Am J Cardiol ; 123(11): 1765-1771, 2019 06 01.
Article in English | MEDLINE | ID: mdl-30926144

ABSTRACT

PROMUS Element (PE) Plus post-approval study was a large prospective, observational, all-comers study designed to evaluate the safety and performance of a thin-strut platinum chromium everolimus-eluting PE Plus stent in everyday clinical practice. A total of 2,683 "real-world" patients with limited clinical or anatomic exclusion criteria were enrolled at 52 clinical sites in the United States. The study met its primary end point of 12-month cardiac death or myocardial infarction (CD/MI) compared with a prespecified performance goal (p <0.0001). Five-year clinical outcomes were evaluated in overall PE Plus post-approval study patients and high-risk subgroups. During the 5-year follow-up period, CD/MI and stent thrombosis related to the PE Plus stent occurred in 9% and 2.2% overall patients, respectively. The reported all-cause mortality rate was 15%, with 7% classified as cardiac-related. A total of 18% patients underwent target vessel revascularization, and 11% were reported as target lesion revascularization. The rates of PE Plus stent-related CD/MI remained low in patients with medically treated diabetes (13%), small vessels (9%), and long stents (10%). PE Plus stent-related thrombosis through 5 years in patients with diabetes, small vessels and long stents was 4.2%, 2.2%, and 2.6%, respectively. The occurrence of target lesion revascularization was numerically higher in patients with diabetes (16%) and long lesions (18%) than the small vessels subgroup (11%). In conclusion, the final 5-year results establish the long-term safety and efficacy of the PE Plus stent in a broad, unselected patient population representative of "real-world" clinical practice.


Subject(s)
Coronary Artery Disease/therapy , Drug-Eluting Stents , Everolimus/administration & dosage , Chromium , Combined Modality Therapy , Female , Humans , Male , Platinum , Prospective Studies , Prosthesis Design , Time Factors , Treatment Outcome , United States
2.
Am J Cardiol ; 117(4): 539-545, 2016 Feb 15.
Article in English | MEDLINE | ID: mdl-26732420

ABSTRACT

The PROMUS Element Plus US Post-Approval Study (PE-Plus PAS) was a prospective, open-label, multicenter, observational study designed to examine outcomes in everyday clinical practice in patients treated with everolimus-eluting, platinum-chromium PROMUS Element Plus stents at 52 centers in the United States. This is the first report of results from this large study. The primary end point of the PE-Plus PAS was 12-month cardiac death or myocardial infarction in the more restricted population of "PLATINUM-like" patients pooled from the PE-Plus PAS, PE-PROVE (PROMUS Element European post-approval study), and PLATINUM Workhorse/Small Vessel trials. Additional clinical end points were tested in the overall PE-Plus PAS patient population. Of the 2,683 patients enrolled in PE-Plus PAS, 70% were men, mean age was 64 years, 33% had diabetes, and 29% were "PLATINUM-like." Among the PLATINUM-like patients, 12-month cardiac death or myocardial infarction was 1.8% (33 of 1,855) with an upper 1-sided 95% confidence interval of 2.3%, which was significantly less than the prespecified performance goal of 3.2% (pnoninferiority <0.001). In the overall PE-Plus population, 12-month target vessel failure (defined as death, MI, or revascularization related to the target vessel) was 6.7% (170 of 2,554), cardiac death was 1.4% (37 of 2,554), MI was 1.1% (28 of 2,554), and ARC-definite/probable stent thrombosis was 0.7% (19 of 2,554). A prespecified secondary end point of 12-month target vessel failure in diabetic patients demonstrated a rate of 4.2% (14 of 332) with an upper 1-sided 95% confidence interval of 6.03%, which was significantly less than the performance goal of 12.6% (pnoninferiority <0.001). In conclusion, in this large registry of unselected patients, coronary artery revascularization with the PROMUS Element Plus everolimus-eluting stent demonstrates favorable results with low 1-year clinical event rates.


Subject(s)
Chromium , Coronary Artery Disease/surgery , Device Approval , Drug-Eluting Stents , Percutaneous Coronary Intervention/methods , Platinum , Sirolimus/pharmacology , Adult , Aged , Aged, 80 and over , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Female , Follow-Up Studies , Humans , Immunosuppressive Agents/pharmacology , Male , Middle Aged , Prospective Studies , Prosthesis Design , Registries , Time Factors , Treatment Outcome , United States
3.
J Interv Cardiol ; 25(6): 565-75, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22998355

ABSTRACT

OBJECTIVES: This 2-year follow-up of the XIENCE V USA study examines both the long-term safety and effectiveness of the everolimus-eluting coronary stent system (EECSS) in real-world patients. BACKGROUND: The safety and effectiveness of EECSS at 1 year in real-world clinical settings have been demonstrated in XIENCE V USA trial with low rates of target lesion revascularization (TLR), cardiac death, myocardial infarction (MI), and stent thrombosis (ST). Data on whether efficacy is maintained after 1 year and the event rate of very late stent thrombosis (VLST) between 1 and 2 years have not yet been reported. METHODS: XIENCE V USA is a prospective, multicenter, single-arm, FDA required condition of approval study designed to examine the safety and effectiveness of EECSS in an all-inclusive, consecutively enrolled population from real-world clinical settings. Clinical end-point events, including ST, cardiac death, MI, and revascularization were adjudicated by an independent Clinical Events Committee. RESULTS: Four thousand eight hundred and seventy-three (96.4%) out of 5,054 participants (1,875 standard-risk; 3,059 extended-risk) reached 2-year follow-up. The 2-year rate of Academic Research Consortium (ARC)-defined definite and probable ST was 0.96% (95% CI 0.70-1.28) in the overall population and 0.34% (95% CI 0.12-0.74) and 1.33% (95% CI 0.95-1.81) in the standard-risk and extended-risk cohorts, respectively. The rate of VLST was 0.06% in the overall population, 0.0% in the standard-risk, and 0.10% in the extended-risk cohorts. The 2-year composite rate of cardiac death and ARC-defined MI was 8.9% (95% CI 8.08-9.70) in the overall population and 5.6% (95% CI 4.61-6.78) and 10.8% (95% CI 9.71-11.94) in the standard-risk and extended-risk cohorts, respectively. CONCLUSION: Low event rates observed at 1 year were maintained through 2 years. Despite the increased number of patients who discontinued dual antiplatelet therapy by 2 years, the ST rate remained consistently low, and <1% at 2 years due to low VLST occurrence. These results demonstrate continued safety and effectiveness of the XIENCE V everolimus-eluting stent in a highly complex, real-world patient population through 2 years.


Subject(s)
Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Sirolimus/analogs & derivatives , Angioplasty, Balloon, Coronary , Everolimus , Female , Humans , Male , Middle Aged , Myocardial Infarction/epidemiology , Prospective Studies , Sirolimus/administration & dosage , Thrombosis/epidemiology , United States/epidemiology
4.
JACC Cardiovasc Interv ; 4(12): 1298-309, 2011 Dec.
Article in English | MEDLINE | ID: mdl-22192371

ABSTRACT

OBJECTIVES: The XIENCE V USA (XIENCE V Everolimus Eluting Coronary Stent System Condition-of-Approval Post-Market study) sought to: 1) evaluate the safety of everolimus-eluting coronary stent systems (EECSS) in a contemporary cohort of real-world subjects; and 2) prospectively test the quality of event reporting with analysis of matched patients from the randomized SPIRIT IV (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions) trial. BACKGROUND: Randomized trials have demonstrated the safety and efficacy of EECSS in selected "standard-risk" patients. METHODS: The XIENCE V USA trial was a prospective, multicenter, single-arm study in unselected patients. The primary endpoint was Academic Research Consortium (ARC)-defined definite and probable stent thrombosis (ST); the co-primary endpoint was the composite of cardiac death and myocardial infarction at 1 year. Secondary analyses included: 1) stratification by standard-risk and extended-risk cohorts; and 2) late ST after dual antiplatelet therapy interruption. RESULTS: Of 5,054 participants (1,875 standard-risk; 3,179 extended-risk), 4,958 (98.1%) reached 1-year follow-up. The rate of ARC-defined definite and probable ST was 0.84% (95% confidence interval [CI]: 0.60% to 1.14%) in the overall population and 0.33% (95% CI: 0.12% to 10.72%) and 1.14% (95% CI: 0.80% to 11.58%) in the standard-risk and extended-risk cohorts, respectively. No late ST was observed after dual antiplatelet therapy interruption in either cohort after 6 months. The composite rate of cardiac death and ARC-defined myocardial infarction was 6.5% (95% CI: 5.79% to 17.17%) in the overall population, 3.8% (95% CI: 2.98% to 14.78%) in the standard-risk cohort, and 8.0% (95% CI: 7.09% to 19.02%) in the extended-risk cohort. CONCLUSIONS: This study comprehensively reports ST rates for EECSS in a contemporary real-world population. The absence of ST after dual antiplatelet therapy interruption beyond 6 months in standard-risk and high-risk patients is notable. Consistent safety outcomes between matched standard-risk cohorts from the XIENCE V USA study and the SPIRIT IV randomized trial suggest that this study affords a reliable benchmark for understanding the safety of EECSS in the context of real-world clinical practice. (XIENCE V Everolimus Eluting Coronary Stent System [EECSS] USA Post-Approval Study; NCT00676520).


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Sirolimus/analogs & derivatives , Aged , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/mortality , Benchmarking , Coronary Artery Disease/mortality , Device Approval/standards , Everolimus , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/etiology , Platelet Aggregation Inhibitors/administration & dosage , Product Surveillance, Postmarketing/standards , Prospective Studies , Prosthesis Design , Risk Assessment , Risk Factors , Sirolimus/administration & dosage , Thrombosis/etiology , Time Factors , Treatment Outcome , United States
SELECTION OF CITATIONS