1.
J Magn Reson Open ; 16-172023 Dec.
Article in English | MEDLINE | ID: mdl-38046796

ABSTRACT

In light of the growing interest in-vivo deuterium metabolic imaging, hyperpolarized 13C, 15N, 3He, and 129Xe imaging, as well as 31P spectroscopy and imaging in large animals on clinical MR scanners, we demonstrate the use of a (radio)frequency converter system to allow X-nuclear MR spectroscopy (MRS) and MR imaging (MRI) on standard clinical MRI scanners without multinuclear capability. This is not only an economical alternative to the multinuclear system (MNS) provided by the scanner vendors, but also overcomes the frequency bandwidth problem of some vendor-provided MNSs that prohibit users from applications with X-nuclei of low magnetogyric ratio, such as deuterium (6.536 MHz/Tesla) and 15N (-4.316 MHz/Tesla). Here we illustrate the design of the frequency converter system and demonstrate its feasibility for 31P (17.235 MHz/Tesla), 13C (10.708 MHz/Tesla), and 15N MRS and MRI on a clinical MRI scanner without vendor-provided multinuclear hardware.

2.
J Magn Reson Open ; 16-172023 Dec.
Article in English | MEDLINE | ID: mdl-38046795

ABSTRACT

We report several inductively coupled RF coil designs that are very easy to construct, produce high signal-to-noise ratio (SNR) and high spatial resolution while accommodating life support, anesthesia and monitoring in small animals. Inductively coupled surface coils were designed for hyperpolarized 13 C MR spectroscopic imaging (MRSI) of mouse brain, with emphases on the simplicity of the circuit design, ease of use, whole-brain coverage, and high SNR. The simplest form was a resonant loop designed to crown the mouse head for a snug fit to achieve full coverage of the brain with high sensitivity when inductively coupled to a broadband pick-up coil. Here, we demonstrated the coil's performance in hyperpolarized 13 C MRSI of a normal mouse and a glioblastoma mouse model at 4.7 T. High SNR exceeding 70:1 was obtained in the brain with good spatial resolution (1.53 mm × 1.53 mm). Similar inductively coupled loop for other X-nuclei can be made very easily in a few minutes and achieve high performance, as demonstrated in 31 P spectroscopy. Similar design concept was expanded to splitable, inductively coupled volume coils for high-resolution proton MRI of marmoset at 3T and 9.4T, to easily accommodate head restraint, vital-sign monitoring, and anesthesia delivery.

3.
IEEE Trans Med Imaging ; 35(8): 1824-36, 2016 08.
Article in English | MEDLINE | ID: mdl-26915118

ABSTRACT

Simultaneous Multi-Slice (SMS) magnetic resonance imaging (MRI) is a rapidly evolving technique for increasing imaging speed. Controlled aliasing techniques utilize periodic undersampling patterns to help mitigate the loss in signal-to-noise ratio (SNR) in SMS MRI. To evaluate the performance of different undersampling patterns, a quantitative description of the image SNR loss is needed. Additionally, eddy current effects in echo planar imaging (EPI) lead to slice-specific Nyquist ghosting artifacts. These artifacts cannot be accurately corrected for each individual slice before or after slice-unaliasing. In this work, we propose a hybrid-space sensitivity encoding (SENSE) reconstruction framework for SMS MRI by adopting a three-dimensional representation of the SMS acquisition. Analytical SNR loss maps are derived for SMS acquisitions with arbitrary phase encoding undersampling patterns. Moreover, we propose a matrix-decoding correction method that corrects the slice-specific Nyquist ghosting artifacts in SMS EPI acquisitions. Brain images demonstrate that the proposed hybrid-space SENSE reconstruction generates images with comparable quality to commonly used split-slice-generalized autocalibrating partially parallel acquisition reconstruction. The analytical SNR loss maps agree with those calculated by a Monte Carlo based method, but require less computation time for high quality maps. The analytical maps enable a fair comparison between the performances of coherent and incoherent SMS undersampling patterns. Phantom and brain SMS EPI images show that the matrix-decoding method performs better than the single-slice and slice-averaged Nyquist ghosting correction methods under the hybrid-space SENSE reconstruction framework.


Subject(s)
Magnetic Resonance Imaging , Artifacts , Brain , Echo-Planar Imaging , Humans , Phantoms, Imaging , Signal-To-Noise Ratio
4.
Magn Reson Imaging ; 29(4): 470-82, 2011 May.
Article in English | MEDLINE | ID: mdl-21440400

ABSTRACT

There is increasing interest in imaging short T2 species which show little or no signal with conventional magnetic resonance (MR) pulse sequences. In this paper, we describe the use of three-dimensional ultrashort echo time (3D UTE) sequences with TEs down to 8 µs for imaging of these species. Image contrast was generated with acquisitions using dual echo 3D UTE with echo subtraction, dual echo 3D UTE with rescaled subtraction, long T2 saturation 3D UTE, long T2 saturation dual echo 3D UTE with echo subtraction, single adiabatic inversion recovery 3D UTE, single adiabatic inversion recovery dual echo 3D UTE with echo subtraction and dual adiabatic inversion recovery 3D UTE. The feasibility of using these approaches was demonstrated in in vitro and in vivo imaging of calcified cartilage, aponeuroses, menisci, tendons, ligaments and cortical bone with a 3-T clinical MR scanner. Signal-to-noise ratios and contrast-to-noise ratios were used to compare the techniques.


Subject(s)
Echo-Planar Imaging/methods , Image Processing, Computer-Assisted/methods , Animals , Bone and Bones/metabolism , Bone and Bones/pathology , Diagnostic Imaging/methods , Humans , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Male , Middle Aged , Muscles/pathology , Patella/pathology , Swine , Tendons/pathology , Tibia/pathology , Time Factors
5.
Magn Reson Med ; 63(2): 447-55, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20099332

ABSTRACT

Imaging of short-T(2) species requires not only a short echo time but also efficient suppression of long-T(2) species in order to maximize the short-T(2) contrast and dynamic range. This paper introduces a method of long-T(2) suppression using two long adiabatic inversion pulses. The first adiabatic inversion pulse inverts the magnetization of long-T(2) water and the second one inverts that of fat. Short-T(2) species experience a significant transverse relaxation during the long adiabatic inversion process and are minimally affected by the inversion pulses. Data acquisition with a short echo time of 8 mus starts following a time delay of inversion time (TI1) for the inverted water magnetization to reach a null point and a time delay of TI2 for the inverted fat magnetization to reach a null point. The suppression of long-T(2) species depends on proper combination of TI1, TI2, and pulse repetition time. It is insensitive to radiofrequency inhomogeneities because of the adiabatic inversion pulses. The feasibility of this dual inversion recovery ultrashort echo time technique was demonstrated on phantoms, cadaveric specimens, and healthy volunteers, using a clinical 3-T scanner. High image contrast was achieved for the deep radial and calcified layers of articular cartilage, cortical bone, and the Achilles tendon.


Subject(s)
Algorithms , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Signal Processing, Computer-Assisted , Humans , Magnetic Resonance Imaging/instrumentation , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity
6.
Magn Reson Med ; 62(2): 527-31, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19449436

ABSTRACT

Short T(2) species such as the Achilles tendon and cortical bone cannot be imaged with conventional MR sequences. They have a much broader absorption lineshape than long T(2) species, therefore they are more sensitive to an appropriately placed off-resonance irradiation. In this work, a technique termed ultrashort TE (UTE) with off-resonance saturation contrast (UTE-OSC) is proposed to image short T(2) species. A high power saturation pulse was placed +1 to +2 kHz off the water peak to preferentially saturate signals from short T(2) species, leaving long T(2) water and fat signals largely unaffected. The subtraction of UTE images with and without an off-resonance saturation pulse effectively suppresses long T(2) water and fat signals, creating high contrast for short T(2) species. The UTE-OSC technique was validated on a phantom, and applied to bone samples and healthy volunteers on a clinical 3T scanner. High-contrast images of the Achilles tendon and cortical bone were generated with a high contrast-to-noise ratio (CNR) of the order of 12 to 20 between short T(2) and long T(2) species within a total scan time of 4 to 10 min.


Subject(s)
Achilles Tendon/anatomy & histology , Algorithms , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Signal Processing, Computer-Assisted , Tibia/anatomy & histology , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
7.
Exp Neurol ; 217(2): 320-7, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19306870

ABSTRACT

It is difficult to assess cerebral function in comatose patients. Because earlier functional neuroimaging studies demonstrate associations between cerebral metabolism and levels of consciousness, fMRI in comatose survivors of cardiac arrest could provide further insight into cerebral function during coma. Using fMRI, cerebral activation to somatosensory stimulation to the palm of the hand was measured in 19 comatose survivors of cardiac arrest and in 10 healthy control subjects and was compared to somatosensory-evoked potential (SSEP) testing of the median nerve. Changes in the blood oxygenation-level dependent signal (BOLD) in the primary somatosensory cortex (S1) contralateral to the stimulated hand were quantified. Clinical outcome was assessed using the Glasgow Outcome Scale (GOS) and the modified Rankin Scale at 3 months post-cardiac arrest. Five out of 19 patients were alive at 3 months. Patients who survived cardiac arrest showed greater BOLD in S1 contralateral to somatosensory stimulation of the hand compared to patients who eventually did not. Greater BOLD was also seen in S1 of patients who retained their SSEP N20 waveforms. There were also positive correlations between BOLD in S1 with both levels of consciousness and measures of outcome at 3 months. In summary, this study demonstrates that BOLD in the S1 contralateral to somatosensory stimulation of the hand varies with clinical measures of the level of consciousness during coma.


Subject(s)
Coma/physiopathology , Death, Sudden, Cardiac , Evoked Potentials, Somatosensory/physiology , Hypoxia-Ischemia, Brain/complications , Somatosensory Cortex/physiopathology , Adolescent , Adult , Aged , Aged, 80 and over , Brain Mapping , Cerebrovascular Circulation/physiology , Coma/etiology , Female , Functional Laterality/physiology , Glasgow Outcome Scale , Humans , Magnetic Resonance Imaging , Male , Median Nerve , Middle Aged , Physical Stimulation , Survival Rate
8.
J Magn Reson Imaging ; 29(2): 412-21, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19161197

ABSTRACT

PURPOSE: To investigate ultrashort TE spectroscopic imaging (UTESI) of short T2 tissues in the musculoskeletal (MSK) system. MATERIALS AND METHODS: Ultrashort TE pulse sequence is able to detect rapidly decaying signals from tissues with a short T2 relaxation time. Here a time efficient spectroscopic imaging technique based on a multiecho interleaved variable TE UTE acquisition is proposed for high-resolution spectroscopic imaging of the short T2 tissues in the MSK system. The projections were interleaved into multiple groups with the data for each group being collected with progressively increasing TEs. The small number of projections in each group sparsely but uniformly sampled k-space. Spectroscopic images were generated through Fourier transformation of the time domain images at variable TEs. T2* was quantified through exponential fitting of the time domain images or line shape fitting of the magnitude spectrum. The feasibility of this technique was demonstrated in volunteer and cadaveric specimen studies on a clinical 3T scanner. RESULTS: UTESI was applied to six cadaveric specimens and four human volunteers. High spatial resolution and contrast images were generated for the deep radial and calcified layers of articular cartilage, menisci, ligaments, tendons, and entheses, respectively. Line shape fitting of the UTESI magnitude spectroscopic images show a short T2* of 1.34 +/- 0.56 msec, 4.19 +/- 0.68 msec, 3.26 +/- 0.34 msec, 1.96 +/- 0.47 msec, and 4.21 +/- 0.38 msec, respectively. CONCLUSION: UTESI is a time-efficient method to image and characterize the short T2 tissues in the MSK system with high spatial resolution and high contrast.


Subject(s)
Cartilage, Articular/anatomy & histology , Ligaments/anatomy & histology , Magnetic Resonance Spectroscopy/methods , Tendons/anatomy & histology , Cadaver , Humans , Image Processing, Computer-Assisted , Menisci, Tibial/anatomy & histology
9.
Magn Reson Imaging ; 26(3): 304-12, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18096346

ABSTRACT

Tissues with very short transverse relaxation time (T2) cannot be detected using conventional magnetic resonance (MR) sequences due to the rapid decay of excited MR signals. In this work, a multiecho sequence employing half-pulse excitation and spiral sampling was developed for ultrashort echo time (UTE) imaging of tissues with short T2. Spiral readout gradients were measured and precompensated to reduce gradient distortions due to eddy currents and gradient anisotropy. The effects of spatial blurring due to fast signal decay were investigated experimentally through spiral UTE (SUTE) imaging of rubber bands with different spiral sampling duration. The unwanted long T2 signals were suppressed through the use of an inversion pulse and nulling, and/or subtraction of a later echo image from the initial one. This technique has been applied to imaging of the short T2 components in brain white matter, knee cartilage, bone and carotid vessel wall of normal volunteers at 1.5 T. Preliminary results show high spatial resolution and excellent image contrast for a variety of short T2 tissues in the human body under a relatively short scan time. A quantitative comparison was also made between radial UTE and SUTE in terms of signal-to-noise ratio efficiency.


Subject(s)
Image Enhancement/methods , Magnetic Resonance Imaging/methods , Adult , Anisotropy , Artifacts , Blood Vessels/anatomy & histology , Bone and Bones/anatomy & histology , Brain Mapping/methods , Cartilage, Articular/anatomy & histology , Humans , Phantoms, Imaging
10.
Magn Reson Med ; 47(5): 921-8, 2002 May.
Article in English | MEDLINE | ID: mdl-11979571

ABSTRACT

The reproducibility of quantitative cerebral blood flow (CBF) measurements using MRI with arterial spin labeling and acetazolamide challenge was assessed in 12 normal subjects, each undergoing the identical experimental procedure on two separate days. CBF was measured on a 1.5T scanner using a flow-sensitive alternating inversion recovery (FAIR) pulse sequence, performed both at baseline and 12 min after intravenous administration of acetazolamide. T(1) was measured in conjunction with the FAIR scan in order to calculate quantitative CBF. The CBF maps were segmented to separate gray matter (GM) from white matter (WM) for region-of-interest (ROI) analyses. Post- acetazolamide CBF values (ml/100 g/min, mean +/- SD) of 87.5 +/- 12.5 (GM) and 46.1 +/- 10.8 (WM) represented percent increases of 37.7% +/- 24.4% (GM) and 40.1% +/- 24.4% (WM). Day-to-day differences in baseline CBF were -1.7 +/- 6.9 (GM) and -1.4 +/- 4.7 (WM) or, relative to the mean CBF over both days for each subject, -2.5% +/- 11.7% (GM) and -3.8% +/- 13.6% (WM) Day- to-day differences in absolute post-ACZ CBF increase were -2.5 +/- 6.8 (GM) and 2.7 +/- 9.4 (WM) or, relative to the mean CBF increase over both days for each subject, -4.7% +/- 13.3% (GM) and 9.1% +/- 26.2% (WM). Thus, FAIR- based CBF measurements show satisfactory reproducibility from day to day, but with sufficient variation to warrant caution in interpreting longitudinal data. The hemispheric asymmetry of baseline CBF and post-acetazolamide CBF increases varied within a narrower range and should be sensitive to small changes related to disease or treatment.


Subject(s)
Cerebrovascular Circulation/physiology , Magnetic Resonance Imaging/methods , Acetazolamide , Adult , Aged , Female , Humans , Male , Middle Aged , Reproducibility of Results , Spin Labels