Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Magn Reson Imaging ; 112: 100-106, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38971266

ABSTRACT

We aimed to determine the intra-site repeatability and cross-site reproducibility of T1 and T2* relaxation times and quantitative susceptibility (χ) values obtained through quantitative parameter mapping (QPM) at 3 T. This prospective study included three 3-T scanners with the same hardware and software platform at three sites. The brains of twelve healthy volunteers were scanned three times using QPM at three sites. Intra-site repeatability and cross-site reproducibility were evaluated based on voxel-wise and region-of-interest analyses. The within-subject coefficient of variation (wCV), within-subject standard deviation (wSD), linear regression, Bland-Altman plot, and intraclass correlation coefficient (ICC) were used for evaluation. The intra-site repeatability wCV was 11.9 ± 6.86% for T1 and 3.15 ± 0.03% for T2*, and wSD of χ at 3.35 ± 0.10 parts per billion (ppb). Intra-site ICC(1,k) values for T1, T2*, and χ were 0.878-0.904, 0.972-0.976, and 0.966-0.972, respectively, indicating high consistency within the same scanner. Linear regression analysis revealed a strong agreement between measurements from each site and the site-average measurement, with R-squared values ranging from 0.79 to 0.83 for T1, 0.94-0.95 for T2*, and 0.95-0.96 for χ. The cross-site wCV was 13.4 ± 5.47% for T1 and 3.69 ± 2.25% for T2*, and cross-site wSD of χ at 4.08 ± 3.22 ppb. The cross-site ICC(2,1) was 0.707, 0.913, and 0.902 for T1, T2*, and χ, respectively. QPM provides T1, T2*, and χ values with an intra-site repeatability of <12% and cross-site reproducibility of <14%. These findings may contribute to the development of multisite studies.

2.
Magn Reson Med Sci ; 2024 Feb 02.
Article in English | MEDLINE | ID: mdl-38311395

ABSTRACT

Gadoxetic acid is both an extracellular- and hepatocyte-specific contrast agent. Signals from the extracellular space may lower the contrast between lesions and the surrounding hepatic parenchyma. To improve hepatocyte-specific enhancement, we developed an intracellular contrast-enhancing fat-saturated T1-weighted gradient-echo nature of the sequence (ICE-TIGRE). It incorporates the motion-sensitized driven-equilibrium (MSDE) pulse to suppress signals from the blood flow. We investigated the optimal ICE-TIGRE scanning parameters, i.e., the order of the MSDE and the fat saturation pulses, the duration time, and the b value of the MSDE pulse, using a phantom and three volunteers without applying gadoxetic acid. ICE-TIGRE successfully increased the contrast between the liver parenchyma and the portal vein. To maintain fat saturation, the preparation pulse order should be MSDE-fat saturation. A duration time of 21 ms should be applied to minimize the effect of the T2 factor on the T1 contrast, and a b value of 60 s/mm2 should be applied to maximize the diffusion contrast for ICE-TIGRE with the imaging system used in this study.

3.
Magn Reson Med Sci ; 22(2): 241-252, 2023 Apr 01.
Article in English | MEDLINE | ID: mdl-35650028

ABSTRACT

PURPOSE: The wavelet denoising with geometry factor weighting (g-denoising) method can reduce the image noise by adapting to spatially varying noise levels induced by parallel imaging. The aim of this study was to investigate the clinical applicability of g-denoising on hepatobiliary-phase (HBP) images with gadoxetic acid. METHODS: We subjected 53 patients suspected of harboring hepatic neoplastic lesions to gadoxetic acid-enhanced HBP imaging with and without g-denoising (g+HBP and g-HBP). The matrix size was reduced for g+HBP images to avoid prolonging the scanning time. Two radiologists calculated the SNR, the portal vein-, and paraspinal muscle contrast-to-noise ratio (CNR) relative to the hepatic parenchyma (liver-to-portal vein- and liver-to-muscle CNR). Two other radiologists independently graded the sharpness of the liver edge, the visibility of intrahepatic vessels, the image noise, the homogeneity of liver parenchyma, and the overall image quality using a 5-point scale. Differences between g-HBP and g+HBP images were determined with the two-sided Wilcoxon signed-rank test. RESULTS: The liver-to-portal- and liver-to-muscle CNR and the SNR were significantly higher on g+HBP- than g-HBP images (P < 0.01), as was the qualitative score for the image noise, homogeneity of liver parenchyma, and overall image quality (P < 0.01). Although there were no significant differences in the scores for the sharpness of the liver edge or the score assigned for the visibility of intrahepatic vessels (P = 0.05, 0.43), with g+HBP the score was lower in three patients for the sharpness of the liver edge and in six patients for the visibility of intrahepatic vessels. CONCLUSION: At gadoxetic acid-enhanced HBP imaging, g-denoising yielded a better image quality than conventional HBP imaging although the anatomic details may be degraded.


Subject(s)
Contrast Media , Liver Neoplasms , Humans , Gadolinium DTPA , Liver/diagnostic imaging , Liver/pathology , Magnetic Resonance Imaging/methods , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/pathology , Retrospective Studies
4.
Magn Reson Imaging ; 94: 80-88, 2022 12.
Article in English | MEDLINE | ID: mdl-36122676

ABSTRACT

To develop and validate a novel noncontrast time-resolved magnetic resonance angiography (NC TR-MRA) using consecutive beam pulses with variable flip angles for visualizing hemodynamics in the pulmonary artery, we performed phantom and volunteer studies and applied the novel NC TR-MRA to a 51-year-old woman with pulmonary arteriovenous malformation (PAVM).The novel NC TR-MRA sequence utilized consecutive multiple-beam saturation pulses with variable flip angles considering venous blood T1 relaxation to alter the visualized blood signal length. The flowing blood signal length is suppressed according to the number of beam saturation pulses. NC TR-MRA in each flow phase was assessed by subtracting the images with and without beam saturation pulses. In the flow phantom study, three flow velocities were used to simulate physiological pulmonary arterial blood flow. Signal profiles along the flow direction were evaluated in each flow phase. In the volunteer study, five healthy volunteers were recruited, and NC TR-MRA was applied to evaluate relationships between the flow-saturated time and signal enhancement rates. Four regions of interest (ROIs) were determined on the proximal and distal portions of the right basal artery. A patient with PAVM was included to validate whether a PAVM lesion could be visualized using NC TR-MRA. The visualized flow signal lengths extended proportionally with the number of beam saturation pulses in the steady-flow phantom at all velocities. In the volunteer study, NC TR-MRA images showed signal enhancement from the proximal to distal portions of the right basal artery with increase in the flow-saturated time. Signal enhancement rates in all ROIs were significantly positively correlated with the flow-saturated time (p < 0.001 in all ROIs). Further, the lesion and its hemodynamics could be explicitly visualized in the patient with PAVM. Hence, NC TR-MRA using beam saturation pulse can visualize the hemodynamics of the pulmonary artery and may be useful for diagnosing and following patients with PAVM.


Subject(s)
Magnetic Resonance Angiography , Pulmonary Veins , Female , Humans , Middle Aged , Magnetic Resonance Angiography/methods , Pulmonary Veins/diagnostic imaging , Phantoms, Imaging , Pulmonary Artery/diagnostic imaging
5.
J Comput Assist Tomogr ; 45(3): 359-366, 2021.
Article in English | MEDLINE | ID: mdl-33661153

ABSTRACT

OBJECTIVES: This study aimed to compare the accuracy of assessing the arterial hypervascularity of hepatocellular carcinoma (HCC) on dynamic computed tomography (CT) scans and gadoxetic acid (EOB)-enhanced magnetic resonance imaging (MRI) scans performed with radial sampling. METHODS: We studied the images of 40 patients with hypervascular HCC. A radiologist recorded the standard deviation of the attenuation (or the signal intensity [SI]) in subcutaneous fat tissue as the image noise (N) and calculated the contrast-to-noise ratio (CNR) as follows: (CNR) = (n-ROIT - n-ROIL)/N, where n-ROIT is the mean attenuation (or SI) of the tumor divided by the mean attenuation (or SI) of the aorta and n-ROIL is the mean attenuation (or SI) of the liver parenchyma divided by the mean attenuation (or SI) of the aorta. RESULTS: The CNR was significantly higher on EOB-enhanced MRI than on dynamic CT scans. CONCLUSIONS: For the assessment of HCC vascularity, EOB-enhanced MRI scans acquired with radial sampling were more accurate than dynamic CT images.


Subject(s)
Angiography/methods , Carcinoma, Hepatocellular/blood supply , Gadolinium DTPA/administration & dosage , Hepatic Artery/diagnostic imaging , Liver Neoplasms/blood supply , Radiographic Image Interpretation, Computer-Assisted/methods , Aged , Aged, 80 and over , Carcinoma, Hepatocellular/diagnostic imaging , Female , Humans , Liver Neoplasms/diagnostic imaging , Magnetic Resonance Imaging , Male , Middle Aged , Retrospective Studies , Signal-To-Noise Ratio , Tomography, X-Ray Computed
6.
Magn Reson Imaging ; 73: 55-61, 2020 11.
Article in English | MEDLINE | ID: mdl-32853756

ABSTRACT

To clarify the temperature dependence of susceptibility estimated by quantitative susceptibility mapping (QSM) analysis, we investigated the relationship between temperature and susceptibility using a cylinder phantom with varying temperatures. Six solutions with various concentrations of superparamagnetic iron oxide (SPIO) nanoparticles were employed. These tubes were placed in a cylinder phantom and surrounded with water. The temperature of the circulated water was adjusted to change the temperature in the cylinder phantom from 25.8 °C to 42.5 °C. The cylinder phantom was scanned via a three-dimensional multiple spoiled gradient-echo sequence for R2* and QSM analyses with varying temperatures. The relationships between temperature, susceptibility, and R2* values were determined. Moreover, the temperature coefficients of susceptibility (χ-Tc) and (R2*-Tc) were calculated at each concentration and the linearities in these indices against each SPIO concentration were validated. Significant inverse correlations were found between temperature, susceptibility, and R2* values at each SPIO concentration due to the decrease in paramagnetic iron susceptibility that occurred with increasing temperature based on Curie's law. Moreover, although there were significant correlations between the susceptibility and R2* values at any temperature, the slopes of the regression lines grew in height with greater temperatures. The percentage of difference per Celsius degree in susceptibility in any SPIO concentration was lower than the corresponding finding among the R2* results. There were strong linearities between the SPIO concentration, χ-Tc (r = -0.994; p < 0.001), and R2*-Tc (r = -0.998; p < 0.001). The χ-Tc and R2*-Tc outcomes in a particular voxel varied considerably with the iron contents. Although there was an inverse correlation noted between temperature and susceptibility, the susceptibility analysis showed smaller temperature dependence relative to the R2* analysis. QSM analysis might be a more suitable option for magnetic resonance-based iron quantification in comparison with R2* relaxometry.


Subject(s)
Iron/analysis , Magnetic Resonance Imaging/instrumentation , Phantoms, Imaging , Temperature , Female , Humans , Image Processing, Computer-Assisted , Linear Models , Male
7.
Magn Reson Med Sci ; 19(1): 21-28, 2020 Feb 10.
Article in English | MEDLINE | ID: mdl-30880292

ABSTRACT

PURPOSE: Hepatobiliary-phase (HBP) MRI with gadoxetic acid facilitates the differentiation between lesions with and without functional hepatocytes. Thus, high-quality HBP images are required for the detection and evaluation of hepatic lesions. However, the long scan time may increase artifacts due to intestinal peristalsis, resulting in the loss of diagnostic information. Pseudo-random acquisition order disperses artifacts into the background. The aim of this study was to investigate the clinical applicability of pseudo-random trajectory scanning for the suppression of motion artifacts on T1-weighted images including HBP. METHODS: Our investigation included computer simulation, phantom experiments, and a clinical study. For computer simulation and phantom experiments a region of interest (ROI) was placed on the area with motion artifact and the standard deviation inside the ROI was measured as image noise. For clinical study we subjected 62 patients to gadoxetic acid-enhanced hepatobiliary-phase imaging with a circular- and a pseudo-random trajectory (c-HBP and p-HBP); two radiologists graded the motion artifacts, sharpness of the liver edge, visibility of intrahepatic vessels, and overall image quality using a five-point scale where 1 = unacceptable and 5 = excellent. Differences in the qualitative scores were determined using the two-sided Wilcoxon signed-rank test. RESULTS: The image noise was higher on the circular image compared with pseudo-random image (101.0 vs 60.9 on computer simulation image, 91.2 vs 67.7 on axial, 95.5 vs 86.9 on reformatted sagittal image for phantom experiments). For clinical study the score for motion artifacts was significantly higher with p-HBP than c-HBP imaging (left lobe: mean 3.4 vs 3.2, P < 0.01; right lobe: mean 3.6 vs 3.4, P < 0.01) as was the qualitative score for the overall image quality (mean 3.6 vs 3.3, P < 0.01). CONCLUSION: At gadoxetic acid-enhanced hepatobiliary-phase imaging, p-HBP scanning suppressed motion artifacts and yielded better image quality than c-HBP scanning.


Subject(s)
Gadolinium DTPA/chemistry , Image Processing, Computer-Assisted/methods , Liver/diagnostic imaging , Magnetic Resonance Imaging/methods , Artifacts , Computer Simulation , Humans , Phantoms, Imaging
8.
Int J Rheum Dis ; 22(8): 1489-1497, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31131563

ABSTRACT

AIM: The syndrome of periodic fever, aphthous stomatitis, pharyngitis, and cervical adenitis (PFAPA) is a common inflammatory disease that presents with periodic fever. We aimed to establish more specific diagnostic criteria for PFAPA based on the clinical characteristics of PFAPA patients in our directory. METHOD: The clinical, laboratory, genetic, and family history details of 257 Japanese PFAPA patients treated at our and other affiliated hospitals between April 2000 and April 2018 were analyzed along with quantitative measurements of the number of CD64 molecules on neutrophils, and the levels of serum inflammatory cytokines. The sensitivity and specificity of the criteria were calculated for several diseases. RESULTS: Because recurrent fevers were crucial findings, they were defined as the required criterion. Tonsillitis/pharyngitis with white moss were important accompanying signs. Other symptoms associated with febrile episodes were cervical lymphadenitis with tenderness, aphthous stomatitis, sore throat, vomiting, and headache but not cough. A total of 159 (62%) patients had a family history of recurrent fevers, indicating autosomal dominant inheritance. C-reactive protein levels were extremely elevated during febrile attacks but normal in attack-free periods. Serum immunoglobulin D levels were high in 72 of the 199 tested patients. Oral glucocorticoid and cimetidine were extremely effective in all and 51.6% of the patients, respectively. We defined the above as supportive criteria. These criteria were sensitive and specific enough to distinguish PFAPA from other recurrent fever diseases. Raised serum interferon-γ levels and remarkable CD64 expression on neutrophils during flare-ups were recognized, indicating they contributed to diagnosis. CONCLUSION: Our new criteria are useful for diagnosing PFAPA.


Subject(s)
Fever/diagnosis , Hereditary Autoinflammatory Diseases/diagnosis , Lymphadenitis/diagnosis , Pharyngitis/diagnosis , Stomatitis, Aphthous/diagnosis , Biomarkers/blood , Child, Preschool , Cytokines/blood , Female , Fever/blood , Fever/immunology , Fever/therapy , Glucocorticoids/therapeutic use , Hereditary Autoinflammatory Diseases/blood , Hereditary Autoinflammatory Diseases/immunology , Hereditary Autoinflammatory Diseases/therapy , Heredity , Histamine H2 Antagonists/therapeutic use , Humans , Infant , Inflammation Mediators/blood , Japan , Lymphadenitis/blood , Lymphadenitis/immunology , Lymphadenitis/therapy , Male , Membrane Cofactor Protein/blood , Neutrophils/immunology , Pedigree , Pharyngitis/blood , Pharyngitis/immunology , Pharyngitis/therapy , Predictive Value of Tests , Reproducibility of Results , Stomatitis, Aphthous/blood , Stomatitis, Aphthous/immunology , Stomatitis, Aphthous/therapy , Syndrome , Tonsillectomy , Treatment Outcome
9.
Magn Reson Med Sci ; 18(4): 276-285, 2019 Oct 15.
Article in English | MEDLINE | ID: mdl-30799332

ABSTRACT

To mitigate the susceptibility inhomogeneity induced by radio-frequency transmit phase error through the whole brain in quantitative susceptibility mapping (QSM) using single-echo gradient echo sequence, we developed a novel single-step QSM reconstruction algorithm and compared it with a previous algorithm in five healthy volunteers. The proposed algorithm had effectively suppressed the susceptibility inhomogeneity through the whole brain and achieved acceptable quality, similar to that of the susceptibility map calculated from a multi-echo gradient echo sequence.


Subject(s)
Brain Mapping/methods , Brain/diagnostic imaging , Image Processing, Computer-Assisted/methods , Signal Processing, Computer-Assisted , Algorithms , Humans , Magnetic Resonance Imaging
10.
Magn Reson Imaging ; 52: 94-101, 2018 10.
Article in English | MEDLINE | ID: mdl-29902566

ABSTRACT

PURPOSE: We developed a non-regularized, variable kernel, sophisticated harmonic artifact reduction for phase data (NR-VSHARP) method to accurately estimate local tissue fields without regularization for quantitative susceptibility mapping (QSM). We then used a digital brain phantom to evaluate the accuracy of the NR-VSHARP method, and compared it with the VSHARP and iterative spherical mean value (iSMV) methods through in vivo human brain experiments. MATERIALS AND METHODS: Our proposed NR-VSHARP method, which uses variable spherical mean value (SMV) kernels, minimizes L2 norms only within the volume of interest to reduce phase errors and save cortical information without regularization. In a numerical phantom study, relative local field and susceptibility map errors were determined using NR-VSHARP, VSHARP, and iSMV. Additionally, various background field elimination methods were used to image the human brain. RESULTS: In a numerical phantom study, the use of NR-VSHARP considerably reduced the relative local field and susceptibility map errors throughout a digital whole brain phantom, compared with VSHARP and iSMV. In the in vivo experiment, the NR-VSHARP-estimated local field could sufficiently achieve minimal boundary losses and phase error suppression throughout the brain. Moreover, the susceptibility map generated using NR-VSHARP minimized the occurrence of streaking artifacts caused by insufficient background field removal. CONCLUSION: Our proposed NR-VSHARP method yields minimal boundary losses and highly precise phase data. Our results suggest that this technique may facilitate high-quality QSM.


Subject(s)
Artifacts , Brain/diagnostic imaging , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Algorithms , Humans , Phantoms, Imaging , Reproducibility of Results
11.
Inflamm Res ; 65(7): 579-85, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27020279

ABSTRACT

OBJECTIVE: Kawasaki disease (KD) is the most commonly encountered inflammatory disease in children. However, its pathogenesis and diagnostic biomarkers have not been fully investigated. We examined the activation of neutrophils and monocytes in KD. METHODS: We studied the expression of the Fcγ-receptors CD64 and CD16 on neutrophils and monocytes in KD before and after the treatment with intravenous infusion of high dose immunoglobulin (IVIG). Bacterial infections were addressed as well. RESULTS: CD64 expression on neutrophils and monocytes was dramatically increased at the onset of KD flare-ups, but later decreased just after IVIG. Similarly, CD16-positive monocytes were observed at the onset and were less apparent after therapy. The addition of immunoglobulin did not block the expression of CD64 or CD16 in vitro. Serum G-CSF in the majority of patients, and IFN-γ in some patients, were elevated during flares but decreased after treatment. CONCLUSION: Our findings demonstrate that remarkable CD64 expression during KD flare-ups may serve as a biomarker for diagnosis. Evaluation of CD64 is also potentially useful for the determination of treatment efficacy in KD.


Subject(s)
Monocytes/metabolism , Mucocutaneous Lymph Node Syndrome/metabolism , Neutrophils/metabolism , Receptors, IgG/metabolism , Biomarkers/metabolism , Child, Preschool , Cytokines/blood , Female , Humans , Immunoglobulins, Intravenous/therapeutic use , Male , Monocytes/drug effects , Mucocutaneous Lymph Node Syndrome/blood , Mucocutaneous Lymph Node Syndrome/diagnosis , Mucocutaneous Lymph Node Syndrome/drug therapy , Neutrophils/drug effects
12.
IEEE Trans Med Imaging ; 32(2): 306-16, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23144030

ABSTRACT

Ultra-short TE (UTE) sequences with radial sampling make it possible to visualize tissues with very short T2 decay times. The UTE sequence acquires an echo signal from the central to the outer parts of k-space and is very sensitive to small trajectory errors. Therefore, k-space errors caused by imperfections in the gradient system performance, such as gradient delay and waveform distortion, must be corrected. During normal clinical use, these errors must be corrected to account for any gradient strength, or image obliquity. Because of time limitation on clinical examination, a simple, robust, and time-efficient correction method for use with UTE is needed. We demonstrated image degradation due to k-space errors by simulation and found that uncontrolled gradient time delays were the dominant cause of image degradation. They could be corrected by using a pre-scan calibration that works by comparison of half and full echo signals. Further improvements in image quality were achieved by using a one-time calibration of gradient waveform approximations that were built from multiple exponential functions and were used during image reconstruction. We have developed a robust UTE correction method that consists of a gradient waveform approximation that follows a short pre-scan for estimating gradient time delay errors.


Subject(s)
Algorithms , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Ultrasonography/methods , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity
13.
Fungal Genet Biol ; 47(1): 1-9, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19850146

ABSTRACT

Starch and maltooligosaccharides such as maltose and maltotriose induce the production of amylolytic enzymes including alpha-amylase in Aspergillus oryzae. A transcriptional activator gene amyR, required for maltose induction of amylolytic enzymes, has been cloned and characterized. The amyR gene deletion mutant showed significantly poor growth on starch medium but normal growth on maltose medium. This indicated the existence of another maltose-utilizing system, whose expression might not be controlled by amyR. We have identified a gene cluster homologous to the MAL cluster of Saccharomyces cerevisiae in the A. oryzae genome. The cluster consists of a MAL61 homolog (designated malP), a MAL62 homolog (designated malT), and a MAL63 homolog (designated malR). Overexpression of malT in A. oryzae resulted in a significant increase in intracellular alpha-glucosidase activity, and that of malP allowed S. cerevisiaemal61Delta to grow on maltose. The expression of both malP and malT genes was highly up-regulated in the presence of maltose, but malR expressed constitutively irrespective of carbon sources. Disruption of malR resulted in the loss of malP and malT expression and thus in restricted growth on maltose medium. In addition, a malP disruptant showed a significantly reduced expression of malT and malR and exhibited a growth defect on maltose similar to the malR disruptant. These results suggest that the MAL cluster of A. oryzae is responsible for the assimilation of maltose in A. oryzae.


Subject(s)
Aspergillus oryzae/metabolism , Fungal Proteins/metabolism , Gene Expression Regulation, Enzymologic , Gene Expression Regulation, Fungal , Maltose/metabolism , Multigene Family , Trans-Activators/metabolism , Amino Acid Sequence , Aspergillus oryzae/genetics , Aspergillus oryzae/growth & development , Fungal Proteins/genetics , Gene Deletion , Molecular Sequence Data , Monosaccharide Transport Proteins/genetics , Sequence Alignment , Trans-Activators/genetics
14.
Magn Reson Med Sci ; 8(4): 149-58, 2009.
Article in English | MEDLINE | ID: mdl-20035123

ABSTRACT

PURPOSE: Because radial sampling imposes many limitations on magnetic resonance (MR) imaging hardware, such as on the accuracy of the gradient magnetic field or the homogeneity of B(0), some correction of the echo signal is usually needed before image reconstruction. In our previous study, we developed an echo-peak-shift correction (EPSC) algorithm not easily affected by hardware performance. However, some artifacts remained in lung imaging, where tissue is almost absent, or in cardiac imaging, which is affected by blood flow. In this study, we modified the EPSC algorithm to improve the image quality of the radial aquisition regime (RADAR) and expand its application sequences. METHODS: We assumed the artifacts were mainly caused by errors in the phase map for EPSC and used a phantom on a 1.5-tesla (T) MR scanner to investigate whether to modify the EPSC algorithm. To evaluate the effectiveness of EPSC, we compared results from T(1)- and T(2)-weighted images of a volunteer's lung region using the current and modified EPSC. We then applied the modified EPSC to RADAR spin echo (SE) and RADAR balanced steady-state acquisition with rewound gradient echo (BASG) sequence. RESULTS: The modified EPSC reduced phase discontinuity in the reference data used for EPSC and improved visualization of blood vessels in the lungs. Motion and blood flow caused no visible artifacts in the resulting images in either RADAR SE or RADAR BASG sequence. CONCLUSION: Use of the modified EPSC eliminated artifacts caused by signal loss in the reference data for EPSC. In addition, the modified EPSC was applied to RADAR SE and RADAR BASG sequences.


Subject(s)
Algorithms , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Artifacts , Head/anatomy & histology , Humans , Kidney/anatomy & histology , Lung/anatomy & histology , Lung/blood supply , Lung/physiology , Magnetic Resonance Imaging/instrumentation , Motion , Phantoms, Imaging , Regional Blood Flow
15.
Magn Reson Med Sci ; 8(4): 175-80, 2009.
Article in English | MEDLINE | ID: mdl-20035126

ABSTRACT

Radial scanning is attracting increasing attention as a method of suppressing motion artifacts in magnetic resonance imaging. We compared the effectiveness of radial acquisition regime-fast spin echo (RADAR-FSE), a method of radial scanning, with conventional FSE in the T(1)-weighted imaging setting by scanning Gd-DTPA phantoms and 9 female patients (pelvic imaging). RADAR-FSE suppressed motion artifacts better than FSE but caused streak artifacts and diminished sharpness. Clinicians should be aware of these limitations.


Subject(s)
Magnetic Resonance Imaging/methods , Pelvis/anatomy & histology , Adult , Aged , Artifacts , Female , Gadolinium DTPA , Humans , Magnetic Resonance Imaging/instrumentation , Middle Aged , Motion , Ovary/anatomy & histology , Ovary/pathology , Pelvis/pathology , Phantoms, Imaging , Uterus/anatomy & histology , Uterus/pathology , Young Adult
16.
Hum Immunol ; 67(12): 966-75, 2006 Dec.
Article in English | MEDLINE | ID: mdl-17174745

ABSTRACT

IgD+CD27+ memory B cells are a major compartment of circulating memory B cells. However, the characteristics of these cells in the tonsils have been unclear. In this study, IgD+CD27+ memory B cells residing in the tonsillar marginal zone were found to exhibit similar characteristics as IgD+CD27+ memory B cells in the periphery, namely large morphology, expression of surface molecules, and hypermutated Ig variable region genes. Furthermore, these IgD+CD27+ memory B cells predominantly produced IgM, including IgM specific against pneumococcal polysaccharides. Taken together, these results provide convincing evidence that tonsillar IgD+CD27+ memory B cells impart protective humoral immunity against pneumococcal infection by producing high-affinity IgM.


Subject(s)
Antibody Formation , B-Lymphocytes/immunology , Immunoglobulin D/immunology , Immunologic Memory , Palatine Tonsil/immunology , Pneumococcal Infections/immunology , Tumor Necrosis Factor Receptor Superfamily, Member 7/immunology , Adolescent , Adult , Antibody Affinity/immunology , B-Lymphocytes/metabolism , Female , Humans , Immunoglobulin D/biosynthesis , Immunoglobulin M/biosynthesis , Immunoglobulin M/immunology , Male , Middle Aged , Palatine Tonsil/metabolism , Pneumococcal Infections/metabolism , Somatic Hypermutation, Immunoglobulin/immunology
17.
Magn Reson Med Sci ; 4(2): 95-101, 2005.
Article in English | MEDLINE | ID: mdl-16340164

ABSTRACT

BACKGROUND: Parallel imaging is widely used for cylindrical magnetic resonance imaging (MRI); however, few studies apply parallel imaging to open MRI. We previously developed a parallel method called "RAPID" (rapid acquisition through a parallel imaging design) for imaging the heart on a 0.7T open MRI apparatus, and we have now developed a RAPID head coil and shading correction algorithm for imaging the brain with a 0.4T open MRI apparatus. Images acquired with RAPID were compared with those acquired using a conventional quadrature-detection (QD) head coil. MATERIALS AND METHODS: The images were acquired using a dedicated 4-channel RF receiving coil consisting of a solenoid coil and surface coils. For MRI of the brain, we developed 2 methods to acquire the necessary calibration data: a pre-scan method that acquires the calibration data before the main scans and a self-calibration method that acquires the calibration data and imaging data simultaneously. We also modified the algorithm for calculating the shading distribution so that it only uses acquired image data and then corrects the shading. RESULTS: RAPID was applied for T1-weighted, T2-weighted, fluid-attenuation inversion recovery (FLAIR), time-of-flight (TOF), and diffusion-weighted echo-planar (DW-EPI) imaging. The RAPID images had no visible unfolded artifacts or motion artifacts. Images with the same contrast as that with a conventional QD coil were acquired using the RAPID coil and shading correction. CONCLUSION: These preliminary results show that RAPID can be applied to imaging of the head using a 0.4T open MRI apparatus.


Subject(s)
Brain Mapping/methods , Magnetic Resonance Imaging/methods , Algorithms , Equipment Design , Humans , Image Processing, Computer-Assisted , Magnetic Resonance Imaging/instrumentation , Phantoms, Imaging
18.
Magn Reson Med Sci ; 3(1): 45-9, 2004 Apr 01.
Article in English | MEDLINE | ID: mdl-16093619

ABSTRACT

BACKGROUND: Parallel imaging can be applied to cardiac imaging with a cylindrical MRI (magnetic resonance imaging) apparatus. Studies of open MRI, however, are few. This study sought to achieve cardiac cine parallel imaging (or RAPID, for "rapid acquisition through parallel imaging design") with an open 0.7T MRI apparatus. MATERIALS AND METHODS: Imaging time was shortened in all slice directions with the use of a dedicated four-channel RF receiving coil comprising solenoid coils and butterfly coils. Coil shape was designed through an RF-coil simulation that considered biological load. The auto-calibration of a 0.7T open MRI apparatus incorporated a modified image-domain reconstruction algorithm. Cine images were obtained with a BASG, or balanced SARGE (steady-state acquisition with rewound gradient echo), sequence. Image quality was evaluated with cylindrical phantoms and five healthy volunteers. RESULTS: Multi-slice phantom images showed no visible artifacts. Cine images taken under breath-hold with an acceleration factor of two were evaluated carefully. With auto-calibration, the images revealed no visible unfolded artifacts or motion artifacts. RAPID thus improved the acquisition speed, time resolution, and spatial resolution of short-axis, long-axis, and four-chamber images. CONCLUSION: The use of a dedicated RF coil enabled cardiac cine RAPID to be performed with an open MRI apparatus.


Subject(s)
Heart Diseases/diagnosis , Magnetic Resonance Imaging, Cine/instrumentation , Artifacts , Equipment Design , Humans , Phantoms, Imaging
19.
J Org Chem ; 63(20): 6929-6938, 1998 Oct 02.
Article in English | MEDLINE | ID: mdl-11672314

ABSTRACT

Lipase-catalyzed enantiomeric kinetic resolution of ceramides related to C(16)-sphinganine and C(18)-sphingenine is described. Two hydroxy groups in readily available racemic N-stearoyl-erythro-C(16)-sphinganine were acetylated, and several kinds of lipases were screened for the hydrolysis of this substrate. Among them, a Burkholderia cepacia lipase (SC lipase A, Sumitomo Chemical Co., Ltd.) showed the highest reactivity and enantioselectivity. The rate of hydrolysis and selectivity were greatly affected by some additives. Especially, the combined use of a detergent, Triton X-100, and the solid support, Florisil, for immobilization showed the highest enantioselectivity (E = ca. 170), although the reaction rate turned low. Introduction of a double bond into the substrate (N-stearoyl-erythro-C(18)-sphingenine) also retarded the hydrolysis. By utilizing the preferential hydrolysis of the acetate on the primary hydroxy group, another advantageous feature of this enzyme-catalyzed reaction, the resulting product could directly be used as the glycosyl acceptor for cerebroside synthesis.

SELECTION OF CITATIONS
SEARCH DETAIL
...