Lab Delo ; (12): 59-61, 1990.
Article in Russian | MEDLINE | ID: mdl-1710698

ABSTRACT

The suggested method for measuring blood plasma heparin is based on heparin ability to enhance antithrombin activity of antithrombin III (AT-III), the major Xa and thrombin inhibitor. The method consists in measurement of blood plasma AT-III activity in the presence and absence of protamine sulfate that destroys the heparin--AT-III complex. Heparin content in U/ml is determined from the difference in the activities of heparin--AT-III complex and AT-III proper activity represented on the calibration curve. The method is sufficiently sensitive, it permits registration of heparin concentrations in a wide band (from 0.01 U/ml to 0.75 U/ml of plasma).


Subject(s)
Antithrombin III/metabolism , Heparin/blood , Humans , Indicators and Reagents , Protamines