Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Open Heart ; 7(2)2020 09.
Article in English | MEDLINE | ID: mdl-32994355

ABSTRACT

With rising focus on interventional treatment of the tricuspid valve (TV), the need for good echocardiographic imaging increases. Aim of this study was to develop a scoring system describing how accurate three dimensional (3D) echocardiographic imaging of TV and its anatomical structures is. METHODS AND RESULTS: In this retrospective exploratory cohort study, we analysed data from consecutive patients undergoing transoesophageal echocardiography (TOE) and transthoracic echocardiography (TTE). 3D sequences were stored using eight different views. In each view, scoring focused on visualisation of five (in TOE 6) anatomical structures with a maximum of three points per structure for excellent imaging quality. We compared the scores of patients with and without relevant tricuspid regurgitation (TR) (cut-off effective regurgitant orifice 0.4 cm² measured in two-dimensional (2D) TTE using velocity time integral and proximal isovolumetric velocity area). 108 consecutive patients were examined, 40.7% presented with relevant TR. With the exception of coaptation, a higher score was achieved for all structures in TOE than in TTE. TV ring (TVR) was easiest to visualise with TOE in four-chamber view (4 CV) (2.42±0.67 points) presenting the highest score independent of anatomical structure and view. Posterior leaflet had best imaging scores in TOE in 4 CV (2.0±0.86) compared with TTE in 4 CV (1.64±0.80), p=0.001. Patients with relevant TR had significantly better 3D imaging scores in 4 CV compared with patients without relevant TR (TTE p<0.013, TOE p<0.002). CONCLUSION: 4 CV delivers the most detailed information in TTE, whereas multiple views deliver good scores in TOE. As TVR is easiest to visualise, most of the patients would be suitable for a ring-based echocardiography-guided intervention. The score enables a standardised comparison of image quality.


Subject(s)
Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve/diagnostic imaging , Aged , Aged, 80 and over , Female , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies , Tricuspid Valve/physiopathology , Tricuspid Valve Insufficiency/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...