Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 36
Filter
1.
Acute Med Surg ; 11(1): e929, 2024.
Article in English | MEDLINE | ID: mdl-38385144

ABSTRACT

Post-intensive care syndrome comprises physical, cognitive, and mental impairments in patients treated in an intensive care unit (ICU). It occurs either during the ICU stay or following ICU discharge and is related to the patients' long-term prognosis. The same concept also applies to pediatric patients, and it can greatly affect the mental status of family members. In the 10 years since post-intensive care syndrome was first proposed, research has greatly expanded. Here, we summarize the recent evidence on post-intensive care syndrome regarding its pathophysiology, epidemiology, assessment, risk factors, prevention, and treatments. We highlight new topics, future directions, and strategies to overcome post-intensive care syndrome among people treated in an ICU. Clinical and basic research are still needed to elucidate the mechanistic insights and to discover therapeutic targets and new interventions for post-intensive care syndrome.

2.
Stud Health Technol Inform ; 310: 1343-1344, 2024 Jan 25.
Article in English | MEDLINE | ID: mdl-38270035

ABSTRACT

To effectively use data from intensive care unit patient information systems at multiple hospitals, it is necessary to standardize the data into a well-ordered form. However, terms often vary between devices. We designed a mechanical ventilation concept model and applied data to that model using existing tools and expert opinions. The JSICM glossary was revised based on this study.


Subject(s)
Critical Care , Respiration, Artificial , Humans , Japan , Hospitals
3.
J Clin Monit Comput ; 38(1): 77-88, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37792139

ABSTRACT

PURPOSE: Non-contact continuous respiratory rate monitoring is preferred for early detection of patient deterioration. However, this technique is under development; a gold standard respiratory monitor has not been established. Therefore, this prospective observational method comparison study aimed to compare the measurement accuracy of a non-contact continuous respiratory rate monitor, a microwave Doppler sensor positioned beneath the mattress, with that of other monitors. METHODS: The respiratory rate of intensive care unit patients was simultaneously measured using a microwave Doppler sensor, capnography, thoracic impedance pneumography, and a piezoelectric sensor beneath the mattress. Bias and 95% limits of agreement between the respiratory rate measured using capnography (standard reference) and that measured using the other three methods were calculated using Bland-Altman analysis for repeated measures. Clarke error grid (CEG) analysis evaluated the sensor's ability to assist in correct clinical decision-making. RESULTS: Eighteen participants were included, and 2,307 data points were analyzed. The bias values (95% limits of agreement) of the microwave Doppler sensor, thoracic impedance pneumography, and piezoelectric sensor were 0.2 (- 4.8 to 5.2), 1.5 (- 4.4 to 7.4), and 0.4 (- 4.0 to 4.8) breaths per minute, respectively. Clinical decisions evaluated using CEG analyses were correct 98.1% of the time for the microwave Doppler sensor, which was similar to the performance of the other devices. CONCLUSION: The microwave Doppler sensor had a small bias but relatively low precision, similar to other devices. In CEG analyses, the risk of each monitor leading to inadequate clinical decision-making was low. TRIAL REGISTRATION NUMBER: UMIN000038900, February 1, 2020.


Subject(s)
Microwaves , Respiratory Rate , Humans , Reproducibility of Results , Monitoring, Physiologic/methods , Capnography/methods
4.
Crit Care ; 27(1): 430, 2023 11 07.
Article in English | MEDLINE | ID: mdl-37936249

ABSTRACT

BACKGROUND: The assessment of post-intensive care syndrome (PICS) is challenging due to the numerous types of instruments. We herein attempted to identify and propose recommendations for instruments to assess PICS in intensive care unit (ICU) survivors. METHODS: We conducted a scoping review to identify PICS follow-up studies at and after hospital discharge between 2014 and 2022. Assessment instruments used more than two times were included in the modified Delphi consensus process. A modified Delphi meeting was conducted three times by the PICS committee of the Japanese Society of Intensive Care Medicine, and each score was rated as not important (score: 1-3), important, but not critical (4-6), and critical (7-9). We included instruments with ≥ 70% of respondents rating critical and ≤ 15% of respondents rating not important. RESULTS: In total, 6972 records were identified in this scoping review, and 754 studies were included in the analysis. After data extraction, 107 PICS assessment instruments were identified. The modified Delphi meeting reached 20 PICS assessment instrument recommendations: (1) in the physical domain: the 6-min walk test, MRC score, and grip strength, (2) in cognition: MoCA, MMSE, and SMQ, (3) in mental health: HADS, IES-R, and PHQ-9, (4) in the activities of daily living: the Barthel Index, IADL, and FIM, (5) in quality of life: SF-36, SF-12, EQ-5D-5L, 3L, and VAS (6), in sleep and pain: PSQI and Brief Pain Inventory, respectively, and (7) in the PICS-family domain: SF-36, HADS, and IES-R. CONCLUSION: Based on a scoping review and the modified Delphi method, 20 PICS assessment instruments are recommended to assess physical, cognitive, mental health, activities of daily living, quality of life, sleep, and pain in ICU survivors and their families.


Subject(s)
Intensive Care Units , Quality of Life , Humans , Activities of Daily Living , Delphi Technique , Critical Care/methods , Critical Illness/therapy , Critical Illness/psychology , Pain
5.
J Clin Med ; 12(16)2023 Aug 21.
Article in English | MEDLINE | ID: mdl-37629468

ABSTRACT

BACKGROUND: Persistent inflammation, immunosuppression, and catabolism syndrome (PIICS) is known as a prolonged immunodeficiency that occurs after severe infection. Few studies have demonstrated a direct relationship between PIICS and physical dysfunction in post-intensive care syndrome (PICS). We herein investigated how each component of PICS was affected by the diagnosis of PIICS during hospitalization and examined the relationship between PIICS and PICS using PICS assessments performed at the Hitachi General Hospital PICS Clinic. METHODS: The 273 patients who visited the PICS clinic at one month after discharge from the ICU at Hitachi General Hospital were included in the study. We used the diagnostic criteria for PIICS described in previous studies. At least two of the following blood test values on day 14 of hospitalization had to be met for a diagnosis of PIICS: C-reactive protein (CRP) > 2.0 mg/dL, albumin (Alb) < 3.0 g/dL, and lymphocytes (Lym) < 800/µL. Blood test values closest to day 14 out of 11-17 days of hospitalization were used. The primary outcome was a Barthel Index (BI) < 90, while secondary outcomes were the results of various PICS assessments, including mental and cognitive impairments, performed at the PICS clinic. We supplemented missing data with multiple imputations by chained equations. We performed a nominal logistic regression analysis with age, sex, BMI, SOFA, and the presence of PIICS as variables for BI < 90. RESULTS: Forty-three out of two hundred seventy-three PICS outpatients met the diagnostic criteria for PIICS during hospitalization. In comparisons with non-PIICS patients, significantly higher severity scores for APACHE II and SOFA and a longer hospital stay were observed in PIICS patients, suggesting a higher clinical severity. The primary outcome, BI, was lower in the PIICS group (97.5 (58.5, 100) vs. 100 (95, 100), p = 0.008), as were the secondary outcomes (FSS-ICU: 35 (31, 35) vs. 35 (35, 35), MRC score: 55 (50.25, 58) vs. 58 (53, 60), grip strength: 16.45 (9.2, 25.47) vs. 20.4 (15.3, 27.7)). No significant differences were noted in mental or cognitive function assessments, such as HADS, IES-R, and SMQ. A multivariable analysis supplemented with missing data revealed that PIICS (odds ratio: 1.23 (1.08-1.40 p = 0.001) and age (odds ratio: 1.007 (1.004-1.01), p < 0.001) correlated with BI < 90, independent of clinical severity such as sequential organ failure assessment (SOFA). Similar results were obtained in the sensitivity analysis excluding missing data. CONCLUSIONS: The present study revealed a strong relationship between PIICS and post-discharge PICS physical dysfunction in patients requiring intensive care.

6.
J Intensive Care ; 11(1): 25, 2023 May 30.
Article in English | MEDLINE | ID: mdl-37254206

ABSTRACT

BACKGROUND: Post-pyloric enteral feeding reduces respiratory complications and shortens the duration of mechanical ventilation. Blind placement of post-pyloric enteral feeding tubes (EFT) in patients with critical illnesses is often the first-line method because endoscopy or fluoroscopy cannot be easily performed at bedside; however, difficult placements regularly occur. We reported an association between the stomach position caudal to spinal level L1-L2, evaluated by abdominal radiographs after placement, and difficult placement; however, this method could not indicate difficulty before EFT placement. The aim of our study was to evaluate the association between stomach position, estimated using computed tomography (CT) images taken before the blind placement of the post-pyloric EFT, and the difficulty of EFT placement. METHODS: Data from patients aged ≥ 20 years who underwent post-pyloric EFT in our intensive care unit were obtained retrospectively. Logistic regression analysis was used to evaluate the association between successful initial EFT placement and explanatory variables, including stomach position estimated by CT. Two cut-off values were used: caudal to L1-L2 based on a previous study and the best cut-off value calculated by the receiver operating characteristic curve. Variable selection was performed backward stepwise using Akaike's Information Criterion. RESULTS: Of the total of 453 patients who were enrolled, the success rate of the initial EFT placement was 43.5%. The adjusted odds ratio for successful initial EFT placement of the stomach position caudal to L1-L2 was 0.61 (95% confidence interval: 0.41-1.07). Logistic regression analysis, including the stomach position caudal to L2-L3, calculated as the best cut-off value, indicated that stomach position was an independent factor for failure of initial EFT placement (adjusted odds ratio, 0.55; 95% confidence interval: 0.33-0.91). CONCLUSIONS: Stomach position evaluated using CT images was associated with successful initial post-pyloric EFT placement. The best cut-off value of the greater curvature of the stomach to predict the success or failure of the first attempt was spinal level L2-L3. Trial registration University Hospital Medical Information Network Clinical Trials Registry (UMIN000046986; February 28, 2022). https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000052151.

7.
J Clin Med ; 13(1)2023 Dec 19.
Article in English | MEDLINE | ID: mdl-38202016

ABSTRACT

Acute kidney injury (AKI) after cardiac surgery is a common complication that can lead to death. We previously reported that the creatinine reduction ratio (CRR) serves as a useful prognostic factor for AKI. The primary objective of this study was to determine the predictors of AKI after surgery. The secondary objective was to determine the reliability of the CRR for short- and long-term outcomes. We retrospectively collected information about cardiac surgery patients who underwent cardiopulmonary bypass. Patients were divided into AKI and non-AKI groups based on the AKIN and RIFLE criteria. We analyzed the two groups regarding the preoperative patient data and operative information. The CRR was calculated as follows: (preoperative creatinine-postoperative creatinine)/preoperative creatinine. The prognostic factors of AKI-CS were surgery time, CPB time, aorta clamp time, platelet transfusion, and CRR < 20%. In the multivariate logistical analysis, CRR was an independent predictor of AKI (adjusted odds ratio: 0.90 [0.87-0.93], p < 0.001). However, there were no significant differences in CRR in terms of the rate of new onset chronic kidney disease (CKD). After cardiac surgery with cardiopulmonary bypass, CRR has good diagnostic power for predicting perioperative AKI. However, we cannot use it as a prognostic factor over a long-term period.

8.
J Clin Monit Comput ; 36(1): 71-79, 2022 02.
Article in English | MEDLINE | ID: mdl-34191253

ABSTRACT

Continuous monitoring of the respiratory rate is crucial in an acute care setting. Contact respiratory monitoring modalities such as capnography and thoracic impedance pneumography are prone to artifacts, causing false alarms. Moreover, their cables can restrict patient behavior or interrupt patient care. A microwave Doppler sensor is a novel non-contact continuous respiratory rate monitor. We compared respiratory rate measurements performed with a microwave Doppler sensor mounted on the ceiling of an intensive care unit with those obtained by conventional methods in conscious and spontaneously breathing patients. Participants' respiratory rate was simultaneously measured by visual counting of chest wall movements for 60 s; a microwave Doppler sensor; capnography, using an oxygen mask; and thoracic impedance pneumography, using electrocardiogram electrodes. Bland-Altman analysis for repeated measures was performed to calculate bias and 95% limits of agreement between the respiratory rate measured by visual counting (reference) and that measured by each of the other methods. Among 52 participants, there were 336 (microwave Doppler sensor), 275 (capnography), and 336 (thoracic impedance pneumography) paired respiratory rate data points. Bias (95% limits of agreement) estimates were as follows: microwave Doppler sensor, 0.3 (- 6.1 to 6.8) breaths per minute (bpm); capnography, - 1.3 (- 8.6 to 6.0) bpm; and thoracic impedance pneumography, 0.1 (- 4.4 to 4.7) bpm. Compared to visual counting, the microwave Doppler sensor showed small bias; however, the limits of agreement were similar to those observed in other conventional methods. Our monitor and the conventional ones are not interchangeable with visual counting.Trial registration number: UMIN000032021, March/30/2018.


Subject(s)
Microwaves , Respiratory Rate , Capnography/methods , Humans , Intensive Care Units , Monitoring, Physiologic/methods
9.
J Intensive Care ; 9(1): 59, 2021 Oct 07.
Article in English | MEDLINE | ID: mdl-34615558

ABSTRACT

BACKGROUND: Trans-jejunal nutrition via a post-pyloric enteral feeding tube has a low risk of aspiration or reflux; however, placement of the tube using the blind method can be difficult. Assistive devices, such as fluoroscopy or endoscopy, are useful but may not be suitable for patients with hemodynamic instability or severe respiratory failure. The aim of this study was to explore factors associated with first-pass success in the blind placement of post-pyloric enteral feeding tubes in critically ill patients. METHODS: Data were obtained retrospectively from the medical records of adult patients who had a post-pyloric enteral feeding tube placed in the intensive care unit between January 1, 2012, and December 31, 2018. Logistic regression analysis was performed to assess the association between first-pass success and the independent variables. For logistic regression analysis, the following 13 variables were defined as independent variables: age, sex, height, fluid balance from baseline, use of sedatives, body position during the procedure, use of cardiac assist devices, use of prokinetic agents, presence or absence of intestinal peristalsis, postoperative cardiovascular surgery, use of renal replacement therapy, serum albumin levels, and position of the greater curvature of the stomach in relation to spinal levels L1 - L2. RESULTS: Data obtained from 442 patients were analyzed. The first-pass success rate was 42.8% (n = 189). Logistic regression analysis demonstrated that the position of the greater curvature of the stomach cephalad to L1 - L2 was only associated with successful placement (odds ratio for first-pass success, 0.62; 95% confidence interval: 0.40 - 0.95). CONCLUSIONS: In critically ill patients, the position of the greater curvature of the stomach caudal to L1 - L2 may be associated with a lower first-pass success rate of the blind method for post-pyloric enteral feeding tube placement. Further studies are needed to verify our results because the position of the stomach was estimated by radiographs after enteral feeding tube placement. TRIAL REGISTRATION: University Hospital Medical Information Network Clinical Trials Registry (UMIN000036549; April 20, 2019).

10.
J Intensive Care ; 9(1): 42, 2021 Jun 01.
Article in English | MEDLINE | ID: mdl-34074343

ABSTRACT

Since the start of the coronavirus disease 2019 (COVID-19) pandemic, it has remained unknown whether conventional risk prediction tools used in intensive care units are applicable to patients with COVID-19. Therefore, we assessed the performance of established risk prediction models using the Japanese Intensive Care database. Discrimination and calibration of the models were poor. Revised risk prediction models are needed to assess the clinical severity of COVID-19 patients and monitor healthcare quality in ICUs overwhelmed by patients with COVID-19.

11.
J Intensive Care ; 9(1): 18, 2021 Feb 15.
Article in English | MEDLINE | ID: mdl-33588956

ABSTRACT

BACKGROUND: The Acute Physiology and Chronic Health Evaluation (APACHE) III-j model is widely used to predict mortality in Japanese intensive care units (ICUs). Although the model's discrimination is excellent, its calibration is poor. APACHE III-j overestimates the risk of death, making its evaluation of healthcare quality inaccurate. This study aimed to improve the calibration of the model and develop a Japan Risk of Death (JROD) model for benchmarking purposes. METHODS: A retrospective analysis was conducted using a national clinical registry of ICU patients in Japan. Adult patients admitted to an ICU between April 1, 2018, and March 31, 2019, were included. The APACHE III-j model was recalibrated with the following models: Model 1, predicting mortality with an offset variable for the linear predictor of the APACHE III-j model using a generalized linear model; model 2, predicting mortality with the linear predictor of the APACHE III-j model using a generalized linear model; and model 3, predicting mortality with the linear predictor of the APACHE III-j model using a hierarchical generalized additive model. Model performance was assessed with the area under the receiver operating characteristic curve (AUROC), the Brier score, and the modified Hosmer-Lemeshow test. To confirm model applicability to evaluating quality of care, funnel plots of the standardized mortality ratio and exponentially weighted moving average (EWMA) charts for mortality were drawn. RESULTS: In total, 33,557 patients from 44 ICUs were included in the study population. ICU mortality was 3.8%, and hospital mortality was 8.1%. The AUROC, Brier score, and modified Hosmer-Lemeshow p value of the original model and models 1, 2, and 3 were 0.915, 0.062, and < .001; 0.915, 0.047, and < .001; 0.915, 0.047, and .002; and 0.917, 0.047, and .84, respectively. Except for model 3, the funnel plots showed overdispersion. The validity of the EWMA charts for the recalibrated models was determined by visual inspection. CONCLUSIONS: Model 3 showed good performance and can be adopted as the JROD model for monitoring quality of care in an ICU, although further investigation of the clinical validity of outlier detection is required. This update method may also be useful in other settings.

12.
Allergol Int ; 70(2): 229-234, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33279401

ABSTRACT

BACKGROUND: Stevens-Johnson syndrome (SJS) and toxic epidermal necrolysis (TEN) are rare but life-threatening disorders characterized by widespread epidermal necrosis of the skin and mucosa. The severity-of-illness scoring system for TEN (SCORTEN) was widely used since 2000 as a standard prognostic tool consisting of seven clinical values. METHODS: To evaluate the prognosis using current treatments and risk factors for mortality, we retrospectively analyzed 59 cases of TEN, including SJS/TEN overlap treated in two university hospitals from January 2000 to March 2020. RESULTS: The mortality rate of TEN was 13.6% (8/59). All patients treated with high-dose steroid administration in combination with plasma exchange and/or immunoglobulin therapy recovered. Logistic regression analysis showed nine clinical composite scores, namely: heart rate (≧120 bpm), malignancy present, percentage of body surface area with epidermal detachment (>10%), blood urea nitrogen (>28 mg/dL), serum bicarbonate level (<20 mEq/L), serum glucose level (>252 mg/dL), age (≧71 years), the interval between disease onset and treatment initiation at the specialty hospital (≧8 days), and respiratory disorder within 48 h after admission. The receiver operating characteristic curves confirmed a high potential for predicting the prognosis of TEN. CONCLUSIONS: Recent developments in treatment strategies have contributed to the improved prognosis of TEN patients. A modified severity scoring model composed of nine scores may be helpful in the prediction of TEN prognosis in recent patients. Further large-scale studies are needed to confirm mortality findings to improve prognostication in patients with TEN.


Subject(s)
Stevens-Johnson Syndrome/mortality , Adolescent , Adrenal Cortex Hormones/therapeutic use , Adult , Aged , Aged, 80 and over , Anti-Bacterial Agents/adverse effects , Anti-Inflammatory Agents, Non-Steroidal/adverse effects , Anticonvulsants/adverse effects , Child , Child, Preschool , Cohort Studies , Female , Humans , Japan/epidemiology , Male , Middle Aged , Prognosis , Risk Factors , Severity of Illness Index , Stevens-Johnson Syndrome/drug therapy , Young Adult
13.
Med Devices (Auckl) ; 13: 205-211, 2020.
Article in English | MEDLINE | ID: mdl-32765126

ABSTRACT

BACKGROUND: Precise control of tidal volume is one of the keys in limiting ventilator-induced lung injury and ensuring adequate ventilation in mechanically ventilated neonates. The aim of the study was to compare the tidal volume (mVT) measured from the expiratory limb of the ventilator with the actual tidal volume (aVT) that would be delivered to the patient using a lung model to simulate a neonate. METHODS: This study was conducted using the ASL5000 lung simulator. Three combinations of parameters were set: resistance (cmH2O/L/sec) and compliance (mL/cmH2O) of 50 and 2 (Group 1), 100 and 1 (Group 2), and 150 and 0.5 (Group 3), respectively. The ASL5000 was connected to each of the ventilators including one anesthesia machine ventilator (Drager Fabius GS) and two ICU ventilators (Servo-i Universal and Evita Infinity V500). Each ventilator was evaluated with a set tidal volume of 30 mL (sVT) and a respiratory rate of 25 breathes/minute in both the volume-controlled ventilation (VCV) and dual-controlled ventilation (DCV) modes. RESULTS: The discrepancies between sVT, mVT and aVT were highest with the Fabius anesthesia machine ventilator and increased in the simulated lung injury groups. When comparing the ICU ventilators, the difference was greater the Servo-i and increased when using the DCV mode and with simulated lung injury. CONCLUSION: Accurate tidal volumes were achieved only with the Infinity ICU ventilator. This was true regardless of mode of ventilation and even during simulated lung injury.

14.
J Intensive Care ; 8: 17, 2020.
Article in English | MEDLINE | ID: mdl-32082581

ABSTRACT

A high mortality rate is found among septic patients with disseminated intravascular coagulation (DIC). Anticoagulants have been used for treating septic DIC especially in Japanese clinical settings; however, their effectiveness is quite controversial across studies. According to several randomized controlled trials and meta-analyses, antithrombin and recombinant thrombomodulin had no therapeutic benefit in the treatment of sepsis. However, the majority of the previous research did not discuss "septic DIC" but simply "sepsis", and some reviews showed that anticoagulants were benefit only in septic DIC. Although immunothrombosis plays an important role in early host defense, it can lead to DIC and organ failure if dysregulated. Therefore, we advocate anticoagulant therapies might have beneficial effects, but research on optimal patient selection is currently lacking.

15.
J Investig Med ; 68(2): 392-396, 2020 02.
Article in English | MEDLINE | ID: mdl-31562229

ABSTRACT

While low-risk patients who undergo elective surgery can tolerate low hematocrit levels, the benefits of higher hematocrit levels might outweigh the risk of transfusion in high-risk patients. Therefore, this study aimed to evaluate the effects of perioperative hematocrit levels on mortality in patients requiring prolonged mechanical ventilation (PMV) after a cardiovascular surgery. This single-center retrospective cohort study was conducted on 172 patients who underwent cardiovascular surgery with cardiopulmonary bypass or off-pump coronary artery bypass grafting and required PMV for ≥72 hours in the intensive care unit (ICU) from 2008 to 2012 at the Yokohama City University Medical Center in Yokohama, Japan. Patients were classified according to hematocrit levels on ICU admission: high (≥30%) and low (<30%) groups. Of 172 patients, 86 were included to each of the low-hematocrit and high-hematocrit groups, with median hematocrit levels (first to third quartiles) of 27.4% (25.4%-28.7%) and 33.0% (31.3%-35.5%), respectively. The difference in survival rates was significant between the two groups using the log-rank test (HR 0.55, 95% CI 0.32 to 0.95, p=0.033). Cox regression analysis revealed that ≥30% increase in hematocrit levels on ICU admission was significantly associated with decreased long-term mortality (HR 0.40, 95% CI 0.20 to 0.80, p=0.0095). Lower hematocrit levels on ICU admission was a risk factor for increased long-term mortality, and higher hematocrit levels might outweigh the risk of transfusion in patients requiring PMV after a cardiovascular surgery.


Subject(s)
Anemia/blood , Cardiovascular Surgical Procedures/trends , Hematocrit/trends , Postoperative Complications/blood , Respiration, Artificial/trends , Aged , Anemia/complications , Anemia/diagnosis , Cardiovascular Surgical Procedures/adverse effects , Cohort Studies , Female , Humans , Male , Middle Aged , Postoperative Complications/etiology , Preoperative Care/trends , Respiration, Artificial/adverse effects , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
16.
PLoS One ; 14(7): e0219511, 2019.
Article in English | MEDLINE | ID: mdl-31291340

ABSTRACT

BACKGROUND: ClearSight is a noninvasive arterial blood pressure monitor, but it remains unknown whether it is affected by the state of perfusion to the fingers. We investigated whether the lower perfusion index (PI) measured with a pulse oximeter, which reflects finger perfusion, would affect the agreement between arterial pressures measured with ClearSight versus those obtained with an arterial catheter. METHODS: Paired arterial pressure data (ClearSight and arterial catheter-based pressures) and PI values were prospectively obtained from 30 patients undergoing major abdominal surgery. The primary outcome was standard deviation (SD) of the bias (precision) of blood pressure between ClearSight and arterial catheter. The ratio of the adjusted SD of the bias between PI≤1 and PI>1 was calculated using the linear mixed-effects model. The secondary outcomes were the bias and the limits of agreement (LOA) between the two devices (repeated measures Bland-Altman analysis). RESULTS: We analyzed 6312 paired data points. The adjusted SD of bias in PI ≤1 compared with those in PI >1 was 1.4-fold (95% confidence interval: 1.3- to 1.4-fold) for systolic arterial pressure, 1.5-fold (95% confidence interval: 1.3- to 1.6-fold) for diastolic arterial pressure, and 1.3-fold (95% confidence interval: 1.2- to 1.5-fold) for mean arterial pressure. The bias (LOA) were as follows: systolic arterial pressure in the PI ≤1 and PI >1 groups, -3.5 (-35.4 to 28.4) mmHg and 2.2 (-19.9 to 24.3) mmHg, respectively; diastolic arterial pressure in the PI ≤1 and PI >1 groups, 13.1 (-5.1 to 31.3) mmHg and 9.0, (-2.6 to 20.6) mmHg, respectively; and mean arterial pressure in the PI ≤1 and PI >1 groups, 8.7 (-11.3 to 28.7) mmHg and 7.6 (-6.2 to 21.3) mmHg, respectively. CONCLUSIONS: PI ≤1 was associated with a large SD of the bias between the devices. The PI value could be a real-time indicator of ClearSight precision.


Subject(s)
Arterial Pressure , Blood Pressure Determination/instrumentation , Monitoring, Intraoperative/instrumentation , Oximetry/instrumentation , Perfusion Index/instrumentation , Aged , Catheterization, Peripheral/instrumentation , Female , Hepatectomy , Humans , Male , Pancreaticoduodenectomy , Prospective Studies , Vascular Access Devices
17.
J Thorac Dis ; 11(4): 1223-1232, 2019 Apr.
Article in English | MEDLINE | ID: mdl-31179064

ABSTRACT

BACKGROUND: The rapid shallow breathing index (RSBI) is used clinically to help predict a patient's likelihood of successful liberation from mechanical ventilation (MV). However, the traditional threshold (<105 breaths/min/L) may underperform in patients with chronic obstructive pulmonary disease (COPD). We sought to determine the optimal RSBI threshold for COPD patients to improve the diagnostic accuracy for predicting successful ventilator liberation. METHODS: This was a prospective observational multicenter study of COPD patients [according to Global initiative for Chronic Obstructive Lung Disease (GOLD) criteria] admitted to the Medical ICUs of eight academic medical centers. All patients were intubated for hypercapnic respiratory failure and met the American Thoracic Society/European Respiratory Society guidelines to participate in a weaning trial. Ventilator weaning was conducted according to a defined protocol. RSBI was measured through the ventilator after 120 minutes of spontaneous breathing trial (SBT). RESULTS: Ninety patients were included (39 males and 51 females). Forty-three patients (48%) were successfully extubated whereas 47 patients (52%) failed extubation. Significant differences were observed between groups for duration-of-intubation [duration of intubation (DoI); P<0.0001], spontaneous tidal volume (VT) (P=0.03), and the ratio of dynamic-to-static compliance (P=0.005). The RSBI threshold of ≤85 breaths/min/L performed best: area under curve (AUC) receiver operating characteristic (ROC) curves 0.91, sensitivity 95.6%, specificity 90.4%, positive predictive value (PPV) 95.5%, and negative predictive value (NPV) 90.6%., positive likelihood ratio (LR+) 5.48, negative likelihood ratio (LR-) 0.25, and the diagnostic accuracy 91.7%. In post-ROC analyses, DoI and hospital length-of-stay (LOS) did not impact performance. CONCLUSIONS: In COPD patients intubated with hypercapnia, RSBI ≤85 breaths/min/L outperformed the widely used threshold <105 breaths/min/L, yielding a 95.5% probability of extubation success, independent of ventilation duration or hospital LOS.

18.
J Healthc Eng ; 2018: 9615264, 2018.
Article in English | MEDLINE | ID: mdl-29991996

ABSTRACT

Background: We previously reported a tele-anesthesia system that connected Sado General Hospital (SGH) to Yokohama City University Hospital (YCUH) using a dedicated virtual private network (VPN) that guaranteed the quality of service. The study indicated certain unresolved problems, such as the high cost of constantly using a dedicated VPN for tele-anesthesia. In this study, we assessed whether use of a best-effort system affects the safety and cost of tele-anesthesia in a clinical setting. Methods: One hundred patients were enrolled in this study. We provided tele-anesthesia for 65 patients using a guaranteed transmission system (20 Mbit/s; guaranteed, 372,000 JPY per month: 1 JPY = US$0.01) and for 35 patients using a best-effort system (100 Mbit/s; not guaranteed, 25,000 JPY per month). We measured transmission speed and number of commands completed from YCUH to SGH during tele-anesthesia with both transmission systems. Results: In the guaranteed system, anesthesia duration was 5780 min (88.9 min/case) and surgical duration was 3513 min (54.0 min/case). In the best-effort system, anesthesia duration was 3725 min (106.4 min/case) and surgical duration was 2105 min (60.1 min/case). The average transmission speed in the best-effort system was 17.3 ± 3.8 Mbit/s. The system provided an acceptable delay time and frame rate in clinical use. All commands were completed, and no adverse events occurred with both systems. Discussion: In the field of tele-anesthesia, using a best-effort internet VPN system provided equivalent safety and efficacy at a better price as compared to using a guaranteed internet VPN system.


Subject(s)
Anesthesiology/economics , Anesthesiology/methods , Internet/economics , Telemedicine/economics , Telemedicine/methods , Aged , Anesthetics/administration & dosage , Female , Health Care Costs , Hospitals , Humans , Japan , Male , Middle Aged , Nurses , Patient Safety , Quality of Health Care , User-Computer Interface
19.
J Anesth ; 32(4): 539-546, 2018 08.
Article in English | MEDLINE | ID: mdl-29789931

ABSTRACT

PURPOSE: The aim of this study was to examine the relationship between FFP (fresh frozen plasma)/pRBC (packed red blood cell) transfusion ratio and outcomes in patients undergoing cardiovascular surgery. METHODS: This is a single center retrospective cohort study performed in a cardiovascular center. Patients undergoing cardiovascular surgery between January 2012 and October 2016 with or without massive transfusion (n = 1453). Patients' outcomes were compared based on FFP/pRBC transfusion ratio (FFP/pRBC > 1 or FFP/pRBC ≤ 1). RESULTS: In hospital mortality and rate of stroke and myocardial infarction was significantly higher in patients with less than 1 of FFP/pRBC transfusion ratio only in patients with massive transfusion (3.0 vs 8.8%, p = 0.001; 0.7 vs 6.4%, p < 0.001; 1.0 vs 3.2%, p = 0.047, respectively). CONCLUSIONS: Higher FFP/RBC ratio was associated with reduced risk of death, stroke and myocardial infarction only in patients with cardiovascular surgery receiving massive transfusion. Clinicians should be aware that judicious FFP replacement plays a critical role in the successful management of massive transfusion in cardiac surgery.


Subject(s)
Blood Transfusion/methods , Cardiac Surgical Procedures/methods , Erythrocyte Transfusion , Plasma , Aged , Cardiac Surgical Procedures/mortality , Cohort Studies , Female , Hospital Mortality , Humans , Male , Middle Aged , Retrospective Studies
20.
J Anesth ; 32(2): 160-166, 2018 04.
Article in English | MEDLINE | ID: mdl-29330638

ABSTRACT

PURPOSE: Hyperglycemia is a common issue in infants after cardiac surgery for congenital heart disease. Poor glycemic control is suspected to be associated with adverse postoperative outcomes. This study was performed to investigate clinical factors contributing to hyperglycemia in the perioperative period in infats. METHODS: A total of 69 infants (aged 1-12 months) who were admitted to Yokohama City University Hospital Intensive Care Unit (ICU) after surgical repair of congenital heart diseases with cardiopulmonary bypass (CPB) were retrospectively analysed. Hyperglycemia was defined as blood glucose ≥ 250 mg/dL on ICU admission. Clinical background, operative factors, and postoperative factors were compared between the hyperglycemic and non-hyperglycemic groups. Additionally, multivariate analysis was performed to identify factors contributing to hyperglycemia. RESULTS: Nineteen (27.5%) and 50 (72.5%) infants were classified into the hyperglycemic and non-hyperglycemic groups, respectively. Hyperglycemic infants were significantly younger, shorter, and weighed less, with a higher rate of chromosomal abnormalities. Intraoperatively, they also experienced longer CPB and surgery times and had higher peak lactate levels and higher inotropic requirements. Hyperglycemia was related to longer mechanical ventilation and longer ICU stays. Multivariate analysis detected intraoperative hyperglycemia, longer CPB time, younger age and chromosomal abnormality as significant factors. CONCLUSION: Adding to hyperglycemia during the operation, longer CPB time younger age and chromosomal abnormality were identified as predictors of high blood glucose levels at ICU admission.


Subject(s)
Cardiac Surgical Procedures/methods , Cardiopulmonary Bypass/methods , Hyperglycemia/epidemiology , Postoperative Complications/epidemiology , Blood Glucose/metabolism , Cardiopulmonary Bypass/adverse effects , Case-Control Studies , Female , Heart Defects, Congenital/surgery , Humans , Infant , Intensive Care Units , Male , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...