Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
J Orthop Sci ; 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38897850

ABSTRACT

BACKGROUND: Although various surgical methods are available for unstable distal clavicle fractures, consensus remains lacking on the optimal technique. Therefore, the present retrospective study aimed to compare the clavicle hook plate and Scorpion Plate® in terms of clinical outcomes and radiological findings for unstable distal clavicle fractures. METHODS: Fifty-seven patients with unstable distal clavicle fractures who underwent treatment using a clavicle hook plate (Group H; 28 patients) or Scorpion Plate® (Group S; 29 patients) were included in the present study. No patients received additional augmentation and all were followed-up for >1 year (mean follow-up, 28 months). Clinical outcomes were operation time, bleeding volume, complications, range of motion (ROM) at 6 months after surgery and final follow-up, and clinical scores (Constant-Murley score and University of California, Los Angeles (UCLA) shoulder score). Radiological outcomes assessed were coracoclavicular distance (CCD), difference in CCD between affected and non-affected sides (ΔCCD), and acromioclavicular subluxation ratio (%ACS) from plain X-rays. The χ2 test and Mann-Whitney U test were used to compare each outcome. RESULTS: Complications were seen in 3 shoulders (10.7%) in Group H. ROM was significantly worse in Group H at 6 months postoperatively, but no significant differences between groups were evident at final follow-up. Moreover, no significant differences in clinical outcomes were seen between groups. In terms of radiological results, Group H showed greater improvement in CCD and ΔCCD than Group S. Further, %ACS was significantly worse in Group S. CONCLUSIONS: The clavicle hook plate allows reconstruction of a more anatomical position than the Scorpion Plate®, but carries a greater risk of complications. Conversely, the Scorpion Plate® has a low risk of complications, but acromioclavicular subluxation remains. However, no significant differences in ROM or clinical outcomes were apparent at final follow-up.

2.
Trauma Case Rep ; 47: 100864, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37383026

ABSTRACT

Background: The artificial bone grafts are performed on the defect after reduction of the calcaneal fracture. Generally, it is an artificial bone graft with an implant, and there are a few reports of an artificial bone graft without an implant. Cases: We report three cases (42-year-old male, 67-year-old male, 21-year-old female) of a tongue-shaped calcaneal fracture treated using a cylindrical unidirectional porous ß-tricalcium phosphate artificial bone (Affinos®, Kurare co Ltd., Hyougo, Japan) to surgically repair bone defects after reduction. The bone defect is often observed when fracture is reduced in calcaneal fracture. There were significant bone defects, which were then fixed using Affinos® (forming a cylindrical shape block; diameter 10 mm x height 20 mm) to support the bone fragment, an artificial ß-tricalcium phosphate bone with a porosity of 57 % (pore size 25-300 µm), characterized by a novel unidirectional porous structure. Postoperative early rehabilitation started with partial load from 5 weeks after surgery and was full weight bearing at 9 weeks after surgery. There was no correction loss and good bone fusion was obtained. By 12 months postoperatively, patients were able to be walking without pain and absorption and bone fusion around the artificial bone were observed maintaining the morphology immediately after reduction. The result was a good clinical result of one excellent (92 points) and two good (81 and 84 points) 1 year after surgery in the postoperative AOFAS Ankle-Hindfoot Scale. Conclusion: Affinos® has a frost-like structure, which endows it with good tissue invasive properties because of the capillary effect. Moreover, it has excellent osteoconduction capability. In these 3 cases, Affinos® showed good strength, affinity, absorption, and bone substitution in a tongue-shaped calcaneal fracture. Further prospective studies are required to confirm our findings.

3.
J Orthop Trauma ; 36(6): e243-e249, 2022 06 01.
Article in English | MEDLINE | ID: mdl-34744153

ABSTRACT

OBJECTIVES: To evaluate the influence of posterior hook position on subacromial bone erosion during surgical treatment of distal clavicle fractures with locking compression plate clavicle hook plate (CHP). DESIGN: Single-center retrospective study. SETTING: Level V trauma center (university hospital). PATIENTS: Twenty-one patients (mean age, 45.8 years) treated with CHP were included. One, 3, 15, and 2 patients had Neer type I, IIa, IIb, and V fractures, respectively. INTERVENTION: Open reduction and internal fixation were performed with locking compression plate CHP. All implants were removed after a mean of 6.1 months postoperatively. MAIN OUTCOME MEASUREMENTS: Japanese Orthopaedic Association shoulder scores were used to assess recovery. Radiographically, the coracoclavicular distance was measured as the distance between the tip of the coracoid process and the undersurface of the clavicle. Three-dimensional computed tomography was performed to identify bone erosion at the hook tips after implant removal. The distance from the acromioclavicular joint center to the bone erosion was divided into 5 areas at 5-mm intervals, and the position and depth of bone erosion were measured in each area. RESULTS: The mean follow-up period was 17.4 months; mean ± SD Japanese Orthopaedic Association score was 75.9 ± 4.7 at the final follow-up, whereas the mean duration of bony union was 4.4 ± 1.0 (SD) months. Delayed bony union was observed in one patient, whereas a second surgery was required in another due to acromion cut-out. Radiography showed overreduction in 95% of cases. The correlation coefficient showed a difference between coracoclavicular distance and the position of bone erosion measured by CT (Rs = 0.32, P = 0.006). Erosion under the acromion surface was found in all patients. The depth of erosion correlated with the posterior hook position (Rs = 0.29, P = 0.023). CONCLUSIONS: Posterior hook tip placement increased the likelihood of bone erosion and complications due to overreduction. CHP should be set more anteriorly beneath the acromion to prevent complications. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Clavicle , Fractures, Bone , Bone Plates/adverse effects , Clavicle/diagnostic imaging , Clavicle/injuries , Clavicle/surgery , Fracture Fixation, Internal/methods , Fractures, Bone/diagnostic imaging , Fractures, Bone/etiology , Fractures, Bone/surgery , Humans , Middle Aged , Retrospective Studies , Treatment Outcome
4.
J Shoulder Elbow Surg ; 31(2): 359-366, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34450281

ABSTRACT

BACKGROUND: This study aimed to assess the long-term outcomes of the open modified inferior capsular shift procedure across more than 20 years in patients with traumatic anterior shoulder instability. METHODS: Participants in this study comprised 84 patients (86 shoulders; 67 men, 17 women). Mean follow-up was 28.0 years. We compared the recurrent instability rate after surgery, apprehension, revision rate, satisfaction, return to preinjury sporting activity, and patient background characteristics between recurrent and nonrecurrent groups. Twenty-seven patients who were examined directly were evaluated for differences in range of motion and muscle strength between affected and nonaffected sides. Clinical outcome scores used for this study were the Western Ontario Shoulder Instability Index and the Rowe score. RESULTS: Nine shoulders (10.5%) showed recurrent instability, as dislocation in 3 shoulders and subluxation in 6 shoulders, but no revisions were required. All patients with recurrent instability were males with new trauma. Three shoulders developed recurrent instability ≤5 years after surgery, and the remaining 6 shoulders showed recurrent instability >5 years after surgery. No significant differences in any patient characteristic were identified between the recurrent and nonrecurrent groups. Significant differences between affected and nonaffected sides were seen in the mean active range of motion or muscle strength for external rotation in the anatomic position or in 90° of abduction. Western Ontario Shoulder Instability Index and Rowe score were significantly worse in the recurrent group than in the nonrecurrent group. Patients reported that 84 shoulders (97.7%) were "much better." Most athletes (88.4%) had returned to sports activity at a level >70%. CONCLUSION: We investigated long-term outcomes of the open modified inferior capsular shift procedure for traumatic anterior shoulder instability. Our data suggest that recurrent instability might result from new trauma even if a long time has passed since the open modified inferior capsular shift procedure, so follow-up should be continued as long as possible after surgery. As in other reports, satisfaction was high and clinical scores were good. We thus believe this surgical method offers good results even after more than 20 years.


Subject(s)
Joint Instability , Shoulder Dislocation , Shoulder Joint , Female , Follow-Up Studies , Humans , Joint Instability/etiology , Joint Instability/surgery , Male , Range of Motion, Articular , Recurrence , Retrospective Studies , Shoulder , Shoulder Dislocation/surgery , Shoulder Joint/surgery , Treatment Outcome
5.
J Orthop Sci ; 26(6): 1094-1099, 2021 Nov.
Article in English | MEDLINE | ID: mdl-33176960

ABSTRACT

BACKGROUND: It is unknown whether locking or nonlocking superior plate fixation is better for managing displaced midshaft clavicle fractures. Therefore, we aimed to compare the clinical and radiographic outcomes of locking and nonlocking superior plate fixation of displaced midshaft clavicle fractures. METHODS: A total of 102 consecutive patients with displaced midshaft clavicle fractures (2B1 and 2B2 in Robinson classification) participated in this randomized controlled trial; 12 patients were excluded. Surgeries were performed using a 3.5-mm Locking Compression Plate (LCP) between 2007 and 2015. Patients were treated either with a locking plate (group L, n = 45) or a nonlocking plate (group N, n = 45). In both groups, the plates were fixed to the proximal and distal clavicle with two and/or three screws, respectively. The main outcome measures were complication rates, time to bone union, and Constant score. RESULTS: Forty-two patients in group L (mean age, 45.9 years) and 41 in group N (mean age, 43.6 years) were followed. The overall complication rates in groups L and N were 7.2% (three peri-implant fractures) and 7.3% (non-union, deformed plate, and peri-implant fracture), respectively (p = .98). The average time to union significantly differed between groups (L vs. N: 13.0 ± 4.1 vs. 17.5 ± 6.3 weeks; p < .01). However, the Constant score at the final follow-up was not significantly different between groups (L vs. N: 87.0 ± 12.3 vs. 89.8 ± 9.1). CONCLUSIONS: Similar complication rates and clinical results were found for locking and nonlocking superior plate fixation for displaced midshaft clavicle fractures. However, the time to bone union was shorter with the locking plate. This study suggests that both plating systems are effective for treating displaced midshaft clavicle fractures. LEVEL OF EVIDENCE: Therapeutic, level I.


Subject(s)
Fractures, Bone , Periprosthetic Fractures , Adult , Bone Plates , Clavicle/diagnostic imaging , Clavicle/surgery , Fracture Fixation, Internal , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Humans , Middle Aged , Prospective Studies , Treatment Outcome
7.
Regen Ther ; 9: 24-31, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30525072

ABSTRACT

INTRODUCTION: Using a rat model of nontraumatic early arthritis induced by intra-articular administration of low-dose monoiodoacetic acid (MIA), we transplanted allogeneic chondrocyte sheets and examined the effects on tissue repair. METHODS: MIA (0.2 mg/50 µl) was injected into the right knee of 20 male Wistar rats. Four weeks later, rats were randomly allocated into three groups: Group A was examined 4 weeks after administration of MIA; Group B, 8 weeks after MIA injection and chondrocyte sheet transplantation, and Group C, 8 weeks after MIA injection but without chondrocyte sheet transplantation. Allogeneic chondrocyte sheets were transplanted into the right knee of Group B rats. Pain was assessed as the weight distribution ratio of the damaged to undamaged limb. The OARSI score was used for histological scoring. RESULTS: The limb weight distribution ratio indicated significantly less pain in Group B. Histological scoring showed significant differences in cartilage repair and inhibition of the progression of cartilage degeneration between Groups B and C, but not between Groups A and B, or Groups A and C. CONCLUSIONS: These findings suggest that, in this rat model of nontraumatic early arthritis induced by low-dose MIA injection, allogeneic chondrocyte sheet transplantation induces cartilage repair and suppresses cartilage degeneration.

8.
J Orthop Trauma ; 31(7): S3, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28632663

ABSTRACT

OBJECTIVE: We examined the factors related to a reduction in the use of low-intensity pulsed ultrasound (LIPUS) for patients at both our hospital and other affiliated institutions. MATERIALS AND METHODS: Of 350 patients who used LIPUS at our and other affiliated institutions from May 2010 to April 2015, 279 (168 males, 111 females) were evaluated, after excluding mortalities and those with unexplained bone adhesion. Those patients with LIPUS compliance [calculated as: (number of days LIPUS was used/number of days LIPUS was available) × 100] below 80% were defined as the non-compliant group (170 patients), and those patients with a compliance rate of 80% or above were defined as the compliant group (109 patients). Factors related to a reduction in compliance were examined and included duration of use, age, sex, fracture side (right or left), and fracture site. RESULTS: The duration of use was longer in the non-compliant group compared with that in the compliant group (mean ± SD: 160 ± 118 days vs. 126 ± 81 days; P = 0.01), and the mean age was younger in the non-compliant group (42 ± 20 years vs. 50 ± 21 years; P = 0.002). Additionally, there was a higher ratio of females/males in the compliant group (60/49 vs. 120/50; P = 0.008). However, the side of the fracture was not significantly different between the groups (P = 0.449). Fractures of the forearm were more frequent in the non-compliant group than that in the compliant group (25/170 vs. 7/109; P = 0.003). DISCUSSION: The results suggest that the factors predictive of a reduction in the use of LIPUS are a long period of use, younger age, male gender, and use on fractures of the forearm.

SELECTION OF CITATIONS
SEARCH DETAIL
...