Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Pril (Makedon Akad Nauk Umet Odd Med Nauki) ; 44(2): 175-183, 2023 Jul 01.
Article in English | MEDLINE | ID: mdl-37453105

ABSTRACT

There is a growing incidence of new cases of venous thromboembolismworldwide.Some of these patients do have a predisposition to the development of thrombosis, some of them do however have various risk factors associated with this event, but few of them have unrecognized etiology. This paper aimsto describe different scenarios of venous thromboembolism.


Subject(s)
Venous Thromboembolism , Venous Thromboembolism/diagnosis , Humans , Thrombosis , Risk Factors
2.
Cureus ; 13(1): e12457, 2021 Jan 03.
Article in English | MEDLINE | ID: mdl-33552775

ABSTRACT

In the past several decades there has been a continuous growth in the field of cardiac implantable electronic devices (CIED) implantation procedures as well as their technological development. CIEDs utilize transvenous leads that are introduced into the heart via the axillary, subclavian, or cephalic veins, as well as a devices generator that is implanted in a subcutaneous pocket, typically in the pre-pectoral region. Despite this significant improvement, complication rates range from 1-6% with current implant tools and techniques. In this review we will discuss the three central parts of the CIED implantation procedure, their impact on implantation site, infections, and possibilities for its prevention.

3.
Acta Clin Croat ; 58(2): 391-393, 2019 Jun.
Article in English | MEDLINE | ID: mdl-31819339

ABSTRACT

We present a case of a 64-year-old female patient scheduled for implantable cardioverter defibrillator (ICD) implantation due to arrhythmogenic right ventricular cardiomyopathy (ARVC). Dual coil, active fixation ICD lead was introduced through the axillary vein. More than 20 positions were changed in the right ventricle (RV) (outflow tract, high, mid and apical septum, infero-basal, apical and lateral wall). Maximum R wave amplitude was 2 mV with pacing threshold of 0.5 V. Since the sensing was inappropriate, we decided to place the pace/sense lead of the ICD in the coronary sinus. The lead was placed in the basal part of the lateral vein. The pacing threshold was 1.0 V/0.40 ms and R wave was 9 mV. The lead was connected to the ICD sense-pace port and high voltage coils were connected in the usual way. The RV sense-pace lead was capped off. The device sensed an R wave of 7.0 mV 48 hours later. The purpose of this report is to show a possible solution of sensing problems during an ICD implantation in a patient with ARVC.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia/therapy , Defibrillators, Implantable , Prosthesis Implantation/methods , Defibrillators, Implantable/adverse effects , Female , Heart Ventricles , Humans , Middle Aged
4.
Open Access Maced J Med Sci ; 6(2): 297-302, 2018 Feb 15.
Article in English | MEDLINE | ID: mdl-29531592

ABSTRACT

INTRODUCTION: Although strict selection criteria are used to select patients for cardiac resynchronisation therapy, up to 30% of patients do not have a positive clinical response. PATIENTS: A total of 102 consecutive patients who had biventricular pacemaker/defibrillator (CRT-P or CRT-D) implanted were enrolled in this prospective observational study. RESULTS: During the average follow-up period of 24.3 months 5 patients died and 17 (16.7%) patients were hospitalised with the symptoms of heart failure; 75 (73.5%) patients were responders based on the previously defined criteria. Responders in the group of LBBB patients kept the significant difference in a computed variable (S1 + R6) - (S6 + R1) and R6/S6 ratio. Responders in non-LBBB patients kept the significant difference only in the height of R waves in V6. The R6/S6 ratio tended to be higher, but it did not reach a statistical significance. CONCLUSION: None of the tested ECG parameters stands out as an independent predictor of response to cardiac resynchronisation therapy, but some of them were different in responder-compared to the non-responder group. The amplitude of R wave in V6, higher R/S ratio in V6 and higher computed variable (S1 + R6) - (S6 + R1) may predict the likelihood of response to CRT therapy in both LBBB-patients and non-LBBB patients.

5.
J Innov Card Rhythm Manag ; 9(8): 3284-3290, 2018 Aug.
Article in English | MEDLINE | ID: mdl-32477819

ABSTRACT

The purpose of this study was to explore the usability of the cephalic vein (CV) for cardiac implantable electronic device (CIED) lead access by applying a scoring system to assess the venous anatomy. This prospective, single-center study included 100 consecutive patients who underwent CIED implantation within a period of one year. Contrast-enhanced venography images were obtained for every patient, focused on the CV, "T-junction," and the subclavian/axillary veins (SV/AVs). Though careful examination of the images, an angle, valves, diameter, noncollateral (AVDnC) score was constructed and used to aid in choosing a CV or SV/AV access approach; in all cases, however, the preferred approach was CV independent of the AVDnC score result obtained. Upon use of the scoring system, the majority of patients (54%) had type A score result (≥ 3), indicating a favorable anatomy for CV access. In 48 of these patients, the CV was used for the implantation of at least one lead. The remaining 46 (46%) patients had type B score result (≤ 2). In 41 patients from this group, SV/AV access was used for lead implantation and, in five patients, CV access was used. The number of leads introduced through the CV was associated with larger score and the operator's experience. In conclusion, in more than 50% of patients, at least one lead could be introduced through the CV. The scoring system used herein can simplify the choice between CV and SV/AV access and could eventually increase the efficiency and safety of the procedure, especially when less experienced implanters are involved.

6.
Open Access Maced J Med Sci ; 4(2): 243-7, 2016 Jun 15.
Article in English | MEDLINE | ID: mdl-27335594

ABSTRACT

INTRODUCTION: In patients with an implanted pacemaker, asymptomatic atrial fibrillation (AF) is associated with an increased risk of thrombo-embolic complications. There is still no consensus which duration of episodes of atrial fibrillation should be taken as an indicator for inclusion of oral anticoagulation therapy (OAC). MATERIAL AND METHODS: A total of 104 patients who had no AF episodes in the past and have an indication for permanent pacing were included in the study. RESULTS: During an average follow-up of 18 months, 33 of the patients developed episodes of AF. Inclusion of OAC was performed in 17 patients, in whom AF was recorded, although in all patients CHA2DS2-VASc score was ≥ 1. The inclusion of OAC showed a statistically significant correlation with increasing duration of episodes of AF (r = 0.502, p = 0.003). During the follow-up period none of the patients developed thrombo-embolic complication. CONCLUSION: Considering that our group of patients had no thrombo-embolic events, we could conclude that dividing the AF episodes in less than 1% in 24 hours and longer than 1% within 24 hours could be an indicator for decision-making to include OAK if the CHA2DS2-VASc score is ≥ 1.

7.
Arrhythm Electrophysiol Rev ; 3(3): 149-55, 2014 Nov.
Article in English | MEDLINE | ID: mdl-26835083

ABSTRACT

Orthotopic heart transplantation (OHT) is currently the most effective long-term therapy for patients with end-stage cardiac disease, even as left ventricular devices show markedly improved outcomes. As surgical techniques and immunosuppressive regimens have been refined, short-term mortality caused by sepsis has decreased, while morbidity caused by repeated rejection episodes and vasculopathy has increased, and is often manifested by arrhythmias. These chronic transplant complications require early and aggressive multidisciplinary treatment. Understanding the relationship between arrhythmias and these complications in the acute and chronic stages following OHT is critical in improving patient prognosis, as arrhythmias may be the earliest or sole presentation. Finally, decentralised/ denervated hearts represent a unique opportunity to investigate the underlying mechanisms of arrhythmias.

SELECTION OF CITATIONS
SEARCH DETAIL
...