1.
Transplant Proc ; 38(9): 2968-70, 2006 Nov.
Article in English | MEDLINE | ID: mdl-17112876

ABSTRACT

Sequential or domino liver transplantation is a well-established procedure for patients with familial amyloidotic polyneuropathy (FAP). Donation for domino liver transplantation imposed the resection of the inferior vena cava along with the liver, requiring complete suprarenal vena cava clamping and usually the use of venovenous bypass. We describe a successful case in which it was possible to perform the FAP hepatectomy by the piggyback technique.


Subject(s)
Amyloid Neuropathies, Familial/surgery , Liver Transplantation/methods , Adult , Cadaver , Humans , Male , Tissue Donors , Treatment Outcome
2.
Sao Paulo Med J ; 117(6): 243-7, 1999 Nov 04.
Article in English | MEDLINE | ID: mdl-10625887

ABSTRACT

CONTEXT: High compliance endotracheal tubes cuffs are used to prevent gas leak and also pulmonary aspiration in mechanically ventilated patients. However, the use of the usual cuff inflation volumes may cause tracheal damage. OBJECTIVE: We tested the hypothesis that endotracheal tube cuff pressures are routinely high (above 40 cmH2O) in the Post Anesthesia Care Unit (PACU) or Intensive Care Units (ICU). DESIGN: Cross-sectional study. SETTING: Post anesthesia care unit and intensive care unit. PARTICIPANTS: We measured endotracheal tubes cuff pressure in 85 adult patients, as follows: G1 (n = 31) patients from the ICU; G2 (n = 32) patients from the PACU, after anesthesia with nitrous oxide; G3 (n = 22) patients from the PACU, after anesthesia without nitrous oxide. Intracuff pressure was measured using a manometer (Mallinckrodt, USA). Gas was removed as necessary to adjust cuff pressure to 30 cmH2O. MAIN MEASUREMENTS: Endotracheal tube cuff pressure. RESULTS: High cuff pressure (> 40 cmH2O) was observed in 90.6% patients of G2, 54.8% of G1 and 45.4% of G3 (P < 0.001). The volume removed from the cuff in G2 was higher than G3 (P < 0.05). CONCLUSION: Endotracheal tubes cuff pressures in ICU and PACU are routinely high and significant higher when nitrous oxide is used. Endotracheal tubes cuff pressure should be routinely measured to minimize tracheal trauma.


Subject(s)
Intubation, Intratracheal/adverse effects , Cross-Sectional Studies , Female , Humans , Intensive Care Units , Intubation, Intratracheal/instrumentation , Male , Middle Aged , Nitrous Oxide/administration & dosage , Pressure , Sex Distribution , Trachea/injuries