Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Obstet Gynaecol ; 31(3): 213-6, 2011.
Article in English | MEDLINE | ID: mdl-21417642

ABSTRACT

Cervical length (by transvaginal sonography) was compared to Bishop's score (by digital examination of cervix) for prediction of pre-term birth in women with pre-term labour. The study group was 100 women with a singleton pregnancy with pre-term labour between 26-36 weeks' gestation. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of cervical length ≤2.5 cm ( by TVS) to predict delivery within 48 h and 7 days of admission were 62.5%, 89.5%, 65.2%, 88.3%, and, 60.0%, 96.9%, 91.3%, 81.8%, respectively. Similar values of Bishop's score ≥5 were 62.5%, 85.52%, 57.69%, 87.83%, and, 62.8%, 93.8%, 84.6%, 82.4%, respectively. To conclude, both Bishop's score ≥5 and reduced cervical length of ≤2.5 cm (by TVS) can predict the risk of pre-term delivery within 48 h or 7 days.


Subject(s)
Cervix Uteri/diagnostic imaging , Obstetric Labor, Premature/diagnostic imaging , Premature Birth/diagnosis , Adult , Female , Gestational Age , Humans , Pregnancy , Risk Factors , Tocolysis , Ultrasonography
2.
J Obstet Gynaecol ; 30(5): 451-5, 2010.
Article in English | MEDLINE | ID: mdl-20604645

ABSTRACT

The study group consisted of 100 women with a singleton pregnancy with pre-term labour between 26-36 weeks' gestation. Cervicovaginal secretions were collected for HCG assay and cervical length was measured by transvaginal sonography (TVS). These parameters were analysed to predict pre-term birth. The pre-term delivery rate was 55%; 24% delivered within 48 h and 11% within 7 days of admission. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of cervical length or=45 mIU/ml was the optimal cut-off, with a sensitivity, specificity, PPV and NPV for predicting delivery within 48 h and 7 days to be 95.8%, 73.7%, 53.5% and 98.2% and 85.7%, 80%, 69.8% and 91.2%, respectively. Combining either qualitative or quantitative HCG assay with cervical length significantly increased the sensitivity and NPV of cervical length alone for prediction of pre-term delivery both within 48 h and 7 days. It was concluded that increased cervicovaginal HCG and reduced cervical length predicted an increased risk of pre-term delivery in women with pre-term labour. Qualitative cervicovaginal HCG assay may be used as a bedside test to predict pre-term delivery within 48 h or within 7 days.


Subject(s)
Cervical Length Measurement , Cervix Uteri/diagnostic imaging , Obstetric Labor, Premature/diagnostic imaging , Adult , Chorionic Gonadotropin/metabolism , Female , Humans , Obstetric Labor, Premature/epidemiology , Obstetric Labor, Premature/metabolism , Predictive Value of Tests , Pregnancy , Pregnancy Outcome , Risk Factors , Sensitivity and Specificity , Vagina/metabolism , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...