates of a shading distortion model from a stack of input image sequences. The second step selects the optimal model from the candidates. The proposed method was compared experimentally with two previous state-of-the-art methods, regularized energy minimization (CIDRE) and background and shading correction (BaSiC) and showed better correction scores, as smooth operations and constraints were not imposed when estimating the shading distortion. The correction scores, averaged over 40 image collections, were as follows: proposed method, 0.39 ± 0.099; CIDRE method, 0.67 ± 0.047; BaSiC method, 0.55 ± 0.038. Based on the quantitative evaluations, we can confirm that the proposed method can correct not only shading distortion, but also fixed-pattern noise, compared with the two previous state-of-the-art methods.


Subject(s)
Algorithms , Image Processing, Computer-Assisted , Lighting , Microscopy/methods , Color
4.
Cerebrovasc Dis ; 32(6): 567-76, 2011.
Article in English | MEDLINE | ID: mdl-22104691

ABSTRACT

BACKGROUND: Conventional stroke registries contain alphanumeric text-based data on the clinical status of stroke patients, but this format captures imaging data in a very limited form. There is a need for a new type of stroke registry to capture both text- and image-based data. METHODS AND RESULTS: We designed a next-generation stroke registry containing quantitative magnetic resonance imaging (MRI) data, 'DUIH_SRegI', developed a supporting software package, 'Image_QNA', and performed experiments to assess the feasibility and utility of the system. Image_QNA enabled the mapping of stroke-related lesions on MR onto a standard brain template and the storage of this extracted imaging data in a visual database. Interuser and intrauser variability of the lesion mapping procedure was low. We compared the results from the semi automatic lesion registration using Image_QNA with automatic lesion registration using SPM5 (Statistical Parametric Mapping version 5), a well-regarded standard neuroscience software package, in terms of lesion location, size and shape, and found Image_QNA to be superior. We assessed the clinical usefulness of an image-based registry by studying 47 consecutive patients with first-ever lacunar infarcts in the corona radiata. We used the enriched dataset comprised of both image-based and alphanumeric databases to show that diffusion MR lesions overlapped in a more posterolateral brain location for patients with high NIH Stroke Scale scores (≥4) than for patients with low scores (≤3). In April 2009, we launched the first prospective image-based acute (≤1 week) stroke registry at our institution. The registered data include high signal intensity ischemic lesions on diffusion, T(2)-weighted, or fluid attenuation inversion recovery MRIs, and low signal intensity hemorrhagic lesions on gradient-echo MRIs. An interim analysis at 6 months showed that the time requirement for the lesion registration (183 consecutive patients, 3,226 MR slices with visible stroke-related lesions) was acceptable at about 1 h of labor per patient by a trained assistant with physician oversight. CONCLUSIONS: We have developed a novel image-based stroke registry, with database functions that allow the formulation and testing of intuitive, image-based hypotheses in a manner not easily achievable with conventional alphanumeric stroke registries.


Subject(s)
Magnetic Resonance Imaging/statistics & numerical data , Registries , Stroke/pathology , Aged , Cerebral Infarction/pathology , Databases, Factual , Echo-Planar Imaging , Feasibility Studies , Female , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Reproducibility of Results , Software
SELECTION OF CITATIONS
SEARCH DETAIL
...