Rev Sci Instrum ; 92(7): 073502, 2021 Jul 01.
Article in English | MEDLINE | ID: mdl-34340413

ABSTRACT

A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 µm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.

3.
Rev Sci Instrum ; 89(10): 10G120, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399783

ABSTRACT

A new tool has been developed to calculate the spectral, spatial, and temporal responses of multi-energy soft x-ray (ME-SXR) pinhole cameras for arbitrary plasma densities (n e,D), temperature (T e), and impurity densities (n Z). ME-SXR imaging provides a unique opportunity for obtaining important plasma properties (e.g., T e, n Z, and Z eff) by measuring both continuum and line emission in multiple energy ranges. This technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently. Simulations assuming a tangential geometry and DIII-D-like plasmas (e.g., n e,0 ≈ 8 × 1019 m-3 and T e,0 ≈ 2.8 keV) for various impurity (e.g., C, O, Ar, Ni, and Mo) density profiles have been performed. The computed brightnesses range from few 102 counts pixel-1 ms-1 depending on the cut-off energy thresholds, while the maximum allowable count rate is 104 counts pixel-1 ms-1. The typical spatial resolution in the mid-plane is ≈0.5 cm with a photon-energy resolution of 500 eV at a 500 Hz frame rate.

4.
Rev Sci Instrum ; 89(10): 10G116, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399822

ABSTRACT

A multi-energy soft x-ray pinhole camera has been designed and built for the Madison Symmetric Torus reversed field pinch to aid the study of particle and thermal-transport, as well as MHD stability physics. This novel imaging diagnostic technique combines the best features from both pulse-height-analysis and multi-foil methods employing a PILATUS3 x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. Further improvements implemented on the new cooled systems allow a maximum count rate of 10 MHz per pixel and sensitivity to the strong Al and Ar emission between 1.5 and 4 keV. The local x-ray emissivity will be measured in multiple energy ranges simultaneously, from which it is possible to infer 1D and 2D simultaneous profile measurements of core electron temperature and impurity density profiles with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. The expected time and space resolutions will be 2 ms and <1 cm, respectively.

5.
Cytopathology ; 29(4): 349-354, 2018 08.
Article in English | MEDLINE | ID: mdl-29723910

ABSTRACT

INTRODUCTION: The current study aimed to compare cytology using SurePath® (SP)-LBC and biliary tissue histology (BTH) for the diagnosis of biliary disease. METHODS: Between January 2014 and December 2016, 57 patients underwent endoscopic retrograde cholangiopancreatography for the diagnosis of biliary disease. Biliary cytological samples were processed using SP-LBC and subsequently BTH was performed. A final diagnosis was confirmed by surgery (23 malignant cases) and clinical follow-up (34 benign and malignant cases): 18 extrahepatic cholangiocarcinoma; 17 intrahepatic/hilar cholangiocarcinoma (intra/H-CC); eight other malignant disease; and 14 benign biliary disease. The diagnoses made using SP-LBC and BTH were classified into four categories: (1) benign; (2) indeterminate; (3) suspicious for malignancy/malignant; and (4) inadequate. In addition, diagnostic accuracy was compared between SP-LBC and BTH. RESULTS: Although 23% (13/57) of BTH samples were classified as inadequate, all SP-LBC cases were classified as adequate. Among 43 malignant cases, 11 normal, four indeterminate and 28 suspicious for malignancy/malignant were found using SP-LBC (26%, 9% and 65%, respectively), in contrast to 10 inadequate, nine normal, 10 indeterminate and 14 suspicious for malignancy/malignant observed using BTH (23%, 21%, 23%, and 33%, respectively). The identification of malignant cells was strikingly different between SP-LBC and BTH. Furthermore, limited to intra/H-CC, accuracy was significantly higher using SP-LBC than using BTH (P < .001). CONCLUSIONS: SP-LBC of the biliary tract is a useful and reliable method for diagnosing biliary malignant disease and has an advantage over BTH for detecting malignant cells and accurately diagnosing intra/H-CC.


Subject(s)
Bile Duct Neoplasms/pathology , Cholangiocarcinoma/pathology , Cytodiagnosis , Adult , Aged , Aged, 80 and over , Bile Duct Neoplasms/diagnostic imaging , Cholangiocarcinoma/diagnostic imaging , Cholangiopancreatography, Endoscopic Retrograde , Female , Humans , Male , Middle Aged
6.
Cytopathology ; 29(2): 150-155, 2018 04.
Article in English | MEDLINE | ID: mdl-29363841

ABSTRACT

INTRODUCTION: The aim of this study was to examine whether a combined test using both cell sediment and supernatant cytology cell-free DNA (ccfDNA) is more useful in detecting EGFR mutation than using cell sediment DNA or supernatant ccfDNA alone in pleural effusion of lung cancer patients. METHODS: A total of 74 lung adenocarcinoma patients with paired samples between primary tumour and corresponding metastatic tumour with both cell sediment and supernatant ccfDNA of pleural effusion cytology were enrolled in this study. Cell sediment and supernatant ccfDNA were analysed separately for EGFR mutations by polymerase chain reaction. RESULTS: Out of 45 patients with mutant EGFR in primary tumours, EGFR mutations were detected in 23 cell sediments of corresponding metastases (sensitivity; 51.1%) and 20 supernatant ccfDNA corresponding metastases (sensitivity; 44.4%). By contrast, the combined test detected EGFR mutations in 27 corresponding metastases (sensitivity; 60.0%), and had a higher sensitivity than the cell sediment or the supernatant ccfDNA alone (P < .05). Out of 45 patients with mutant EGFR, 24, three and 18 were cytologically diagnosed as positive, atypical or negative, respectively. The detection rate in the combined test was highest (95.8%) in the positive group, and mutant EGFR was also detected in four of 18 samples (22.2%) in the negative group. CONCLUSIONS: A combined test using both cell sediment DNA and supernatant ccfDNA samples increases the concordance rate of EGFR mutations between primary tumour and corresponding metastases. Our findings indicate that supernatant ccfDNA is useful even in cases where the cytological diagnosis is negative.


Subject(s)
Circulating Tumor DNA , Lung Neoplasms/genetics , Neoplasm Proteins/genetics , Pleural Effusion, Malignant/genetics , Polymerase Chain Reaction/methods , Aged , Aged, 80 and over , Circulating Tumor DNA/genetics , Circulating Tumor DNA/isolation & purification , DNA Mutational Analysis/methods , ErbB Receptors/genetics , Female , Humans , Lung Neoplasms/diagnosis , Lung Neoplasms/metabolism , Lung Neoplasms/pathology , Male , Middle Aged , Pleural Effusion, Malignant/diagnosis , Pleural Effusion, Malignant/metabolism , Pleural Effusion, Malignant/pathology
7.
Rev Sci Instrum ; 88(9): 093502, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28964174

ABSTRACT

After several experimental campaigns in the Kyushu University Experiment with Steady-state Spherical Tokamak (QUEST), the originally stainless steel plasma-facing wall (PFW) becomes completely covered with a deposited film composed of mixture materials, such as iron, chromium, carbon, and tungsten. In this work, an innovative colorimetry-based method was developed to measure the thickness of the deposited film on the actual QUEST wall. Because the optical constants of the deposited film on the PFW were position-dependent and the extinction coefficient k1 was about 1.0-2.0, which made the probing light not penetrate through some thick deposited films, the colorimetry method developed can only provide a rough value range of thickness of the metal-containing film deposited on the actual PFW in QUEST. However, the use of colorimetry is of great benefit to large-area inspections and to radioactive materials in future fusion devices that will be strictly prohibited from being taken out of the limited area.

8.
Rev Sci Instrum ; 87(9): 093502, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27782603

ABSTRACT

This paper evaluates the accuracy of electron temperature measurements and relative transmissivities of double-pass Thomson scattering diagnostics. The electron temperature (Te) is obtained from the ratio of signals from a double-pass scattering system, then relative transmissivities are calculated from the measured Te and intensity of the signals. How accurate the values are depends on the electron temperature (Te) and scattering angle (θ), and therefore the accuracy of the values was evaluated experimentally using the Large Helical Device (LHD) and the Tokyo spherical tokamak-2 (TST-2). Analyzing the data from the TST-2 indicates that a high Te and a large scattering angle (θ) yield accurate values. Indeed, the errors for scattering angle θ = 135° are approximately half of those for θ = 115°. The method of determining the Te in a wide Te range spanning over two orders of magnitude (0.01-1.5 keV) was validated using the experimental results of the LHD and TST-2. A simple method to provide relative transmissivities, which include inputs from collection optics, vacuum window, optical fibers, and polychromators, is also presented. The relative errors were less than approximately 10%. Numerical simulations also indicate that the Te measurements are valid under harsh radiation conditions. This method to obtain Te can be considered for the design of Thomson scattering systems where there is high-performance plasma that generates harsh radiation environments.

9.
Rev Sci Instrum ; 87(4): 043503, 2016 04.
Article in English | MEDLINE | ID: mdl-27131670

ABSTRACT

In TST-2 Ohmic discharges, local current is measured using a Rogowski probe by changing the angle between the local magnetic field and the direction of the hole of the Rogowski probe. The angular dependence shows a peak when the direction of the hole is almost parallel to the local magnetic field. The obtained width of the peak was broader than that of the theoretical curve expected from the probe geometry. In order to explain this disagreement, we consider the effect of sheath in the vicinity of the Rogowski probe. A sheath model was constructed and electron orbits were numerically calculated. From the calculation, it was found that the electron orbit is affected by E × B drift due to the sheath electric field. Such orbit causes the broadening of the peak in the angular dependence and the dependence agrees with the experimental results. The dependence of the broadening on various plasma parameters was studied numerically and explained qualitatively by a simplified analytical model.

10.
Rev Sci Instrum ; 85(11): 11D813, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430226

ABSTRACT

A Rogowski probe consisting of a small multi-layer Rogowski coil, five magnetic pick-up coils, and a Langmuir probe was developed to measure the local current density and its direction. It can be moved along the major radius and can be turned around its axis. This probe was used to measure the current density profile near the last closed flux surface of Ohmic plasmas in Tokyo Spherical Tokamak-2. The current density profile was measured successfully with a signal to noise ratio of greater than 20.

11.
Rev Sci Instrum ; 85(11): 11D846, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430259

ABSTRACT

The multi-pass Thomson scattering (TS) scheme enables obtaining many photons by accumulating multiple TS signals. The signal-to-noise ratio (SNR) depends on the accumulation number. In this study, we performed multi-pass TS measurements for ohmically heated plasmas, and the relationship between SNR and the accumulation number was investigated. As a result, improvement of SNR in this experiment indicated similar tendency to that calculated for the background noise dominant situation.

12.
Rev Sci Instrum ; 85(5): 056103, 2014 May.
Article in English | MEDLINE | ID: mdl-24880428

ABSTRACT

In multi-pass Thomson scattering (TS) scheme, a laser pulse makes multiple round trips through the plasma, and the effective laser energy is enhanced, and we can increase the signal-to-noise ratio as a result. We have developed a coaxial optical cavity in which a laser pulse is confined, and we performed TS measurements using the coaxial cavity in tokamak plasmas for the first time. In the optical cavity, the laser energy attenuation was approximately 30% in each round trip, and we achieved a photon number gain of about 3 compared with that obtained in the first round trip. In addition, the temperature measurement accuracy was improved by accumulating the first three round trip waveforms.

13.
Rev Sci Instrum ; 83(8): 083103, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22938270

ABSTRACT

Using an 8 × 8 channel photomultiplier tube assembly and a single Czerny-Turner monochromator, we have developed a novel Doppler spectroscopic system which can measure the time evolutions of spectral distribution of plasma emission from eight different lines of sight simultaneously. An optical lens system is employed to couple the output of the monochromator with the detector assembly, resulting in small cross-talks less than 5% in spatial distribution together with large magnification of up to 50 in wavelength direction. The suggested system yields cost-effective polychromatic measurements of eight spatial channels with uniform optical and electrical characteristics.

15.
Rev Sci Instrum ; 83(2): 023507, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22380091

ABSTRACT

This paper presents an experimental demonstration to determine electron temperature (T(e)) with unknown spectral sensitivity (transmissivity) in a Thomson scattering system. In this method, a double-pass scattering configuration is used and the scattered lights from each pass (with different scattering angles) are measured separately. T(e) can be determined from the ratio of the signal intensities without knowing a real chromatic dependence in the sensitivity. Note that the wavelength range for each spectral channel must be known. This method was applied to the TST-2 Thomson scattering system. As a result, T(e) measured from the ratio (T(e,r)) and T(e) measured from a standard method (T(e,s)) showed a good agreement with <∣T(e,r) - T(e,s)∣∕T(e,s)> = 7.3%.

16.
Interv Neuroradiol ; 16(4): 409-19, 2010 Dec.
Article in English | MEDLINE | ID: mdl-21162771

ABSTRACT

Arterial spin-labeling (ASL) magnetic resonance imaging (MRI) enables non-invasive acquisition of the brain perfusion information in cerebrovascular disease. We investigated hemodynamic changes in intracranial dural arteriovenous fistulas (DAVFs) using ASL-MRI. ASL-MRI by a Q2TIPS sequence on a 3.0-Tesla MRI was performed for three patients with Cognard's IIa+b type of DAVFs before and after treatment. Perfusion images obtained by ASL-MRI (ASL images) before treatment were visually compared with those by single-photon emission computed tomography images (SPECT images). Increasing rates of temporal changes of regional perfusion values in ASL images (ASL values) before and after treatment were also calculated. In all three patients, ASL images before treatment demonstrated high perfusion in regions around the shunting areas, where normal or low perfusion were detected on SPECT images; thus, ASL images might have demonstrated the abundant arterial shunting flow via the fistulas. On days eight to 20 after treatment, ASL values around the shunt areas remained the same or decreased, and those in the regions other than the shunt areas increased in all three patients. This might have been due to a combination of the following: a decrease in shunt flow volume, an amelioration of venous congestion, and a sustained an upward shift in the autoregulation of the brain perfusion pressure. All regional ASL values decreased on days 112 and 120 after treatment in two patients, which possibly reflects a reduction in the upward shift in autoregulation. ASL-MRI might be useful for identifying the hemodynamic behavior of DAVFs before and after treatment.


Subject(s)
Central Nervous System Vascular Malformations/diagnosis , Central Nervous System Vascular Malformations/physiopathology , Cerebrovascular Circulation/physiology , Magnetic Resonance Imaging/methods , Aged , Angiography, Digital Subtraction , Central Nervous System Vascular Malformations/therapy , Embolization, Therapeutic , Female , Homeostasis/physiology , Humans , Male , Middle Aged , Retrospective Studies , Spin Labels , Tomography, Emission-Computed, Single-Photon
17.
AJNR Am J Neuroradiol ; 31(9): 1713-8, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20466798

ABSTRACT

BACKGROUND AND PURPOSE: The "ivy" sign that is identified on FLAIR images in patients with Moyamoya disease is considered to be leptomeningeal collaterals. The aim of our study was to evaluate the correlation between postoperative decrease in ivy sign and cerebral hemodynamic status in the bypass-established hemisphere. MATERIALS AND METHODS: Twenty-two patients with Moyamoya disease were enrolled. Postoperative changes in the ivy sign on FLAIR images were examined in each patient after bypass surgery. The correlation between postoperative changes in the ivy sign and hemodynamic status was examined in 10 patients by using SPECT. RESULTS: Of the 22 preoperative ivy-positive patients, 21 showed decreased ivy signs on the operative side. Average intervals between the operation day and the date when the decreased or vanished ivy sign was first recognized were 157.6 days in patients who underwent direct bypass and 212.2 days in patients who underwent indirect bypass. A postoperative decrease in ivy signs was found to be significantly correlated with an improved hemodynamic status of the surgically treated hemisphere, resulting in a postoperative increase in regional vascular reserve and a decreased proportion of the misery perfusion area (P < .01). CONCLUSIONS: Postoperative changes in the ivy sign can be used as a marker for identifying improved hemodynamics and also for testing the effectiveness of cerebral revascularization.


Subject(s)
Cerebral Revascularization/methods , Cerebrospinal Fluid/cytology , Meninges/pathology , Moyamoya Disease/pathology , Moyamoya Disease/surgery , Adolescent , Adult , Aged , Child , Female , Humans , Male , Middle Aged , Prognosis , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome , Young Adult
18.
AJNR Am J Neuroradiol ; 30(9): 1709-16, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19713323

ABSTRACT

BACKGROUND AND PURPOSE: An ivy sign is considered to represent diffuse leptomeningeal collaterals found on fluid-attenuated inversion recovery (FLAIR) images of patients with Moyamoya disease. We evaluated the correlation between unilateral ivy proliferation in a hemisphere and cerebrovascular hemodynamic status to learn the clinical significance of the ivy sign. MATERIALS AND METHODS: A total of 35 patients with Moyamoya disease were included. Correlation between ivy dominance on FLAIR images and hemodynamic status with use of iodine 123 N-isopropyl-p-iodoamphetamine ((123)I-IMP) single-photon emission CT (SPECT) was evaluated. RESULTS: Distributional differences of ivy signs between both hemispheres were observed in 22 (64.7%) of 34 patients with a positive ivy sign, all of whom showed decreased vascular reserve/reactivity in the ivy-dominant hemisphere (IDH). The proportion of the stage II (misery perfusion) area to IDH was higher than that in the ivy less-dominant hemisphere (ILDH) in the quantitative analysis. The mean vascular reserve was lower in IDH than ILDH. There were 15 of 22 patients who had bypass surgery on IDH because of transient ischemic attack from ischemia of IDH. Patients with symmetric ivy distributions showed a variety of hemodynamic status. MR angiography (MRA) stage of IDH (2.95 +/- 0.39) was higher compared with ILDH (2.60 +/- 0.50; P < .05). Regional arteriocapillary circulation time ratio in IDH was longer compared with ILDH (P < .05). Ivy proliferation decreased in 10 (55.6%) of 18 patients who underwent bypass surgery during the follow-up period. CONCLUSIONS: Unilateral hemispheric ivy proliferation correlated highly with the existence of an ipsilateral decreased vascular reserve associated with the development of leptomeningeal collaterals in patients with Moyamoya disease.


Subject(s)
Brain/pathology , Magnetic Resonance Imaging/methods , Meninges/pathology , Moyamoya Disease/pathology , Adolescent , Adult , Cerebrospinal Fluid/cytology , Child , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Young Adult
19.
Rev Sci Instrum ; 79(10): 10E518, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044500

ABSTRACT

It is very important to investigate the confinement of alpha particles, which will be produced by nuclear reactions in ITER and fusion reactors. The pellet charge exchange (PCX) measurement is one of the most powerful methods because it can directly provide the profile of the alpha particle energy spectra in a plasma. In the large helical device, PCX using tracer encapsulated solid pellet (TESPEL) has been tried in many hydrogen and helium plasmas, including helium accelerated by using the cyclotron resonance heating. In the PCX, we use the compact neutral particle analyzer without simultaneous mass separation ability. The helium particle measurement can be achieved by the application of voltage in the condenser plate. The scattering of hydrogen particle is carefully considered during the estimation of the helium amount. The radial helium profiles can also be obtained by comparing four TESPEL injection shots with/without higher harmonic fast wave heating and at applied plate voltages for He or H, respectively.

20.
Rev Sci Instrum ; 79(10): 10E722, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044539

ABSTRACT

A wave detector, a newly designed magnetic probe, is installed in the large helical device (LHD). This wave detector is a 100-turn loop coil with electrostatic shield. Comparing a one-loop coil to this detector, this detector has roughly constant power coupling in the lower frequency range of 40 MHz, and it can easily detect magnetic wave in the frequency of a few megahertz. During high-harmonic fast wave heating, lower frequency waves (<10 MHz) were observed in the LHD for the first time, and for the power density threshold of lower frequency wave excitation (7.5 MHz) the power density of excited pumped wave (38.47 MHz) was approximately -46 dBmHz. These lower frequencies are kept constant for electron density and high energy particle distribution, and these lower frequency waves seem to be ion cyclotron waves caused by nonlinear wave-particle interaction, for example, parametric decay instability.