Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
Analyst ; 149(10): 2932-2941, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38590233

ABSTRACT

In this study, we successfully applied a transition-edge sensor (TES) spectrometer as a detector for microbeam X-ray measurements from a synchrotron X-ray light source in the hard X-ray region to determine uranium (U) distribution at the micro-scale and its chemical species in biotite obtained from a U mine. It is difficult to separate the fluorescent X-ray of the U Lα1 line at 13.615 keV from that of the Rb Kα line at 13.395 keV in the X-ray fluorescence spectrum with an energy resolution of approximately 220 eV using a conventional silicon drift detector (SDD). Meanwhile, the fluorescent X-rays of U Lα1 and Rb Kα were fully separated by a TES with 50 eV energy resolution at an energy of around 13 keV. The successful peak separation by the TES led to an accurate mapping analysis of trace U in micro-X-ray fluorescence measurements and a decrease in the signal-to-background ratio in micro-X-ray absorption near edge structure spectroscopy. Thus, it could be a powerful tool for studying the U distribution and speciation in various environmental samples.

2.
Anal Chim Acta ; 1240: 340755, 2023 Feb 01.
Article in English | MEDLINE | ID: mdl-36641142

ABSTRACT

Accurate determination of cerium (Ce) valence state is important for interpreting the Ce anomaly in geological archives for (paleo)redox reconstruction. However, the routine application of Ce L3-edge X-ray absorption near-edge structure (XANES) spectroscopy for detecting trace Ce in geological samples can often be restricted by coexisting titanium (Ti) due to the proximity of their fluorescence emission lines. Therefore, the signal-to-noise ratio of Ce L3-edge XANES spectra may not be sufficiently high for high-quality spectroscopic analysis. This study introduces a semi-quantitative approach appropriate for Ti-rich, Ce-dilute geological materials by synchrotron-based X-ray measurement at the Ce L2-edge. First, the results confirm that Ce L2-edge XANES spectra are able to avoid overlapping Ti Kß emissions and provide more reliable information on the Ce valence state in Ti-rich materials relative to L3-edge XANES. Moreover, the application of transition-edge sensor (TES) could reach the higher sensitivity with better energy resolution than conventional silicon drift detector (SDD) to detect fluorescence X-ray (Ce Lß1). The investigation on bauxites developed from the Columbia River Basalts shows that combining Ce L2-edge XANES and TES allows for resolving weak Ce fluorescence lines at the L2-edge from Ti-rich, Ce-dilute samples (Ti/Ce mass ratio up to ∼6000, tens of ppm Ce). The outcome emphasizes the practical possibility of investigating Ce redox state in Ti-rich geological samples.


Subject(s)
Cerium , Cerium/chemistry , Titanium , Aluminum Oxide , X-Ray Absorption Spectroscopy , Oxidation-Reduction
SELECTION OF CITATIONS
SEARCH DETAIL
...